Code Blue
•
259 Hedcor Street
•
Holland, MI 49423 USA
•
800.205.7186
•
www.codeblue.com
GU-144-M
page 14 of 24
IA500
Administrator Guide
Commands Feature
Description
Command
Range
Default Example
02
Programming
Password
The programming pass-
word can be changed from
default to your choice of
numbers up to 8 digits in
length.
0-8 digits
2258
To modify the default password to
98765, from the keypad, dial: 02-
98765-#
03
Call Length
Timer
Sets duration of the call.
This can be modified to ac
-
comodate the end user.
1-99 min.
10 min. To increase the call length duration
from 10 to 25 min., dial: 03-25-#
04
Ring Timer
Ring Timer controls the
amount of time the IA500
is allowed to ring a called
party before the phone
rolls over to dial the next
programmed number
(NOTE: Limited to quality
of line conditions).
05-99 sec.
30 sec.
To increase the ring timer from 30
to 35 sec. dial: 04-35-#
05
Calling Cycle Determines how many
times each number in
memory is dialed before
the IA500 resets to stand-
by state (NOTE: Limited
to quality of line condi
-
tions)
1-3 times
2
Decrease the calling cycle from 2
to 1 by dialing: 05-1-#
07
Contact
Closure Relay
Relay Programming: 2 Modes Available
Mode 1:
Default. Closed
for the duration of the call
and is uniquely linked to
the RED BUTTON activa-
tion only.
Duration of Call 10 min.
Mode 2:
Relay Gate
Control. This feature
disengages the relay from
the RED BUTTON rela-
tionship, but
ONLY
when
Command 07 has been
programmed with a time
period. To control the
relay remotely, the opera-
tor needs to use the “6” on
the keypad to request the
contact closure for the time
period pre-programmed.
00-99 sec.
none
To force contact closure for 2 sec.
dial: 07-02-#, or for a contact clo-
sure of 60 sec. dial: 07-60-#
Figure 3