English
6
1.4 FUNCTIONS AND CONNECTIONS
During the navigation trough different modes, the user will be able to detect the mode
to be selected through lighting of LEDs involved, which will flash simultaneously. In
addition, in this mode, LEDs of the possible errors to be detected will light up.
Connections:
Warning:
To prevent possible errors, ensure that you have selected the correct mode
for the desired connection.
To connect Jaltest SST device to sensor or ECU, the multipin kit should be used as
follows:
Function table:
* Depending on the vehicle mode, it may be necessary to connect the device ground to the vehicle chassis (see
).
Note:
An incorrect connection cannot damage the device, since it is protected against polarity inversion.
Jaltest SST
Jaltest SST
connector
connector
Function
Connect to ACTIVE sensor
Connect to PASSIVE sensor
Simulation
Read
Simulation
Read
Red
Sensor power
supply (+)
YES
YES
YES
YES
Black
Ground (-)
YES
YES
NO*
NO
Blue
SIGNAL
YES
YES
YES
YES
DEVICE STATUS
SHORT PRESS
LONG PRESS
EXTRA-LONG PRESS
OFF
START MODE
-
-
START MODE
CHANGE TO
«ACTIVE SENSOR READ
SELECTION» MODE
-
IT TURNS OFF THE DEVICE
«ACTIVE SENSOR READ
SELECTION» MODE
CHANGE TO
«PASSIVE SENSOR READ
SELECTION» MODE
CHANGE TO
CHANGE TO
«ACTIVE SENSOR READ»
«ACTIVE SENSOR READ»
MODE
MODE
IT TURNS OFF THE DEVICE
«PASSIVE SENSOR READ
SELECTION» MODE
CHANGE TO «ACTIVE SENSOR
SIMULATION SELECTION»
MODE
CHANGE TO
CHANGE TO
«PASSIVE SENSOR READ»
«PASSIVE SENSOR READ»
MODE
MODE
IT TURNS OFF THE DEVICE
«ACTIVE SENSOR
SIMULATION SELECTION»
MODE
CHANGE TO «PASSIVE
SENSOR SIMULATION
SELECTION» MODE
CHANGE TO
CHANGE TO
«ACTIVE SENSOR
«ACTIVE SENSOR
SIMULATION» MODE
SIMULATION» MODE
IT TURNS OFF THE DEVICE
«PASSIVE SENSOR
SIMULATION SELECTION»
MODE
CHANGE TO
«ACTIVE SENSOR READ
SELECTION» MODE
CHANGE TO
CHANGE TO
«PASSIVE SENSOR
«PASSIVE SENSOR
SIMULATION» MODE
SIMULATION» MODE
IT TURNS OFF THE DEVICE
«ACTIVE SENSOR READ»
MODE
IT RESETS
PRESENT ERRORS
CHANGE TO
«START» MODE
IT TURNS OFF THE DEVICE
«PASSIVE SENSOR READ»
MODE
IT RESETS
PRESENT ERRORS
CHANGE TO
«START» MODE
IT TURNS OFF THE DEVICE
«ACTIVE SENSOR
SIMULATION» MODE
IT CHANGES SIGNAL
FREQUENCY AND RESETS
PRESENT ERRORS
CHANGE TO
«START» MODE
IT TURNS OFF THE DEVICE
«PASSIVE SENSOR
SIMULATION» MODE
IT CHANGES SIGNAL
FREQUENCY AND RESETS
PRESENT ERRORS
CHANGE TO
«START» MODE
IT TURNS OFF THE DEVICE
Содержание Jaltest SST
Страница 1: ...Jaltest SST Speed Sensor Tester User manual ...
Страница 2: ...Jaltest SST Speed Sensor Tester User manual Rev 01 ...
Страница 15: ...2020 V 1 EN ...