3 Getting Started
Basic Install Instructions
1.
EIA/TIA, ANSI, CSA and BICSI cabling or similar standards shall be adhered to for proper
operation of Code Blue communication devices connected to copper or fiber infrastructures.
Communications cable and electrical cable in the same conduit is not an acceptable instal-
lation and shall not be supported. Analog phones require a minimum of 23mA for proper
operation (26-29mA recommended).
2.
Each analog speakerphone requires its own phone line or PBX extension. Multiple units
shall not be supported.
3.
Speakerphones require programming before operation. Consult the User Guide or
Administrator Guide enclosed with the unit or go to
www.codeblue.com > Support >
Downloads
to read or download manuals.
4.
If you are installing IP speakerphones, please read the appropriate manuals and consult
with your Network
Administrator.
5.
Size electrical wiring based on length of run.
6.
Consult the enclosed document packet for internal wiring instructions.