4
* Throughout this manual, ‘press’ refers to pressing for less than 1 second; ‘press and hold’ refers to
pressing for more than 1 second.
†
If you have chosen the Silent Arming Option, the siren will not sound when arming or disarming until the
appropriate button is pressed a second time.
Arming the Security System
To arm the system, exit the vehicle, close all doors, then press* the
ARM button. The horn/siren will “chirp” twice
†
and the parking lights
will flash twice, indicating the system is armed. The doors will also
lock at this time (if equipped and connected). The status indicator (red
warning light on the dash) will blink steadily, once per second.
Pre-arm Mode
If the horn/siren “chirps” and the parking lights flash only once, this
indicates that the vehicle courtesy light is on, or that an entrance is
not closed securely. Check to see that doors, hood, and trunk are
properly closed. Once all entrances are secured (and the courtesy
light is off), the system will “chirp” / flash again. The system is now fully
armed. (If the entrance is not secured within 4 minutes, the system will
arm and ignore the unsecured entrance until it is closed.)
Disarming the Security System
To disarm the system, press the DISARM button. The horn/siren will
“chirp” once and the parking lights will flash once, and the doors will
unlock.
The courtesy light will turn on for 1 minute, or until the vehicle is started.
Attempted Intrusion Identification
If the horn/siren “chirps” four times
when disarming, this indicates that the
system was triggered in your absence.
The status indicator will also flash
rapidly. Perform the following operation
to determine the protected zone that
triggered the system:
After disarming, press the emergency override button.
The horn/siren will “chirp” to indicate the cause of the alarm trigger:
1 chirp IT-s Interior Theft Sensor
2 chirps Door
3 chirps Hood
4 chirps Trunk/Optional Sensors
5 chirps Ignition was turned on
Using Your Remote Transmitter
Press both ARM and
DISARM for Panic
Press to DISARM
Security System and
Unlock Doors
Press and HOLD for
TRUNK
Press to ARM the
Security System and
Lock Doors
13
Programming Selectable Options, cont’d
Default settings in BOLD
OPTION
DESCRIPTION
Option Bank 0 - 3 Chirps (Learn Transmitters)
Option Bank One - 4 Chirps (Keyless & Alarm Options)
STATUS INDICATOR
1. Lock with Ignition
Doors lock when all doors are closed and
ON
OFF
ignition is turned on
2.Unlock with Ignition
Doors unlock when ignition is turned off
ON
OFF
3.Delayed Door Lock
3 sec. delay locking for theater dimming
ON
OFF
4.Extended Locks
Lock duration is (1) 5 sec. or (2) 0.6 sec.
ON(1) OFF(2)
5. Double Unlock Pulse
Unit provides two pulses on each unlock
ON
OFF
6. Passive Arming
Alarm automatically arms 60 sec.
ON
OFF
after ignition is turned off
Option Bank Two - 5 Chirps (Chirps)
1. Silent Choice
(1) Horn Chirps 1st Press (2) Second Press
ON(1) OFF(2)
2.Chirp Delete Deletes ARM/DISARM chirps
ON
OFF
3. Horn Pulse
(1) RPS (2) Pulsed
ON(1) OFF(2)
4. Door Trigger Polarity
(1) Positive (2) Negative
ON(1)
OFF(2)
5. Iluminated Entry (1) Dome (2) Armed out
ON(1) OFF(2)
6. Siren/Horn
(1)RPS (2)Siren
ON(1) OFF(2)
7. Light Touch adj ARM raises sensitivity; DISARM lowers sensitivity
ON OFF
4. Full Shock adj
ARM raises sensitivity; DISARM lowers sensitivity
ON
OFF