30
A.2.2 Line Type
One of seven available Line Types is selected from the drop-down menu list. The available
types are described in Table A-5.
The available input types for each discrete input line on the various In-Sight device models
are summarized in Table A-6.
A.2.3 Signal Type
Select a signal type for the selected input line, which controls the sensitivity of the input line
to edge transitions.
•
Rising Edge: Changes the state of the input line on the leading edge of a pulse.
•
Falling Edge: Changes the state of the input line on the falling edge of a pulse.
Table A-5: Discrete Input Dialog Type Parameter
TYPE
DESCRIPTION
User Data
General purpose input line; used to drive events in the spreadsheet or to set a value in the
spreadsheet via the ReadDiscrete function.
Event Trigger
Triggers an event. To update the spreadsheet, the spreadsheet must contain an Event struc-
ture with its Trigger parameter set to this discrete input Line number.
Job ID Number Provides one bit of a Job ID Number, which is loaded when the State of a different input line
with a Type of Job Load Switch is ON.
NOTE: This functionality is provided for backwards compatibility, but it is strongly recom-
mended to use the direct Camera trigger input line.
Online/Offline
Forces the In-Sight device Offline or Online. 0 = Offline, and 1 = Online.
Acquisition
Trigger
Triggers the In-Sight camera to acquire an image. Requires the AcquireImage function’s Trig-
ger parameter to be set to External, and that a signal line is physically connected to the trigger
input of the In-Sight camera.
Job Load
Switch
ON reads all of the Job ID Number lines and loads the specified job.
NOTE
In order to use the Job ID Number function, the job to be loaded must be saved with a
numerical prefix of 0 to 19. For example, “8sample.job”.
Table A-6: Discrete Input Dialog Signal Parameters
MODEL
INPUT LINE
VALID INPUT TYPES
In-Sight 3400
In-Sight 5000 Series
Expansion Module Lines 0
through 7
User Data
Event Trigger
Job ID Number
Online/Offline
1
Acquisition Trigger
1
Job Load Switch
1
1. Indicates that this input type may not be used on more than one input line simultaneously
Содержание 800-5815-1
Страница 1: ......
Страница 2: ......
Страница 6: ...iv ...
Страница 10: ...List of Figures viii ...
Страница 12: ...List of Tables x ...
Страница 16: ...Introduction 4 ...
Страница 48: ...36 ...
Страница 50: ...38 C 1 1 1460 I O Expansion Module Output to PLC Input ...
Страница 52: ...40 C 1 3 1460 I O Expansion Module Output to Pilot Light Input ...
Страница 54: ...42 C 1 5 1460 I O Expansion Module Input to PLC Output ...
Страница 56: ......
Страница 57: ... Q 6LJKW 0RGHO 2 SDQVLRQ 0RGXOH QVWDOODWLRQ DQG 5HIHUHQFH www cognex com 597 0029 02 ...