Model 1460 I/O Expansion Module Installation and Reference
33
Figure B-3: Discrete Output dialog, default configuration (In-Sight PC Host)
5.
Open the drop-down list to the left of the OK button and select I/O Expansion Module. The
Discrete Output dialog will automatically reconfigure to correspond to the I/O Expansion Mod-
ule, as shown in Figure B-4.
6.
Configure the Line Name, Type and Details as required (refer to Appendix A).
NOTE
When an existing .JOB file containing a WriteDiscrete function is loaded on an In-Sight
sensor to which the I/O Expansion Module has just been added, the Start Bit and Number
of Bits parameters in WriteDiscrete must be changed to reflect the new configuration of the
I/O lines. For example, the physical output lines 0 and 1 become lines 8 and 9 (HSOUT 0
and HSOUT 1) when the I/O Expansion Module is enabled.