background image

par

Lite

LED

numero di serie/serial number

data di acquisto/date of purchase

fornitore/retailer

indirizzo/address

cap/città/suburb

provincia/capital city

stato/state

tel./fax/

Prendete nota, nello spazio apposito, dei dati relativi al modello e al rivenditore del vostro 

Par Lite LED

: que-

sti dati ci permetteranno di assistervi con la massima rapidità e precisione.

Please note in the space provided above the relative service information of the model and the retailer from

whom you purchased your 

Par Lite LED

: this information will assist us in providing spare parts, repairs or in

answering any technical enquiries with the utmost speed and accuracy.

ATTENZIONE

la sicurezza dell’apparecchio è garantita solo con l’uso appropriato delle presenti istruzioni, per-

tanto è necessario conservarle.

WARNING

: t

he security of the fixture is granted only if these instructions are strictly followed; therefore it is

absolutely necessary to keep this manual.

Users Manual Version 1.0

edition September 2014

Содержание Par Lite Led

Страница 1: ...manuale di istruzioni instructions manual Version 1 0 par lite LED RGBA...

Страница 2: ......

Страница 3: ...d above the relative service information of the model and the retailer from whom you purchased your Par Lite LED this information will assist us in providing spare parts repairs or in answering any te...

Страница 4: ...he projector 9 4 5 Adjusting the beam angle 9 5 Powering up Pag 11 5 1 Operating voltage and frequency 11 5 2 Mains connection 11 6 DMX signal functions Pag 12 6 1 Connecting DMX signal 12 6 2 Powerin...

Страница 5: ...4 A good earth connection is essential for proper functioning of the projector Never operate the unit without proper earth connection 5 The mains cable should not come into contact with other cabling...

Страница 6: ...IP Rating IP20 standard version IP65 IP version 3 2 Dimensions 3 3 Projector components The principal components of the Par Lite LED are shown in the diagram below Descriptions of the components 1 IP2...

Страница 7: ...hting truss or similar we recommend the use of appropriate clamps B affixed to the yoke in the holes A provided as shown in the following diagram Never install the fixture in a position in an accessib...

Страница 8: ...hain both suitably rated for the purpose 4 3 Adjusting beam direction The Par Lite LED can be tilted to adjust the beam output To perform this adjustment follow the instructions set out below 1 Loosen...

Страница 9: ...lenses for a larger projection angle a flood reflector and several filters that can be fitted either internally or externally to the unit The standard optical group fitted on Par Lite Led is composed...

Страница 10: ...lable for the Par Lite Led To shape the beam you can use an external barndoor code CO9164 Optical group Beam angle Narrow Lenses standard 12 Narrow Lenses Light Frost Filter 17 Narrow Lenses Frost Fil...

Страница 11: ...of a suitable rating 230 240V 0 2 amps constant current 208V 0 25 amps constant current 100 115V 0 5 amps constant current Locate the mains cable which exits the base of the unit and connect as shown...

Страница 12: ...power on to the unit The DISPLAY will come on Turning on power with DMX signal connected The Display will flash to indicate that DMX 512 is not being correctly received If the Display not flash the DM...

Страница 13: ...plete control IMPORTANT NOTE the following points are valid for all the instructions which follow 1 The DMX address may be altered without the need to turn the Par Lite LED off The following are examp...

Страница 14: ...p o t s proportional sequenced pulse effecr fast closing slow opening variable speed pulsing from slow to fast e b o r t s p o t s proportional random strobe effect with variable speed from slow to f...

Страница 15: ...his manner ATTENTION It is onlypossible to select one program at a time 7 Auto function 15 English out Ad altriPar Lite Led SLAVE Connect to other Par Lite Led SLAVE out in FUNC menu AOO1 MODE o MEAS...

Страница 16: ...de enter AOO1 enter MA master function Master unit PRG 1 Example program 1 enter PROGprogram To select the number of program to run SPEE speed Memories running time sec WAIT waiting time Waiting time...

Страница 17: ...r channel enter o es enter 0020 0 1 2 7 DMX DMX function DMX function mode o 4CH enter FREfrequency Frequency of the LED o 600 enter D MAXcalibration Disables the adjusting of LEDs setting them at max...

Страница 18: ...TEMPtemperature Misure the led housing internal temperature in C enter 10 DMX value reading 255 DMX value reading DMINvalore DMX su ogni canale Reading of DMX value 0 255 received by each of the 8 ch...

Страница 19: ...0001 enter o 0012 o MIN B led blue alignment Alignment led blue minimum intensity enter 0001 enter o 0015 o MAX Rled red alignment Alignment led red maximum intensity enter 0250 enter o 0255 o MAX Gl...

Страница 20: ...rotection fuse in the re Fuse A 4A T 250V ATTENTION Always remove mains power prior to opening up the fixture 10 Maintenance 9 Thermal protection MESSAGE CODE DESCRIPTION DTER DATA Error The initial s...

Страница 21: ...diagram below indicates some possible problems and solutions if they should occur Problem Possible solution Par Lite LED won t turn on Mains power is not available to the Par Lite LED Check that the D...

Страница 22: ...a 2 46042 Castel Goffredo Mantova Italy ph 39 0376 1514412 fax 39 0376 1514380 info coemar com Coemar si riserva il diritto di apportare modifiche senza preavviso Coemar reserves the right to effect m...

Отзывы: