4.4. Error messages

ESYS

Operating system error, often caused by an incomplete data transfer from DR-2. Retry the data transfer to correct the problem.  

EFIX

Memory error, often caused by an incomplete data transfer from DR-2.  Retry the data transfer to correct the problem.  

EDMX

Communication error between the fixture processor and DMX.  If caused by a recent incomplete data transfer from DR2 retry
the transfer, upgrade the DMX software or replace the CE107 Main PCB.  

DMX ERR

DMX communication error.  Verify that DMX data is present.  Possible causes include the wiring between the DMX input and
CE107 Main PCB or defective CE107 PCB.  

(MOTOR NUMBER) NO LINK

Communication error between the CE107 Main PCB and the indicated motor.  Possible causes include the wiring between
CE107 PCB and the Motor PCB or the Motor PCB may have failed. 

FAN2 NO LINK

Communication error between the CE107 Main PCB and the fan driver board on bus 2.  Possible causes include the wiring
between CE107 PCB and the Fan PCB or the Fan PCB may be defective.  

FAN4 NO LINK

Communication error between the CE107 Main PCB and the fan driver board on bus 4.  Possible causes include the wiring
between CE107 PCB and the Fan PCB or the Fan PCB may be defective.

BUS2 FAIL

The number of motor cards found on bus 2 does not match the software version installed.  

BUS4 FAIL

The number of motor cards found on bus 4 does not match the software version installed. 

(MOTOR NUMBER) RST ERR

The indicated motor has failed to reset in the allotted time.  Check that the motor is free to move and that the wiring from the
motor board to the motor is intact.   Use the sensor test mode to verify that the sensor is detecting the motor when the sensor
passes the magnet or the flag interrupts the opto sensor.  

(MOTOR NUMBER) INI ERR

The indicated motor has not completed its initialization routine in the allotted time.  

Check that the motor is free to move and that the wiring from the motor board to the motor is intact.  Use the sensor test mode
to verify that the sensor is detecting the motor when the sensor passes the magnet or the flag interrupts the opto sensor.

(MOTOR NUMBER) OPTO ERR

The opto sensor associated with this motor did not detect the flag.  Check that the motor is free to move and that the wiring

from the motor board to the motor is intact.  Use the sensor test mode to verify that the sensor is detecting the motor when the
flag passes through the opto sensor.  Check that the sensor is clean.  

(MOTOR NUMBER)  ENC ERR

The position encoder associated with the motor has detected an error.  This may be due to the opto sensor or encoder wheel

failing to properly encode the motor motion.  Check the sensor, encoder and wiring.

(FAN NUMBER) ERR

The indicated fan has produced an error.  Fan velocity is returned to the microprocessor through a third wire on the fan motor.

Check that the fan is free to move, that the wiring from the fan to the fan board is intact.  Check that the air filters are clean and
airflow is unrestricted.  

DR2L

Flex is connected to 

dr2

, The 

+

/

-

/

menu

/

enter

/

more

buttons are disabled

UPGR 

indicates upgrade in process.

Flex is connected to 

dr2

, The 

+/-/menu/enter/more

buttons are disabled, software upgrade is active.

4.5. Special Features

Turning on the iSPOT FLEX without movement 

This function may be useful should you need to power up the fixture inside its roadcase or for any other reason where you

may wish to power up the unit without it moving pan and tilt motors.  All motors will be energized and reset as normal except for
pan and tilt motors.  

1) Power up the projector while pressing the 

<more> 

button.

The projector will switch on without the usual reset functions.
You may at this point alter a DMX address, or any other menu-based parameter without pan and tilt movement.
This function is particullarlty useful to test the sensors, load the new software to PCBs and to re-address the PCBs network.

4) To resume normal fixture functioning, you must turn the projector off and on again via the 

power 

button or reset the light using

the display 

RST

command

11

Содержание iProfile Flex

Страница 1: ...2st edition july 2004 provisional instruction manual...

Страница 2: ......

Страница 3: ...onstructs Map 8 4 3 Menu Functionality 8 4 4 Error messages 11 4 5 Special Features 11 5 DMX Chart 12 6 Installation 12 6 1 Power 12 6 2 Mounting 12 6 2 1 Orientation 12 6 2 2 Fitting Clamps 13 6 2 3...

Страница 4: ...ammable materials at least 2 m 6 ft from the fixture Keep air intakes and exhaust open and free of debris Replace fuses only with specified type and rating Do not cover the fixture or lens with any ma...

Страница 5: ...er 9124 2 3 Fuse Specification Power supply 5x20 mm T 6 3 A 250V Main 2 fuses 6 3x32 mm T 16 A 250V 2 4 Lamp Specification Philips MSR 2000 SA coemar part number 105258 Rated Lamp Life 750 hours at 20...

Страница 6: ...ned line dwgs as shown angular rotation values 595mm 23 43 290mm 11 42 370mm 14 57 930mm 36 61 635mm 25 145mm 5 70 315mm 12 40 320mm 12 60 620mm 24 40 545mm 21 46 35mm 1 38 iPROFILE Flex m a d e i n i...

Страница 7: ...irements Voltage mains supply 190 245V 50 60 Hz Current 5 5A 240V for 1200W output to 11 3 A 240V for 2000W output Fuse ratings power supply 5x20 mm T 6 3 A 250V mains fuses 2 6 3x32 mm T 16 A 250V Da...

Страница 8: ...measure and display operating parameters of the fixture Enter the MEAS feature from the default address menu A001by pressing menu then To enter the individual menus from MEAS press enter followed by...

Страница 9: ...the tilt sensor Rotate the fixture manually and the display will indicate either OK if functioning properly or BAD if the sensor is defec tive FOCU test focus lens sensor ZOOM test zoom lens sensor CO...

Страница 10: ...leted adjustment of the offset s select END to accept changes and exit If you want to escape from the function without changing any value press menu to exit without save AMS Menu The AMS menu provides...

Страница 11: ...g from the motor board to the motor is intact Use the sensor test mode to verify that the sensor is detecting the motor when the sensor passes the magnet or the flag interrupts the opto sensor MOTORNU...

Страница 12: ...ground Floating or noisy grounds may affect fixture performance cause erratic behavior or damage and present a shock hazard DO NOT power the fixture through a dimmer system 6 2 Mounting 6 2 1 Orientat...

Страница 13: ...ing safety cables fitted 6 2 4 Secure power and data cabling Data power and safety cables should be dressed such that no wires are adjacent to the fixtures moving parts or might become entangled in th...

Страница 14: ...ler Following proper data distribution practice will insure optimum performance of your new Flex fixtures for years to come Cable specification Cable used for data should comply with RS 485 standard 2...

Страница 15: ...ou trouble free performance of your new Flex products Figure W8 Fixture console bidos Bidirectional Opto Splitter dr2 interconnect DMX data present Your Flex fixture allows you to confirm the presence...

Страница 16: ...he switching power supply To replace the switching supply fuse remove the base covers as in Figure 11A followed by removing the 4 supply retaining screws on the bottom of the fixture as in Figure 11B...

Страница 17: ...oving Switching PS screws Figure W12D Removing the Switching PS Fuse To access the PCB s located in the yoke remove the four screws retaining the covers and pull the covers upward and out You now have...

Страница 18: ...ould be installed with the texured surface AWAY from the glass Figure W16 Determining Coated Side of Dichroic Changing Fixed Colors Remove the top cover of the fixture and locate the Gobo Gobo Effects...

Страница 19: ...t it is visible from the color wheel side of the module Hold the gobo gear on the underside of the plate by hand while you unscrew the retaining ring using the gobo tool provided with a counter clockw...

Страница 20: ...ce heating of the optical components inside your Flex Always handle dichroic filters by the edge or using a soft cloth Oil from your skin on the dichroic surface will result in heating and failure of...

Отзывы: