Infinity ACL M
utilizes a Philips MSR GOLD 700/2 Mini Fast Fit with PGJX28 base lamp.at maximum power of 700 W or a Philips
MSR GOLD 575/2 Mini Fast Fit with adequate ballast setting.(menù MAIN FUNCTIONS/BALLAST SETTINGS). These lamps are
available as a spare part at your
Coemar
’s distributor or service centr
e.
Lamp
Philips MSR Gold 700/2 Mini Fast Fit
Philips MSR Gold 575/2 Mini Fast Fit
Coemar code
105830
105831
Power range
700 W (full power), 400W (low power)
575 W (full power), 400 W (low power)
Lighting flow
50000 lm
35600 lm
Colour temperature
7200°K
7400 °K
Base
PGJX28
Life
750 h.
WARNING !
Balast setting and lamp replacement must be done by qualified personnel.
Disconnect the unit from main power prior to attempting lamp’s installation or replacement.
The fixture internal temperature can reach 250° C after 5 minutes, and reach a peak of 350 °C; make sure that the lamp is cold
before trying to remove it. In any case the fixture can be opened only 10 minutes after turning off the lamp.
The lamp is of the mercury vapour type with discharge ignition. This type of lamp operates at high internal pressure, and a slight
risk of explosion exists if the lamp is operated beyond its recommended life. Therefore, we recommend to replace the lamp within
the specified lamp life. Always handle the lamp with care avoiding to touch it with bare hands.
9.1 Lamp installation
1.
Use a suitable tool to loosen the 2 fixing screws A of the lamp holder cover at the rear of the projector body.
2.
Remove the lamp holder cover “B”.
3.
Insert the lamp into the holder and gently rotate it clockwise until it blocks.
4.
Una volta in sede, ruotate la lampada in senso orario fino a bloccarla. The lamp used is made of quartz glass and must be
handled with care; always adhere to the instructions provided in the lamp packaging. Never touch the glass directly, use the
polythene wrapping provided in the lamp packaging. DO NOT USE UNDUE FORCE ON THE GLASS.
5.
Insert the lamp holder cover in its original position and screw the 2 screws “A” back in.
WARNING !
-
Never use undue force if the procedure becomes difficult.
-
Never put pressure on the glass of the lamp.
Never touch the glass of the lamp with bare hands.
A
B