![COFFEtek VITRO S3 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/coffetek/vitro-s3/vitro-s3_technical-manual_2634525007.webp)
COFFEtek
LTD
7
28/02/2017
Revision 1
VITRO S3
SERVICES REQUIRED
Electrical Supply
5.
(a)
Single Heater Operation
Supply voltage :
230V~, 50Hz, single phase, fused supply
Current rating :
10A/16A
(b)
The fused electrical supply should terminate at an appropriate isolator located within
1m of the beverage machine.
Water Supply
6.
(a)
15mm dia. Water mains supply, terminating at a convenient stop tap located within
1m of the beverage machine.
(b)
Water pressure : 0.1 MPa minimum, 0.8 MPa maximum
(c)
A 15mm double backcheck valve, with inspection port, should be fitted prior to the
flexible hose. The mains Water Supply should be fitted with a suitable water blocker.