2.0 INSTALLATION
The constructor is not be considered responsible in case of:
•
Improper use fo the unit or use by not trained staff
•
Use in contrast with the directions on work safety
•
Wrong installation
•
Defective power supply
•
Serious lacks in the necessary maintenance
•
Unauthorized modifications and interventions
•
Use of spare parts that are not original or not specific for the unit
•
Toatl or partial inobservance of instructions
•
Unusual events
The lamp must be changed if damaged or deformed by heat.
WARNING: switch off the projector before operating.
Read carefully the lamp builder’s instructions.
2.1 LAMP MOUNTING AND REPLACING
The units mounts high pressure lamp with external traditional striker.
Wait at least 10 minutes af-
ter the projector has been swit-
ched
off
before
operating
again, in order to let it cool
down and avoid the lamp ex-
plosion.
Wait 20 minutes in case
you are operating with the bare
hands in order to avoid burns.
Remove the projector cover by
backing the A screws off. Loosen the lamp’s escutcheons (part.
B
) hand house the lamp in the lampholder (part.
C
).
Put the projector cover back and screw up the
A
screws.
ATTENTION!
A lamp safety cut-off is activated when the cover is not correctly closed.
Remove the elastic band
that’s blocking the motor of scansion group. For the mirror replacement
(C)
, screw the two screws
(B)
and remove
the broken mirror. Install the new spare part (its support is already mounted by the factory) on the motor
A
, carefully
closing, using an hexagonal screwdriver.
WARNING!
The mirror is very delicate, so you must handle it with great care.
2.2 MIRROR MOUNTING OR REPLACEMENT