background image

12

English 

Each 

iSpot 575

utilises 

20

or 

21 

channels of DMX 512 signal for complete control. The number of channels varies

depending on the mode (

Mode

) selected; 

Mod1

(20 channels), 

Mod2

(21 channels). The additional channel offers further

functions (for more details see paragraph 

12. DMX 512 signal functions

)

DMX coding

To ensure that each projector accesses the correct signal, it is necessary to correctly address each fixture. Any number
between 1 and 493 can be generated via the multifunction panel of the 

iSpot 575

.

This procedure must be carried out on every 

iSpot 575

being used. 

When powered up initially, each projector will show 

A001

which indicates 

DMX address 1

; a projector thus addressed

will respond to commands on channel 

1

to 

20

from 

DMX 512 controller

. A second unit should be addresses as 

21

, a

third as 

41

and so on until the final 

iSpot 575

has been addressed.

Altering DMX addresses

1) Press the 

+

or 

-

button until the display shows the 

DMX

required, the characters in the display panel will flash to indicate

that the selection is not stored in memory.

2) Press the 

enter

button to confirm your selection; the display will stop flashing and the projector will now respond to the

new DMX address.

3) To better understand the function of each channel, we refer you to section 12 “Control channel functions from a 

DMX

512

controller”.

Important Note

: Keeping the 

+

or 

-

button pressed will cause the display to alter at increased speed, allowing a faster

selection to be effected.

By pressing the 

button, you may inadvertently select a DMX address which is not being communicated to the fixture by

the controller, for example 500. If this is the case, the display will slow the data reception, (since it does not exist), and you
will note that it is slow to respond to your commands (for example altering an address or requesting or confirming a reset).
You may solve this problem by either sending data to this address, or by altering the incorrect DMX setting of the 

iSpot

575

in question.

function
display

DMX

menu enter

+

Set dmx 512 address

A O O 1

enter

A001 

to 

A493

10. DMX addressing

www.carlosmendoza.com.mx

Содержание iSpot 575

Страница 1: ...1st edition february 2002 instructions manual 575...

Страница 2: ...g up the iSpot 575 without articulated movement 14 11 2 Counter reset 14 11 3 test 14 12 DMX 512 signal functions 15 13 Aligning the lamp in the optical system 17 14 Opening up the projector housing 1...

Страница 3: ...at no part of the equipment has suffered damage in transit In case of damage to the equipment contact your carrier immediately by telephone or fax following this with formal notification in writing pa...

Страница 4: ...n areas of extreme humidity A steady supply of circulating air is essential Protection against ultraviolet radiation 1 Never turn on the lamp if any of the lenses filters or the carbon fibre housing i...

Страница 5: ...the lamp exists if operated over its recommended life of 1000 2000 hours We recommend therefore that the lamp be replaced within the manufacturer s specified lamp life installing the lamp 1 Using a P...

Страница 6: ...er make sure therefore that the cor rect pin is lined up into its respective pin socket DO NOT USE UNDUE FORCE In case of difficulty re read the instructions and repeat the procedure 5 Replace the lam...

Страница 7: ...tage of the projector at any time by using the selector located on the base of the pro jector The selector allows you to choose from 2 preset voltages indicated on the sticker located adjacent to the...

Страница 8: ...t of the unit You may attach the safety chain to iSpot 575 via the holes in the fixture s base B protection against liquids The projector contains electric and electronic components that must not come...

Страница 9: ...as described in section 5 of this manual Prior to connecting the unit to your mains supply ensure that the model in your possession correctly matches the mains supply available to you For connection...

Страница 10: ...standard pin 1 screening 0 volt pin 2 data pin 3 data If using a controller which output signal via an XLR 5 5 pin socket do not use pins 4 and 5 leaving them unconnected Ensure that all data conducto...

Страница 11: ...d external motors This will last some few seconds after which it will be subject to the external signal from the controller DMX led The DMX led will be static on to indicate that DMX 512 signal is bei...

Страница 12: ...the characters in the display panel will flash to indicate that the selection is not stored in memory 2 Press the enter button to confirm your selection the display will stop flashing and the project...

Страница 13: ...e display visualization T E S T motors test Device operation test without using DMX signal RESE reset Reset function DEMO demo program To demonstrate the fixture s operativity RATE DMX speed DMX signa...

Страница 14: ...n 4 Press the or button until the display shows LIFE for lamp life 5 Press the enter button to confirm your selection the display will show 0000 confirming that the counter has been reset 11 3 test Th...

Страница 15: ...55 7 iris step open 0 9 proportional from large to small 10 124 step irissmall 125 129 proportional iris pulse with increasing pulse speed 130 189 step open 190 192 proportional iris pulse with increa...

Страница 16: ...w 128 190 step No rotation 191 192 proportional Backwards rainbow effect from slow to fast 193 255 1 8 color wheel 2 step Open white 0 7 step or proportional depending on ch 19 color 1 8 27 step or pr...

Страница 17: ...d B to bring the hot spot to the centre of the beam Use the third adjuster C to flatten the beam to maxi mum uniformity vertical adjustment Screw B acts on a lever and spring assembly to position the...

Страница 18: ...Loosen the screws which affix the upper and lower covers 1 Once unscrewed simply lift the covers to access the internal components of the fixture Attention Remove mains power prior to accessing the in...

Страница 19: ...wheel 1 closest to the lamp external 32 9 mm image area 26 mm thickness 0 2 3 5 mm gobo wheel 2 external 32 9 mm undefined image area 30 mm outlined image area 28 mm thickness 0 2 3 5 mm Gobos should...

Страница 20: ...te the autotransformer in the base of the unit 3 Select a voltage from amongst 100 115 208 230 and 240V by removing cable n 6 and moving it to the required volt age To determine which is the correct t...

Страница 21: ...f the base 2 Select from either 50 or 60Hz by moving cable n 16 to the required position To ensure you have selected the correct tap refer to the sticker located on the power supply Cable number 17 sh...

Страница 22: ...nds in every subsequent minute This is designed to protect the ballast and lamp ignitor from prolonged usage in less than ideal conditions NOTE it is important to replace a lamp that is at the end of...

Страница 23: ...a common vacuum cleaner or an air compressor periodic maintenance lamp The lamp should be replaced if there is any observable damage or deformation due to heat This will avoid the danger of the lamp e...

Страница 24: ...nt TLAL tilt alignment Tilt movement alignment SH R shutter alignment Shutter s right half alignment SH L shutter alignment Shutter s left half alignment C1AL color wheels alignment Color wheel 1 alig...

Отзывы: