3. Specifications
3.1. General
Construction
-
Stainless Steel 316 Ti
– other grades available on request.
Safety & EMC
-
shielded to comply with 2006/95/EEC
-
EN61326-1:2006 & EN50270:2006
Ambient temperature
-
-20
o
C to +50
o
C.
Dimensions
-
Ø150mm x 81mm x 150mm
Power
-
24V DC, 20VA
3.2. Visibility Measurement
Measurement path
-
6m
Visibility measuring range (standard)
-
Visibility : 0-15 x 10
-3
m
-1
-
other ranges selectable on setup.
Air temperature
-
PT100 resistance thermometer - range -20°C to +105°C
Averaging time
-
1 to 12 minutes.
Accuracy
-
Visibility - ±0.2 x 10
-3
m
-1
-
Temperature ± 0.2°C
Outputs
-
analogue - 2 x 4-20mA, 200V common mode isolation - fully configurable for visibility and
temperature measurement.
-
max. load 500
-
logic
– 1x volt-free contacts SPCO, 0.5A @ 125V AC,
2A @ 30V DC, 0.5A @ 100V DC
-
RS485 serial interface.