12. Error message - SERVICE
TOWER
Error message: Display shows: E1, E2, E3, E4.
LEVEL CONTROL
TEMPERATURE CONTROL
Display shows:
E1
=
Level sensors short electrod is
Clean level sensor.
earthed, (GND)
Change level sensor.
but not level sensors long electrod.
Cables wrongly coupled.
Display shows:
E4
=
Filling time too long.
Restart machine.
Low pressure on water.
Water tap not open.
Display shows:
E2
=
Temp. sensor out of range
5
°C
- 105
°C.
Temp. sensor failure.
Change temp. sensor.
Cable is loose.
Connect cable.
Display shows:
E3
=
Heating time too long.
Restart machine.
Solid state defect.
Change solid state.
Element defect.
Change heating element.
High limit control defect.
IMPORTANT!
All maintenance and installations must be done of an
authorized technician.
Содержание TOWER
Страница 20: ...20 40 41 42 50 49 48 43 44 45 46 47 51 52 14 Sprängskiss Serveringsstation TOWER 53 ...
Страница 38: ...14 Exploded View serving station TOWER 38 40 41 42 50 49 48 43 44 45 46 47 51 52 53 ...
Страница 39: ...39 15 Elschema Electrical diagram 3 x 400VAC ground zero TOWER ...
Страница 40: ...40 15 Elschema Electrical diagram 3 x 400VAC ground TOWER ...
Страница 41: ...41 15 Elschema Electrical diagram 3 x 230V ground TOWER ...
Страница 42: ...42 16 Måttskiss Dimension sketch Tower station TOWER ...
Страница 43: ...43 16 Måttskiss Dimension sketch serving station TOWER ...
Страница 44: ...44 17 Väggmontering bryggstation Wall mounting brew station TOWER ...