Coemar F026G000A Скачать руководство пользователя страница 27

27

11.

 Maintenance

11.2 

Periodic cleaning

Lenses

Even  a fine  layer  of  dust  can  reduce the  luminous  output  and  alter the  compactness  of the 
beam. Regularly clean all filters and lenses using a soft cotton cloth, dampened with a specialist 

lens cleaning solution.

Cleaning of the unit

Use a soft brush or a common vacuum cleaner or a source of compressed air for removing dust. 
For the cleaning of the housing use a soft cloth and a non-aggressive cleaner. Check that the 
internal fans and heat exchanger must be perfectly clean.

11.3 

Periodic controls

Mechanical components

Check the correct working of the mechanical parts and, if needed, replace them. Make sure the 
projector is not mechanically damaged. If necessary, replace the worn parts.

Electrical components

Check all electrical connections, in particular for correct grounding and correct attachment of 
all extractable connectors. Press the connectors if necessary and reposition as before.

11.1

  

Firmware update

The firmware of 

Softlite Led VariWhite

 can be updated through the RDM protocol (ANSI E1.20). 

Contact 

Coemar

 assistance to receive the software and the device updater.

11.4 

Fuses

Softlite Led VariWhite 

 

has an automatic fuse that in most cases does not need to be re-

placed.

Содержание F026G000A

Страница 1: ...SoftLite Led VariWhite Version 1 0 Instruction manual...

Страница 2: ...he model and the retailer from whom you purchased your SoftLite Led VariWhite this information will assist us in providing spare parts repairs or in answering any technical enquiries with the utmost s...

Страница 3: ...ounting the accessories Pag 11 5 Powering up Pag 12 5 1 Operating voltage and frequency Pag 12 5 2 Connection to mains power Pag 12 5 3 Supply cable characteristics Pag 12 6 Control signal connections...

Страница 4: ...4 11 Maintenance Pag 27 11 1 Firmware update Pag 27 11 2 Periodic cleaning Pag 27 11 3 Periodic controls Pag 27 11 4 Fuses Pag 27 12 F A Q and answers Pag 28...

Страница 5: ...orm them you will formally notify them in writing through registered letter Packing list Make sure the packaging contains 1 SoftLite Led VariWhite 1 Instruction manual 1 Main power plugs 2 General inf...

Страница 6: ...ncipal fixing point 3 The external surfaces of the unit at various points may reach 60 C Nev er handle the unit until at least 10 minutes have elapsed since the LED was turned off 4 Never install the...

Страница 7: ...control of white color temperature from 2700 K to 6500 K CRI Color Rendering Index 90 Weight 9 6kg 21 1lbs Minimum ambient temperature 20 C 4 F Maximum ambient temperature 35 C 95 F IP rating IP20 3...

Страница 8: ...ts description A Locking knobs B Yoke C Cooling slots D Front panel E Back panel F Accessories hooking 3 4 Back panel description A A B C D E F Display and keyboard DMX In and Out 5 poles connector Po...

Страница 9: ...g bolts clamps etc are rated to support the weight of the fixture 4 2 Safety chain When hanging SoftLite Led VariWhite it is recommended to use a safety chain as required by current legislation The sa...

Страница 10: ...10 4 3 Adjusting unit s tilt In order to adjust the tilt of the unit simply loose the side handle adjust the tilt and lock the yoke by tightening the handle again...

Страница 11: ...11 4 4 Mounting the accessories To mount an accessory you have to loose the small knob A insert the accessory that you need and close the knob A A...

Страница 12: ...180 C Coemar cod CV5311 Connection to mains power SoftLite LED VariWhite is equipped with two power connectors one as input and one as out put which can be used to feed up to 10 at 230 VAC or 5 90 VAC...

Страница 13: ...d VariWhite should not be powered through a dimmer as this may damage the internal switching power supply Prior to connecting the device to mains power ensure that the mains characteristics are within...

Страница 14: ...ing to the International standards for the transmission of DMX 512 data The connection must be serial using connectors XLR5 male and female located on the back of SoftLite Led VariWhite labeled DMX512...

Страница 15: ...s complete operation and is controlled by a DMX 512 signal DMX addressing When powered up initially each projector will show A001 which indicates DMX address 001 for example when set at 6 channels a p...

Страница 16: ...23 25 3600 K 65 70 25 27 3700 K 71 76 28 30 3800 K 77 82 30 32 3900 K 83 88 33 35 4000 K 89 94 35 37 4100 K 95 100 37 39 4200 K 101 106 40 42 4300 K 107 112 42 44 4400 K 113 118 44 46 4500 K 119 124 4...

Страница 17: ...fast and synchronized colors 162 207 64 81 step stop strobe 208 209 82 82 proportional random strobe effect with variable speed from slow to fast and non synchonized colors 210 255 82 100 6 special fu...

Страница 18: ...28 30 3800 K 77 82 30 32 3900 K 83 88 33 35 4000 K 89 94 35 37 4100 K 95 100 37 39 4200 K 101 106 40 42 4300 K 107 112 42 44 4400 K 113 118 44 46 4500 K 119 124 47 49 4600 K 125 130 49 51 4700 K 131...

Страница 19: ...of the projector so that it will respond differently to the controller therefore carefully read about the functions described here before carrying out any possible selection 9 2 Rapid count Through t...

Страница 20: ...u ally the white temperature Strobe manually sets the strobe DMX channel Store stores the modifications that will be set at the next times the fixture will be turned on Fan speed Balance the fan speed...

Страница 21: ...be come active only when the DMX address selection is displayed A001 The effect of AUTO and HOLD trigger after 10 sec onds of keyboard inactivity To turn on the display it is enough to push a button...

Страница 22: ...e power supply voltage DMX input Shows the value of the DMX channels received by the fixture on every channel that the fixture occupies on the line Rate Shows the refresh rate of the DMX signal sent b...

Страница 23: ...of the fixture Unit shows the overall hours of life of the fixture LED life shows the overall LED mod ule life LED life reset shows the overall LED module life currently installed Note this items can...

Страница 24: ...ad the following prior to attempting any changes Warning This menu can only accessed in the DF SE Default Settings menu by pressing at the same time ENTER and MENU buttons This menu shall be accessed...

Страница 25: ...ns off after 10 minutes of fixture inactivity Error code Description nOAL No alarm No Alarm The projector self diagnostic routine didn t find any issue DTER Data Error Data error Initial data loading...

Страница 26: ...ersatile fixture optional accessories for its customization are available under request 10 Accessories and spare parts All the components of Softlite Led VariWhite are available as spare parts from yo...

Страница 27: ...tly clean 11 3 Periodic controls Mechanical components Check the correct working of the mechanical parts and if needed replace them Make sure the projector is not mechanically damaged If necessary rep...

Страница 28: ...controller Softlite Led VariWhite does not answer to DMX signal DMX signal may not reach Softlite Led VariWhite Inspect the cable connection correct poor connections or inefficient repair or replace d...

Страница 29: ...User notes...

Страница 30: ...enter for waste electrical and electronic equipment The treatment and disposal of environmentally friendly helps prevent potential negative environmental and health and promote the reuse and or recycl...

Страница 31: ...ighting s r l Via Carpenedolo 90 46043 Castiglione delle Stiviere Mantova Italia tel 39 0376 1514412 fax 39 0376 1514380 info coemar com Coemar reserves the right to effect modifications without notif...

Отзывы: