DOMUSFIRE C17-C24
65
Signalling
Fault
Possible causes
Cures
AL 8
NO NEG
PRESS
-In the work stage the boiler
detects a pressure below the
vacuum switch setting threshold.
-The system is stopped.
-The combustion chamber is dirty.
-The fume duct is obstructed.
-The fire door is not closed.
-The overpressure valves are
open-stuck.
-Faulty vacuum switch.
-Check cleanness of the fume
duct and combustion chamber.
-Check hermetic closing of the
door.
-Check closing of the
overpressure valves.
-Other reinstatement operations
must be carried out by a service
centre.
AL 9
INSUFF
DRAUGHT
-Appears when the combustion
air flow is below a certain
threshold.
-The combustion chamber is dirty.
-The fume duct is obstructed.
-The fire door is not closed.
-The overpressure valves are
open-stuck.
-Faulty air flow meter.
-Check cleanness of the fume
duct and combustion chamber.
-Check hermetic closing of the
door.
-Check
closing
of
the
overpressure valves.
-Other reinstatement operations
must be carried out by a service
centre.
AL E
WATER
PRESSURE
-Occurs when the water pressure
does not come within the values
for correct operation.
-The system is stopped.
-Occurs when the pressure
transducer on the water circuit
detects a pressure below or
above the fixed limits.
-Check the cause of the problem,
restoring the circuit pressure by
bringing it to the normal operating
value.
AL A
SAFETY
H
2
O
-Occurs in case of cutting in
heating chamber water
temperature safety thermostat.
-The system is stopped.
-The
safety
thermostat
has
detected a temperature above
the setting threshold due to
overheating
of
the
heating
chamber
water
blocking
gearmotor operation.
-Check the cause of excessive
overheating.
-Reset the relevant safety
thermostat by pressing the reset
button.
AL b
AUG TRIAC
ERROR
-Occurs when the gearmotor
works continuously and for more
than 60 sec.
-The system is stopped.
-The controller detects a faulty
gearmotor control relay (contacts
stuck).
-Reinstatement operations must
be carried out by a service centre.
Al c
WATER
PROBE
-Occurs in case of water T
detection probe
fault,
displaying T H2O = 0 °C.
- The shutdown procedure
is activated.
-Faulty probe
-The probe is disconnected from
the board.
-Reinstatement operations must
be carried out by a service centre.
AL d
HOT
WATER
-Occurs when the water
temperature has exceeded the
fixed limits.
-The system is stopped.
-Occurs when the temperature
probe in the heating chamber
detects a value above 92°C.
-Check the cause of the problem,
restoring the temperature by
bringing it to the normal operating
value.
AWAITING
COOL
-Occurs on relighting the boiler
immediately after having shut it
down.
-Reset attempt in shutdown stage
with boiler hot in cooling stage.
-Alarm reset is possible only after
shutdown.
AIRFLOW
METER
FAILURE
-Occurs when the air flow meter is
disconnected.
-The controller does not detect
the amount of combustion air
and does not shut down the
boiler; it only excludes the air
flow meter functions.
-Reinstatement operations must
be carried out by a service
centre.
FROST RISK
-Occurs when the water
temperature falls below a certain
value.
-The boiler controller detects the
water temperature below 6°C
and displays a message.
-The pump starts in order to move
the water inside the heating
circuit.
- Monitor the water temperature
so that it does not fall below 0°C.
SERVICE
DUE
-Occurs when the boiler has
exceeded 1800 hours of
operation since the previous
servicing.
-Extraordinary
maintenance
notice.
- Cleaning - extraordinary
maintenance and reinstatement
operations must be carried out by
an authorised service centre.
The Manufacturer reserves the right to make technical or aesthetic changes to the products at any time without notice.
The drawings, measurements, diagrams and any other configurations are given only by way of example.
Содержание DOMUSFIRE C17
Страница 3: ...DOMUSFIRE C17 C24 3 ...
Страница 8: ...DOMUSFIRE C17 C24 8 Dati tecnici caldaia ...
Страница 9: ...DOMUSFIRE C17 C24 9 Ingombri Caldaia a pellet mod DOMUSFIRE C17 DOMUSFIRE C24 ...
Страница 15: ...DOMUSFIRE C17 C24 15 2 7 Schema elettrico ...
Страница 36: ...DOMUSFIRE C17 C24 36 8 ALLEGATI ...
Страница 66: ...DOMUSFIRE C17 C24 66 8 ENCLOSURES ...
Страница 70: ...DOMUSFIRE C17 C24 70 Caractéristiques techniques de la chaudière ...
Страница 98: ...DOMUSFIRE C17 C24 98 8 ANNEXES ...
Страница 102: ...DOMUSFIRE C17 C24 102 Technische Daten des Kessels ...
Страница 129: ...DOMUSFIRE C17 C24 129 8 ANHÄNGE ...
Страница 133: ...DOMUSFIRE C17 C24 133 Datos técnicos de la caldera mod DOMUSFIRE C17 C24 ...