background image

2.5  Front Panel Operation 

 

2.5.1    Output Circuit Over-current Protecting 

A fuse is in every output circuit of

 CODE Tc-182

. The fuses are 10Amp. 

 

2.5.2    Setup DMX-512 Address Code and output Control memory Mode 

The DIP encoder on the front panel of

 CODE Tc-182

 takes on double-duty functions:   

 

Confirming the local inception address number by binary encoding;   

 

Confirming output control memory mode. 

 

2.5.2.1    Confirming DMX-512 Local Inception Address Number 

“Local Inception Address number” is confirmed by 1~9bit switches of DIP encoder. No. 1 bit is LSB, No. 9 bit is 

MSB. In all the address number is 512.    The “Inception Address number” is the channel number code of DMX 

signal which is accepted by the first channel of this set, the second channel accepts DMX signal code of 

“Inception Address number” + 1, the third channel accepts DMX signal code of “Inception Address number” + 2, 

etc.      (If Local Inception Address number is “0”, then the first channel of this set accepts No.1 channel code of 

DMX signal.)    The relation between bit value of DIP encoder and DMX channel code keeps to the formula below:   

 

The sum value of 1~9bit switches of DIP encoder

 ] 

+ 1 = DMX inception address number   

 

DIP switch’s position function: “ON”, obtains its bit value; “OFF”, its bit value is “0”. 

 

Bit value of DIP switches   

 

 

Example 1:    DMX inception address number is “19”       

Setup No.2bit and No.5bit “ON”, the others “OFF”. 

The sum value of 1~9bit of DIP encoder is 2+16. 

Then, DMX inception address number is 19. 

namely:    [ 2 + 16 ] + 1 = 19 

 

 

Example 2:  DMX inception address number is 217 

Setup No.4bit, No.5bit, No.7bit, and No.8bit “ON”,   

the others “OFF”. The sum value of 1~9bit of DIP   

encoder is 8+16+64+128. Then, DMX inception   

address number is 217. 

namely:    [ 8+16+64+128 ] + 1 = 217 

 

DIP bit 

1 2 3 4 5 6 7 8 9 

Value 

1 2 4 8 16 32 

64 

128 

256 

Отзывы: