Additional Information
DataMan 475 Verifier Specifications
Weight
945 g
Field of View
80 x 60 mm
Dimensions
185 x 185 x 175 mm
Power
Consumption
l
24 VDC ±10%, 1.5 A maximum (Label Light, 36 W peak power consumption)
Supplied by LPS or NEC class 2 only.
Light Connector
0.4 A
Note
: The Light Connector is disabled while the Label Light accessory is in place.
Case
Temperature
1
0 °C - 57 °C (32 °F - 134.6 °F)
Operating
Temperature
2
0 °C - 40 °C (32 °F - 104 °F)
Storage
Temperature
-20 °C - 80 °C (-4 °F - 176 °F)
Humidity
< 95% non-condensing
Environmental
IP65 with cables and appropriate lens cover attached
Shock (Shipping
and Storage)
Preliminary - IEC 60068-2-27: 18 shocks (3 shocks in each polarity in each (X, Y, Z) axis) 80 Gs (800
m/s
2
at 11 ms, half-sinusoidal) with cables or cable plugs and appropriate lens cover attached.
Vibration
(Shipping and
Storage)
Preliminary - IEC 60068-2-6: vibration test in each of the three main axis for 2 hours @ 10 Gs (10 to
500 Hz at 100 m/s
2
/ 15 mm) with cables or cable plugs and appropriate lens cover attached.
Supported
Symbologies
1D codes
: Codabar, Code 39, Code 128, and Code 93, Interleaved 2 of 5, UPC/EAN/JAN
2D codes
: Data Matrix (ECC 200), QR Code, microQR Code
Discrete I/O
operating limits
HS Output 0,1,2,3
I
MAX
50 mA
R
MIN
@ 12 VDC
200 Ω
Input 0 (Trigger)
V
IH
±15 — ± 28 V
Input 1,2,3
V
IL
0 — ± 5 V
I
TYP
@ 12 VDC
2.0 mA
@ 24 VDC
4.2 mA
Ethernet Speed
10/100/1000
DataMan 475 Series Verifier Imager Specifications
Specification
DataMan 475 Imager
Image Sensor
2/3 inch CMOS, global shutter
Image Sensor Properties
8.8 mm x 6.6 mm (H x V); 3.45 µm square pixels
1
Additional cooling measures may be required to keep the case temperature from exceeding 50 °C. Examples of such measures include: extra
heat sinking and/or air movement.
2
In situations where the operating temperature exceeds 40 °C, an external heat sink is required.
13
Setting Up Your DataMan 475 Verifier