background image

ENGLISH

OPERATION

CONSTRUCTION CHARACTERISTICS

TECHNICAL CHARACTERISTICS

HYDRAULIC CONNECTION (Fig.1)

ATTENTION.

ATTENTION.

ELECTRIC CONNECTION (fig. 2)

WARNING.

STARTING.

POSSIBLE PROBLEMS

The OPTIMATIC controller orders the automatic start and stop of
the water pump when opening or closing any tap or valve of the
installation.When the water pump starts, it keeps running while it
exists any tap opened in the system, giving a constant flow an
pressure to the network.

- Inlet male G 1'.

- Outlet male G1'.'
- Special non return valve which avoids surges
- Security system avoiding the possibility for the machine to work

without water

- Pressure gauge
- Tension LED (POWER)
- Security system LED (ALARM)
- Pump-working LED (ON)
- Manual start switch (RESET)
- Integrated socket for motor connection according toCDIN-IEC

884-1.

- Cable with plug DIN 49 441 for connection to the electric supply.

- Tension:                                                  ~220/240 V
- Max. Intensity:                                      16(8)A
- Frequency:                                             50/60 Hz
- Protection:                                             IP44
- Max. temperature of water:               60° C
- Max. Flow:                                             10.000 l/h
- Starting pressure:                                 Type F15: 1,5 bar

Type F22: 2,2 bar
Type R:1,5 bar-2,5 bar

- Max. pressure for use:

10 bar

- Max. Pump power:

230V: 2HP(1500W)

Before proceeding with hydraulic connection it is essential to prime
the pump correctly. The electronic controller should be installed
always in horizontal position with the overmolded arrow pointing
to the top, connecting the inlet opening (male G1

) directly to the

pump and the outlet opening (male G1

) to the network.

Avoid oulet non return valves. The following

accessories are recommended: flexible with disassembling link for
network connection, protecting the set from possible flexion
charges and vibrations. Ball valves which allows the isolation of the
pump from the installation.

The water column between the pump and the

highest point of the installation depends on the starting pressure.
Here below, we give you a list with the height of the column and
the maximum pressure which must supplies the pump.

The adjustment of the starting pressure in type R is made by the
screw placed in the back side of the device (fig.3)

Check the power supply to be ~220/240V. Connect the pump to
OPTIMATIC through the SCHUKO SOCKET. The OPTIMATIC can be
used with a single-phase pump with electrical input under 10 A.

Bad connections may spoil the electronic circuit.

H07RN-F 3G1 type cables (Ø8÷11mm) must be used in order to
ensure IP 44 protection.

1.-Be sure that the pump is primed, then slowly open a tap.
2.- Connect the electronic controller to the electric supply. The

tension LED will lit (POWER).

3.-The pump starts working automatically and within a

period of 20-25 seconds the pressure gauge will reach
approximately the maximum pressure provided by the pump.
During its working the corresponding LED (ON) will be on.

4.-Close the tap indicated on point 1. After 10-12 seconds the

pump will stop. The tension LED (POWER) will be the only one to
remain on.

Any problem after this procedure will be due to a defective pump
priming.

1.-
a) Water leak higher than 1,5 l/min. at some point:

Check the installation, taps, WC, etc.

b) Manual start switch (RESET) is blocked:

Act on it several times,in case the problem persists consult
your dealer.

c) Breakdown on the electronic card: proceed to its substitution.
d) Incorrect electric connection: check  the connections

according to Fig.3.

2.-
a) Not enough water supply, the security system has been

activated and the LED (FAILURE) is on: check the water supply
and restart the pump through the reset switch (RESET).

b) The pump is not hydraulically primed. The safety system against

dry operation has been activated and the LED (FAILURE) is on: fill
with water the inlet, drain the water surplus in the installation
opening a faucet located to he same level of the pump - to
diminish the pressure of the water column over the flow sensor -
and restore the operation mode using the pushbutton RESET.

c) Pump is blocked: LED (FAILURE) is on, the security system is

activate: when we act on the manual start switch (RESET) the
LED (ON) is activated but the pump does not work:
Consult your dealer.

d) Failure in the electronic circuit:

Switch off power supply, wait a few seconds and turn it on again.
If the pump does not start immediately then replace the circuit.

e) Not electrical supply: check the proper electric feeding.The

tension LED (POWER) should be on.

f) Not enough pump pressure:

The security system has been activated and the
corresponding LED (FAILURE) is on. Check that the pump
pressure is the one shown in the hydraulic connection table.

g) Air in the pump aspiration: the pressure gauge will indicate a

pressure lower than the nominal or constant oscillations. The
security system will act by stopping the pump, the LED (FAILURE)
will be on.
Check the sealing of the connections and O-ring of

the

aspiration conduct.

3.-
a) Small leak in some point of the installation:

Verify possible tap or WC tank leaks and repair them.



?

?

?

Pump does not stop:

Pump does not start:

The pump starts and stops repeatedly:

USING HEIGHT             ADJUSTMENT PRESSURE

MIN.PUMP PRESS

10m

1,2bar

1,7bar

15m

1,7bar

2,2bar

20m

2,2bar

2,7bar

Отзывы: