18 CB 5-s with Decorative Top Installation Instructions
1.0 FOUNDATION
– (see anchor bolt installation instructions)
2.0
SET THE UNIT
2.1
Screw one set of nuts and washers onto the anchor bolts
– After the foundation has set,
screw one set of nuts followed by one set of washers onto the anchor bolts. Set the nuts such
that the lowest washer is about 2½ inches above the concrete at an even height. To accom-
plish this, use a small level and check all three directions. These nuts are not adjustable after
the unit is in place. The bottom edge of the Code Blue unit will be ½-inch above the concrete
when installed.
IMPORTANT:
The leveling of the bottom nuts is crucial to the leveling of the unit. A small error
in the adjustment of these will be magnified after installation.
IMPORTANT:
A ½-inch air gap is required between the foundation and the unit. Moisture
problems may result if this condition is not complied with.
2.2
Set the Code Blue unit on the anchor bolts
– Align the phone plate in the desired direction,
and lift the Code Blue unit over the anchor bolts. Note that the unit weighs approximately 240
pounds. Use appropriate lifting materials and methods to avoid possible injury and/or damage.
2.3
Secure the Code Blue unit
– Access the mounting studs through the door on the side of the
unit and tighten the mounting nuts onto the anchor bolts. This may be more convenient if a
long socket, extension and universal joint is used to tighten the hardware.
3.0 INSTALL LIGHT HOUSING WITH COMBINATION BEACON/STROBE
3.1
Connect the cords
– Plug the wires from the beacon/strobe into the mating plug at the top of
the pedestal.
3.2 Fasten the light housing assembly. Using the supplied screws, fasten the housing assembly
to the light base on the pedestal top.
4.0 WIRING
4.1
Ground
– The ground (green) wire should be stripped and fastened to the supplied grounding
lug.
4.2
24V AC supply
– Using the proper crimping tool, attach a #8 fork to each of the incoming
power wires and fasten them to the terminal screws labeled “24V AC.”
4.3
120/240V AC supply
– Using the proper crimping tool, attach a #8 fork to each of the incom-
ing power wires and fasten them to the correct terminals as labeled on the transformer. After
completing the wire connections install the supplied terminal covers.