3 Wire Positive Switched Door Locks:
In this application, the GREEN wire of the two pin harness provides a + 12 volt pulse during the disarming se-
quence, or pulsed 12 volt unlock output. Connect the GREEN wire to the low current 12 volt signal wire from the
factory door unlock switch to the factory door unlock relay.
The BLUE wire of the two pin harness provides a + 12 volt pulse during the arming sequence or pulsed 12 volt lock
output. Connect the BLUE wire to the low current 12 volt signal wire from the factory door lock switch to the factory
door lock relay. See Below For Wiring Detail.
3 Wire Positive Switched Door Lock/Unlock Wiring Detail
.
3 Wire Ground Switched Door Lock Circuits:
In this application, the GREEN wire of the 2 pin harness provides a ground pulse during the arming sequence, or
pulsed ground lock output. Connect the GREEN wire to the low current ground signal wire from the factory door lock
switch to the factory door lock relay.
The BLUE wire of the 2 pin harness provides a ground pulse during the disarming sequence, or pulsed ground
unlock output. Connect the BLUE wire to the low current ground signal wire from the factory door unlock switch to the
factory door unlock relay. See Below For Wiring Detail.
3 Wire Ground Switched Door Lock/Unlock Wiring Detail
9
Lock
Unlock
Door Lock Switch
Vehicle Door Lock
Control Relays
GREEN (-) Lock Output
BLUE (-) Unlock Output
Lock
Unlock
Door Lock Switch
Vehicle Door Lock
Control Relays
BLUE (+) Lock Output
GREEN (+) Unlock Output
Содержание CA-500