Code Blue
•
259 Hedcor Street
•
Holland, MI 49423 USA
•
800.205.7186
•
www.codeblue.com
GU-149-B
page 16 of 33
CB 2 Series
Administrator Guide
4.3 CB 2-e with AED Housing Installation Instructions
Pre-Installation
Electrical preparation
– The unit may have supply wires run either behind the unit through the wall
or below the unit by using an external conduit through the bottom of the unit. Holes in the back and
bottom of the unit have been provided for this purpose.
Installation Procedures
1. Remove the top of the unit.
2. Mark the mounting holes
– In order to comply with the Americans with Disabilities Act
(ADA) of 1990, the speakerphone button(s) should be positioned between 34 and
48 inches from grade level. (Consult an ADA specialist in your area to verify local and
federal guidelines.)
3. Drill all marked holes.
4. Install the housing
– Four anchors of appropriate size and type should be used to
fasten the housing to the wall.
IMPORTANT:
If wiring is being supplied from the back, ensure that the conduit is aligned at
this time.
5. Reattach the top.
Wiring
120/240V AC supply
– Feed the incoming power leads into the supplied J-Box. Connect the ground
to the supplied grounding lug. Connect the neutral to the orange lead for fusing the unit. Connect the
load to the black wires. After completing the wire connections, install the supplied J-Box cover and
ensure all cord grips are secure.