Power to the base station can be supplied by either the DC power plug or by wiring in 24V.

DO NOT

use both in

parallel. The DC power plug is a 24VDC power supply (DMA-24VPWR-xx), 3.5 mm x 1.3 mm.

Note

: Be careful to use the appropriate connector for RS-232. See

Step 6

above.

7. When the base station is powered up, scan the Pair scan code and place your reader into the base station. The

base station’s status indicator becomes green. When the wireless reader is removed from the base, a wireless

connection is established. The status indicator of both the base station and the reader become blue and you can

hear a beep. Blue lights indicate that the reader and the base have successfully paired and are communicating.

8. Connect to your base station or to the wireless reader. You have the following connection options:

Base Station Connection Type

Connect to Reader in the DataMan Setup Tool

Connection Channels

RS-232

Wireless reader appears: COM port

(Base Station does not appear)

terminal program

Setup Tool

USB

Base Station appears: COM port 1

Wireless reader appears: COM port 2

terminal program

Setup Tool

Ethernet

Base station appears: Network device 1

Wireless reader appears: Network device 2

terminal program

Setup Tool

9. Lift your reader up from the base station and start reading codes.

Note

:

l

When the reader is on the base station, communication is established by means of cradle contacts. Wireless

communication is disabled.

l

Configure wireless communication settings by connecting to the base station. In order for the changed

settings to be synchronized between the DataMan 8600 wireless reader and the base station, place your

reader in the base station after your changes are saved. To assign a static IP address to the base station or

the reader when communicating via Ethernet, connect to the base station in the DataMan Setup Tool. The

base station, however, auto-assigns the IP address to the reader when they become paired.

l

When you connect with the base station to a terminal program, your wireless reader sends decode results to

the terminal, but you cannot send commands to the reader.

l

If you want to unpair your reader from the base station, you can either click Unassign in the Bluetooth or

Wireless tab of the

Communication Settings

pane of the DataMan Setup Tool (when you are connected

either with the reader or the base station), or scan the “Unassign Reader” reader configuration code.

l

If you place the wrong reader (that is, a reader that is not associated with the base station) into the base

station, the base station status indicator flashes red and a series of short beeps can be heard.

Pairing Strategy (DMA-IBASE-BT-XX)

In order to pair the base station and the reader in a single step without considering former pairing states and without

using the DataMan Setup Tool, scan the Pair sticker from the scan code sticker on the base station. Place the reader in

the base station.

23

Connection Options

Содержание DataMan 8600 Series

Страница 1: ...DataMan 8600 Reference Manual 2019October08 Revision 6 1 6SR1 5...

Страница 2: ...y means electronic or mechanical for any purpose nor transferred to any other media or language without the written permission of Cognex Corporation Copyright 2019 Cognex Corporation All Rights Reserv...

Страница 3: ...onnecting a DataMan 8600 Through Ethernet 16 Troubleshooting an Ethernet Connection 17 Connecting a DataMan 8600 Through RS 232 17 Connecting a DataMan 8600 Through USB 19 Using Your Device Through US...

Страница 4: ...37 Laser Information 37 Regulations Conformity 37 Compliance Statements DataMan Base Station 39 RoHS Information for China RoHS Compliance 41 Reader Control Codes 42 Keyboard Language Corded Readers...

Страница 5: ...a hazard that could cause death serious personal injury or electrical shock CAUTION This symbol indicates a hazard that could result in property damage Note This symbol indicates additional informatio...

Страница 6: ...proof modular communication slide ins The DataMan 8600 readers use Cognex s patented UltraLight technology and 2DMax algorithms to read the most challenging Direct Part Mark barcodes UltraLight illumi...

Страница 7: ...BT 02 DMA IBASE 01 DataMan 8600 Accessories DataMan 8600 Other Accessories Serial USB slide in DMCM SERIALM 00 Ethernet slide in DMCM ENETM 00 Bluetooth slide in DMCM BTM 00 Wireless slide in DMCM WL...

Страница 8: ...taMan 8600 Reader Cables RS 232 coiled cable for reader 2 5 m DM8000 RS232 02 RS 232 industrial cable for reader 2 5 m DM8000 RS232IND 02 RS 232 coiled cable for reader 4 m DM8000 RS232 05 USB cable 2...

Страница 9: ...e Station Cables RJ25 RJ12 to DSUB9 cable for base station 5 m DMA RS232RJ 05 Straight 10ft USB cable DMA USB 00 l USB cable for base station Use any standard USB A to USB B 2 0 cable up to 3 meters l...

Страница 10: ...igger is pressed to read a code the lights cycle performing a burst trigger through the enabled Read Setups then the flashing stops A beep and solid green light signifies that tuning is over and the r...

Страница 11: ...er 3 Spare battery charger status indicator 4 Connection point with the reader l pairing reader and base station l non wireless communication l charging 5 RS 232 6 USB 7 Power plug 24V max 13W 8 Ether...

Страница 12: ...astic part near the connector Recommended wire diameter is 14 18 AWG 7 Ethernet Base station status indicators l Power RED base powered BLINK wrong reader in base l Communication BLUE Wireless link BL...

Страница 13: ...Reader To be able to connect to your reader or base station on your computer you must perform the following steps 1 Install the DataMan Setup Tool on your computer 2 Select the connection type Etherne...

Страница 14: ...S1 DataBar Postal UPC EAN JAN DataBar 2 D barcodes Data MatrixTM QR Code and microQR Code RSS CS PDF 417 MicroPDF 417 Power Supply Requirements USB external 5 0 W maximum LPS or NEC class 2 power supp...

Страница 15: ...40 C 32 F 104 F Storage Temperature 40 C 60 C 40 F 140 F 40 C 60 C 40 F 140 F Maximum Humidity 95 non condensing 95 non condensing Power Supply Requirements 24V 10 15 W maximum LPS or NEC class 2 powe...

Страница 16: ...that the slide in is firmly locked 3 Insert the plug and slide the cable lock up to the reader and twist the cable lock in place Use the DM8000 ECABLE 05 5 meters or the DM8000 ECABLE 30 30 meters Yo...

Страница 17: ...e reader still does not appear you can use either the Add Device or Force Network Settings options in the DataMan Setup Tool 1 If you know the IP address of the reader use the Add Network Device optio...

Страница 18: ...PWR 000 Note Disconnect the DataMan 8600 reader from power before inserting removing the communication modules Observe the following electrical requirements 1 6VDC power supply DM100 PWR 000 a 5 5 mm...

Страница 19: ...the reader and twist the cable lock in place Use the DM8500 USB 00 cable 2 5 meters or the DM8500 USBC 02 cable 2 5 meters Note Disconnect the DataMan 8600 reader from power before inserting removing...

Страница 20: ...llowing steps In the case of a corded reader 1 Disconnect from the DataMan Setup Tool if you are connected 2 Scan the USB Keyboard code from the DataMan Configuration Codes document 3 Start scanning c...

Страница 21: ...n 1 Connect the wireless slide in DMCM BTM 00 to your DataMan 8600 2 With a 2 5 mm Allen wrench tighten the screws so that the slide in is firmly locked 3 Insert the battery Note Remove the battery fr...

Страница 22: ...hernet adapter 6 Connect your base station to your PC using either serial USB or Ethernet communication DMA IBASE BT XX DMA IBASE 01 1 RS 232 connection 2 USB connection 3 Power 4 Alternative power su...

Страница 23: ...hed by means of cradle contacts Wireless communication is disabled l Configure wireless communication settings by connecting to the base station In order for the changed settings to be synchronized be...

Страница 24: ...d the reader put on it into force pairing mode This means that the reader and the base it is put on get paired regardless of any assignments they both had previously This force pairing mode is valid f...

Страница 25: ...e appears under WiFi connections connect to it with the DataMan Setup Tool and then use the Wireless tab under Communication Settings to configure authentication and encryption which are not configure...

Страница 26: ...DataMan Setup Tool connected to the base station under the Communication Settings Wireless tab if the reader has already been placed in the base station l Placing the reader in the intelligent base s...

Страница 27: ...stage page in the DataMan Setup Tool and check the IP address of the reader in the Address column USB Keyboard Open the text editor or your program of choice to use keyboard emulation When you return...

Страница 28: ...ndicator Reader Status Indicator Base Station Sounds Reader in wireless range of base station When the ireader s awake blinking blue indicates wireless connection with the base When the reader is offl...

Страница 29: ...nd then white No read red default Reader offline steady red Good read long beep No read no beep Wireless Reader Charging When you are reading codes with your wireless reader blinking red status indica...

Страница 30: ...ow flashing red indicators steady blue indicating connection flashing blue indicating data transfer Reader is charging in the base station steady red indicators steady green indicating connection flas...

Страница 31: ...The battery used in these devices may present a risk of fire or chemical burn if mistreated Do not disassemble heat above 60 C 140 F or incinerate Replace battery with Cognex DMA HHBATTERY 01 only The...

Страница 32: ...cked 5 If using DMA CBASE 01 place the battery in the spare battery charger in the direction of the small triangle of the battery When you are charging the auxiliary battery the base station s spare b...

Страница 33: ...6 Dispose of used battery promptly Keep it away from children Do not disassemble and do not burn it Use the appropriate separate take back systems for battery disposal 33 Connection Options...

Страница 34: ...ble Industrial Protocols Using either method a reboot is required for the changes to come into effect l Enable the protocols using the Industrial Protocols pane of the DataMan Setup Tool under Communi...

Страница 35: ...or you release the button Note that while in Presentation mode as the operator pulls the trigger the reader switches to Manual mode until the device is re docked into the base station Setup Tool conti...

Страница 36: ...th harsh or corrosive solvents including lye methyl ethyl ketone MEK or gasoline Cleaning the Reader Lens Cover To remove dust from the lens cover use a pressurized air duster The air must be free of...

Страница 37: ...h 650 nm Laser Power for classification 1 mW Beam Diameter 3 mm at aperture Divergence 5 mrad For assistance contact Cognex Corporation at http support cognex com Regulations Conformity The DataMan 86...

Страница 38: ...n a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference t...

Страница 39: ...d not be disposed of along with municipal waste and invites you to use the appropriate separate take back systems for product disposal If you need more information on the collection reuse and recyclin...

Страница 40: ...ust accept any interference received including interference that may cause undesired operation Changes or modifications made to this equipment not expressly approved by Cognex may void the FCC authori...

Страница 41: ...latory Model 1ABB Regulatory Model 1AAJ Regulatory Model R00043 Regulatory Model 1AAG Regulatory Model R00046 X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 SJ T 11...

Страница 42: ...Reader Control Codes Keyboard Language Corded Readers Only 42 Reader Control Codes...

Страница 43: ...static discharge ESD power surges or other irregularities in the power supply l Changes or modifications not expressly approved by the party responsible for regulatory compliance could void the user s...

Страница 44: ...Copyright 2019 Cognex Corporation All Rights Reserved...

Отзывы: