COFFE
tek
LTD
17
22/02/08
Issue 1
NEVA 4
ENGINEERS PROGRAM
A
CCESSING THE
E
NGINEER
’
S
P
ROGRAM
14.
The Operator’s Program must be accessed before the Engineer’s Program can be
accessed, the operation is as follows:
(1) Press PROG to access the Operator’s Program, the display will show:
PRESS DRINK TO DISPLAY COUNTER
(2) Press PROG again , the display will show:
TOTAL VENDS
(3) Now, press the bottom left hand selection button on the front of the door.
The display will now show:
SELECT DRINK TO MODIFY
(4) The machine is now in engineer’s mode.
Program Options
15.
Thirteen program options are available as follows:
SELECT DRINK TO MODIFY
SELECT DRINK TO TEST
OUTPUT TEST
CHANGE PRICE OF, OR INHIBIT DRINKS
SET INGREDIENT THROW RATE
TANK STATUS
INITIALISE
CHANGE SETTINGS
PRESS DRINK FOR FIXED COUNTERS
EDIT BIN NAMES
SAVE TO HIGH MEMORY BANK
SET FACTORY DEFAULTS
LEAVE ENGINEERS PROGRAM
16.
Repeated pressing of PROG key causes the program to scroll through the options in the
above sequence. Therefore a specific option is accessed by pressing PROG key until
that option is displayed. To access any program press ENTER.
Содержание NEVA 4
Страница 1: ...NEVA 4 BEVERAGE MACHINE TECHNICAL MANUAL ...
Страница 3: ...COFFEtek LTD 3 22 02 08 Issue 1 NEVA 4 This page is intentionally blank ...
Страница 5: ...COFFEtek LTD 5 22 02 08 Issue 1 NEVA 4 This page is intentionally blank ...
Страница 12: ...COFFEtek LTD NEVA 4 Issue 1 22 02 08 12 ...
Страница 13: ......
Страница 25: ...COFFEtek LTD 25 22 02 08 Issue 1 NEVA 4 This page is intentionally blank ...
Страница 36: ...COFFEtek LTD NEVA 4 Issue 1 22 02 08 36 Section 4 Exploded Parts Diagram ...
Страница 37: ...COFFEtek LTD NEVA 4 Issue 1 22 02 08 38 ...
Страница 38: ...COFFEtek LTD 39 22 02 08 Issue 1 NEVA 4 ...
Страница 39: ...COFFEtek LTD NEVA 4 Issue 1 22 02 08 40 ...
Страница 40: ...COFFEtek LTD 41 22 02 08 Issue 1 NEVA 4 ...