Code Blue IA500 Series Скачать руководство пользователя страница 23

Code Blue

 

 259 Hedcor Street 

 Holland, MI 49423 USA 

 800.205.7186 

 www.codeblue.com

GU-144-M

page 23 of  24

IA500

Administrator Guide

14  Warranty

Code Blue Corporation provides a limited warranty on this product. Refer to your sales agreement 

to establish the terms. In addition, Code Blue’s standard warranty language, as well as information 

regarding support for this product while under warranty, is available at 

www.codeblue.com/support

.

Notice: Every effort was made to ensure that the information in this document was complete and 

accurate at the time of printing. Information is subject to change.

Содержание IA500 Series

Страница 1: ...800 205 7186 www codeblue com IA500 Models 500 d 500 s 501 d 501 s Administrator Guide Installation Setup ...

Страница 2: ...mming 11 7 2 Basic Programming Mode 11 7 3 Additional Programming Commands 13 8 Audio Programming Mode 15 8 1 Audio Program Effects 16 9 Auxiliary Relay 1 Output using Command 6 17 10 Remote Mount Beacon Strobe Installation 18 11 Troubleshooting 19 12 Technical Specifications 20 13 Maintenance Schedule 21 14 Warranty 23 15 Download Information 24 Note The IA500 has been discontinued or end of life...

Страница 3: ...in monitoring for Areas of Rescue functionality and live audio setup programming These line powered phones feature single or dual solid state button activation two high intensity LED indicators a cast metal bezel assembly and stainless steel housings for surface or flush mount applications The InterAct 500 series has conformal coated electronics to support both indoor and outdoor installations Eac...

Страница 4: ...ler or end user to pro gram the unit from a phone on site or from a remote location 3 1 Construction Surface Mount The IA500 housing shall be constructed of 16 gauge stainless steel and measure 7 375 W x 7 125 H x 2 D and weigh approximately 5 lbs The housing shall consist of two pieces permitting the backplate to be mounted during the rough in and the faceplate installed during completion The bac...

Страница 5: ...equired To analog telephone service If loop current is found to be less than ideal use either a Ring Voltage Booster or a Long Loop Adaptor Ref Proctor 46222 Optional Strobe 40197 12V DC 180ma Product wiring diagram reasonably represents current offering and is intended to assist in component identification and service Earlier product production may have different components and wiring connections...

Страница 6: ... wire 4 8 screw fasteners To install the IA500 first remove the two retaining screws Allen wrench provided from each side of the case Remove the rear mounting plate by sliding it downward Using the mounting plate as your guide on the wall mark the mounting hole and conduit hole locations on the wall Remove the rear mounting plate and create the required holes along with any conduit you choose to u...

Страница 7: ...crews from the back box 2 Using the back box as your guide on the wall mark the rough opening size 3 Create the required opening and conduit runs 4 Pull CAT 3 cable through the conduit hole in the back box 5 Connect CAT 3 cable to the Ethernet port on the PCB 6 Attach faceplate to back box 7 Replace the four faceplate screws Vertical Orientation 5 2 IA501 ...

Страница 8: ...e 2 0 INSTALLATION PROCEDURES Curb Mounts should be mounted on concrete bases with a depth of 4 5 inches using the correct mounting bolts for your application Mounting Holes In order to comply with the Americans with Disabilities Act ADA of 1990 the speakerphone button s should be positioned between 34 and 48 inches from grade level Consult an ADA specialist in your area to verify local and federa...

Страница 9: ... 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com GU 144 M page 9 of 24 IA500 Administrator Guide Specifications subject to change without notice or obligation on the part of the manufacturer ...

Страница 10: ...ring down or hotline service you must enter 99 to clear the factory default settings In some installations you may find the phone will not answer when called and the phone line you re using goes into reorder tones This is an indication the line current is below minimum to ring the phone If this is the case do the following Locate the jumper on the bottom of the PCB board below the barrier strip Re...

Страница 11: ...swering the unit will emit a short beep 3 The unit automatically enters Monitoring Mode see previous page 4 You have two minutes to select Basic Programming or Audio Programming Mode as well as the option to issue additional commands during this interim such as Reset programming see Figure 1 on the following page 5 To enter into Basic Programming Mode dial the unit s default password 2 2258 NOTE I...

Страница 12: ...e phone will hang up and dial the next number assigned to the Red button The unit will cycle through to the last number in memory for the HELP button i e 1 6 9 231 555 1212 The unit will cycle through the number twice since the default is set to 2 Command 05 Figure 3 NOTE In this case the first digit reflects that the Red button 1 has been assigned to the sixth memory location 6 and further the ph...

Страница 13: ...r and Calling Cycle among others 6 If the command is programmed correctly the unit will emit a single beep an incorrect entry will trigger a triple beep 7 Dial 99 to reset all programming functions Figure 1 Continued on next page Button Assignments Memory Slot Phone Number Examples while in Programming Button Assignment Variations 1 RED button 1 123 456 7890 1 1 1234567890 RED Button first assignm...

Страница 14: ...mited to quality of line conditions 05 99 sec 30 sec To increase the ring timer from 30 to 35 sec dial 04 35 05 Calling Cycle Determines how many times each number in memory is dialed before the IA500 resets to stand by state NOTE Limited to quality of line condi tions 1 3 times 2 Decrease the calling cycle from 2 to 1 by dialing 05 1 07 Contact Closure Relay Relay Programming 2 Modes Available Mo...

Страница 15: ...e unit automatically enters Monitoring Mode 4 You have two minutes to initiate Audio Programming Mode 5 Dial 8 2258 to enter into live monitoring mode a As described in the chart on page 14 Figure 4 command options include Speaker Level Microphone Sensitivity and Background Noise Filter among others 6 If the programming command is correct the unit will emit a single beep an incorrect entry will tr...

Страница 16: ...itivity of the microphone b Dial 82 02 to decrease the Microphone Sensitivity and continue to modify as necessary option range is 00 15 Figure 4 2 Speaker Volume Too Low a Increase the Speaker Output Level by changing Command 81 to 81 12 option range is 00 15 Figure 4 3 NOTE If the phone line is weak this command change may produce a negative condition 4 Phone Line Receive Gain a Occasionally when...

Страница 17: ...e 4 1 If not already in programming mode call the IA500 by dialing its assigned phone number or extension 2 Upon answering the unit will emit a short beep 3 The unit automatically enters Monitoring Mode 4 You have two minutes to initiate Basic Programming Mode 5 Dial 2 2258 or appropriate password to enter into programming mode 6 Modify the Contact Closure Relay by dialing 07 xx where xx equals th...

Страница 18: ... the strobe J to the round portion of the strobe bracket NOTE If the beacon strobe is mounted upside down a drain hole must be drilled into the lens to prevent it from filling with water 3 0 ATTACH LIGHT AND BRACKET TO THE J BOX 4 1 Connect all wiring from the strobe to the wiring from the unit inside of the J box using wire nuts 4 2 Attach strobe bracket to the J box using four 6 32 X screws as s...

Страница 19: ...not an issue Note 0 0 AC DC Curren t Com AC DC Volts Code Blue Phone Telephone Tip Ring Analog POTS Line Source Tip Ring Testing Loop Current Interrupt one wire of the pair and connect through your Amp Meter as diagrammed Set your meter on mA DC range Either call the Code Blue Phone or Activate the Code Blue Phone and note the mA reading once the connection to the party has been made The IA3100 Mi...

Страница 20: ...ctions Individual phone lines or PBX extensions recommended Environmental Operating Tempera ture Range 220 to 1500 F Operating Relative Humidity 0 to 95 RH Non condensing Electrostatic Dis charge 20kV Faceplate Stainless steel piezoelectric weatherproof button microphone and speaker openings reduce damage from vandalism waterproof 3 speaker waterproof microphone Physical Dimensions face plate IA 5...

Страница 21: ...tions are tight and clean Verify no stains exist around gasket areas Stains indicate leaking and gasket should be replaced Verify moisture weep hole on cabinet bottom is open and unobstructed Verify bottom of bollards are at least 1 2 inch above footing and free of obstructions Only applies to CB 1 CB 5 and CB 9 units Apply automotive paint sealant to unit exterior for protecting finish against en...

Страница 22: ...e Blue units an appropriate surface maintenance schedule should be adhered to The Surface Care Frequency table below provides general guidelines to assist in configuring a schedule Please note that the frequency of care required to guard the Code Blue unit s surface from damage will also be dictated by local environmental characteristics Low ê ê Low Moderate ê êê ê Moderate ê êê êê ê Moderate High...

Страница 23: ...his product Refer to your sales agreement to establish the terms In addition Code Blue s standard warranty language as well as information regarding support for this product while under warranty is available at www codeblue com support Notice Every effort was made to ensure that the information in this document was complete and accurate at the time of printing Information is subject to change ...

Страница 24: ...urces guides 8 Phone Enclosures Administrator Guide www codeblue com resources guides 9 Stainless Steel Maintenance Guide www codeblue com support 10 IA4100 Administrator Guide www codeblue com resources guides 11 IP5000 Administrator Guide www codeblue com resources guides 12 IP1500 2500 Administrator Guide www codeblue com resources guides 13 ToolVox X3 Administrator Guide www codeblue com resou...