Code Alarm PROFESSIONAL SERIES Скачать руководство пользователя страница 1

1

2020 Voxx Electronics Corporation. All rights reserved.

PROFESSIONAL

SERIES

Security and Keyless Entry

 Installation Guide

ca1155

**This guide is a reference for module firmware version 5.0 or higher**

Содержание PROFESSIONAL SERIES

Страница 1: ...1 2020 Voxx Electronics Corporation All rights reserved PROFESSIONAL SERIES Security and Keyless Entry Installation Guide ca1155 This guide is a reference for module firmware version 5 0 or higher ...

Страница 2: ...gramming 13 Transmitter Programming 13 Manual Feature Programming 13 Programming Feature Banks 14 PC Based Feature Programming Firmware Updates Optional 15 Adjusting the Shock Sensor 16 Testing the Shock Sensor 16 Dome Light Delay Theater Dimming 16 Chirp Delete User Accessible 17 User Selectable LED 17 Feature Descriptions 17 Transmitter Button Functions 22 Security Trigger Zones 22 System Layout...

Страница 3: ...s near hot surfaces Avoid mounting components or routing wires near moving parts Tape or loom wires under hood for protection and appearance Technical Support 800 421 3209 or go to www voxxuniversity com Use a Digital Multi Meter for testing and verifying circuits DO NOT USE A TEST LIGHT OR COMPUTER SAFE PROBE as these can set off air bags or damage vehicle computers Use grommets when routing wire...

Страница 4: ...ITE PARKING LIGHT OUTPUT 9 WHITE RED PARKING LIGHT INPUT 10 WHITE PARKING LIGHT OUTPUT 11 VIOLET LOCK POLARITY 87 12 BLUE BLACK UNLOCK MOTOR 30 12 PIN MAIN POWER LOCKS 1 PURPLE DOOR TRIGGER INPUT 2 GREEN BLACK FACTORY DISARM OUTPUT 3 OPEN 4 GREEN DOOR TRIGGER INPUT 5 ORANGE GROUND WHEN ARMED OUTPUT 6 BROWN BLACK HORN OUTPUT 7 VIOLET BLACK AUX 1 8 GRAY HOOD PIN INPUT 9 YELLOW IGNITION INPUT 10 RED ...

Страница 5: ...d connect to the RED wire on the siren NOTE Be sure to loom the siren wires and seal the grommet 3 BLACK GROUND Connect the BLACK wire to a solid chassis ground point using a ring terminal and self tapping screw not supplied Scrape away paint from the grounding point to ensure a good connection The recommended grounding point is a metal surface in the driver s side kick panel area NOTE Do not grou...

Страница 6: ... source Connect the WHITE wire to the parking light output wire Negative switching Parking Lights Connect the WHITE RED wire to a good chassis ground Connect the WHITE wire to the parking light output wire 4 BROWN BLACK UNLOCK SWITCH 87A Refer to the Door Lock Section on page 11 of this guide 5 VIOLET BLACK UNLOCK POLARITY 87 Refer to the Door Lock Section on page 11 of this guide 6 WHITE BLACK LO...

Страница 7: ... Electronics Corporation All rights reserved 12 BLUE BLACK UNLOCK MOTOR 30 Refer to the Door Lock Section on page 11 of this guide 11 VIOLET LOCK POLARITY 87 Refer to the Door Lock Section on page 11 of this guide ...

Страница 8: ...e Verification This wire will register ground NEG when the door is opened and the interior light is on This wire will register positive voltage when the door is closed and the interior light is off Connect the GREEN wire to the vehicle s negative door input wire s NOTE Certain vehicles may require multiple connections Refer to vehicle application guide 2 GREEN BLACK FACTORY DISARM This wire will s...

Страница 9: ...N INPUT Install a Hood Pin Switch and connect to the GRAY wire Verification This wire when connected will register ground when the vehicle s hood is opened Connect the GRAY wire to the hood pin NOTE Be sure to loom the wire and seal the grommet 6 BROWN BLACK HORN OUTPUT Locate the vehicle s horn wire Verification This wire will register at positive voltage and register ground when the horn switch ...

Страница 10: ...TRUNK RELEASE OUTPUT Locate the vehicle s trunk release wire at the trunk release switch Verification This wire will register either positive voltage or ground when the trunk release is activated This is a low current output 300mA ...

Страница 11: ...e wire that provides a ground signal from the factory door unlock switch to the factory door lock control relay Connect the VIOLET and the VIOLET BLACK wires to a solid chassis ground point The WHITE BLACK and BROWN BLACK wires are not required for this type of door lock unlock system 3 Wire Positive Switched Door Locks Connect the GREEN BLACK wire to the wire that provides a 12 volt signal from t...

Страница 12: ... to confirm the drill will not damage any existing components as it passes through the panel Drill a 1 4 hole and pass the red and blue wires from the LED through the hole from the front of the panel Firmly press the body of LED into the hole until fully seated Additional Ports Programming Valet Button Port Select a mounting location that is within reach of the ignition switch as this switch in co...

Страница 13: ...ss and hold the valet override button 3 Within 10 seconds the system will chirp 3 three times 4 Press 1 button of each transmitter you wish to program 5 The system will respond with 1 chirp for each accepted transmitter 6 Pressing the override button at anytime during programming will advance to the next bank NOTE The system will exit transmitter programming after 15 seconds of inactivity NOTE Thi...

Страница 14: ...M Remote Start 7 Anti Hijack Mode OFF ON 8 Ground While Armed Orange Output Ground While Armed Ground While Disarmed 9 DBI Port Protocol DBI ADS 10 Arm Disarm Chirps Standard 2 Arm 1 Disarm Inverted 1 Arm 2 Disarm 11 LED Indicator ON OFF 12 Auto Re lock OFF Lock Only Arm Lock 13 Extended Parking Lights OFF After Unlock After Lock After Lock Unlock 14 Parking Light Relay Trunk Output Standard Inver...

Страница 15: ... Press 5 Horn Output Timing 16mS 10mS 30mS 40mS 50mS 6 Real Panic ON OFF 7 AUX 1 Violet Black Output Push and Hold Latched Latched until IGN ON Dome Light Output PC Based Feature Programming Firmware Updates optional When using the NEW Code Alarm Utility App along with a VEPROG Programming tool you may program selectable features or update the firmware of this module To Use a PC and VEPROG tool fo...

Страница 16: ... system will then monitor the door trigger wire Once the dome light turns off the system will then add 2 seconds and then exit the learning mode 4 The LED will begin to flash indicating the system has exited the learning mode and is now armed Note To program a custom delay time Feature Bank 2 Feature 16 Dome Light Delay Preset Time or Programmable must be set to OFF Program Custom Time Defaulting ...

Страница 17: ...rming must also be set to passive 3 System Arming Determines manual or automatic locking of the vehicle s doors Active Requires use of the transmitter to arm the security system Passive Automatically arms the security system 1 minute after the last door is closed Feature Descriptions Chirp Delete User Accessible System ARM DISARM chirps can be toggled ON or OFF without entering the programming fea...

Страница 18: ...red again 6 Security Controls security functionality ON OFF ON Full security functionality OFF The security system does not trigger Panic and all other convenience features operate as normal ON w OEM Remote Start Compatibility This will prevent a vehicle s factory remote start from triggering the security system when activated The system will use the ignition input to shunt shock and door inputs u...

Страница 19: ...Lock Only The unit will re lock the vehicle after 3 minutes if the system was disarmed and a door was NOT opened within that time Arm Lock security units only The system will arm and also re lock the vehicle after 3 minutes if the system was disarmed and a door was NOT opened within that time 13 Extended Parking Lights When selected this feature will keep the parking lights on for an additional 30...

Страница 20: ...actory Disarm 2x 500mS Double 500mS second pulse with unlock and remote start activation Factory Disarm 350mS Single 350mS second pulse with unlock and remote start activation Factory Disarm 500mS Single 500mS second pulse with unlock and remote start activation Factory Disarm w Unlock Timing Uses the timing option set for Unlock in Bank 3 Feature 1 16 Dome Light Delay Preset Time or Programmable ...

Страница 21: ...turned ON Latched ON until Button Press Continuous output until the activation button is pressed again 5 Horn Output Timing Control the minimum horn pulse time in milliseconds some vehicle will require a longer pulse to activate the factory horn 16mS 10mS 30mS 40mS 50mS 6 Real Panic Controls the panic out when triggered from the transmitter ON Randomized horn honks when panic is triggered OFF Stan...

Страница 22: ...hes Hood Trunk Input 3 Flashes Door Input 4 Flashes Shock Sensor 5 Flashes Ignition Input 4 Button Transmitter Lock Unlock Trunk Car Find Panic Operation Method Lock X Press and Release Unlock X Press and Release Trunk X Push and Hold 3 Sec Car Finder X Press and Release Panic X Push and Hold 3 Sec AUX 1 X X Push and Hold 3 Sec Shock Bypass X X Press and Release Lock then Press Lock Car Find withi...

Страница 23: ...SWITCH 87A BLUE BLACK UNLOCK MOTOR 30 4120402 PURPLE DOOR TRIGGER INPUT GREEN BLACK FACTORY DISARM OUTPUT OPEN GREEN DOOR TRIGGER INPUT ORANGE ARMED OUTPUT BROWN BLACK HORN OUTPUT VIOLET BLACK AUX 1 OUTPUT GRAY HOOD PIN INPUT YELLOW IGNITION INPUT RED WHITE TRUNK RELEASE OUTPUT 4120403 1024363 1024389 RED BATTERY 12V BLACK GROUND WHEN ARMED BLUE FULL TRIGGER GREEN WARN AWAY TRIGGER SHOCK SENSOR HA...

Страница 24: ...dustry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including any interference that may cause undesired operation Warning Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment ...

Отзывы: