background image

4

Auxiliary A-H Push-Buttons -

 As configured by the   Siren Configuration Software, eight on/off Auxiliary push-buttons are readily accessible for 

controlling the Auxiliary outputs of the Amplifier. Each Auxiliary push-button can be custom labeled with the supplied label kit. Each push-button is 

backlighted when activated to alert the operator. The default setting is for each Auxiliary push-button to control the corresponding Auxiliary output of 

the Amplifier. Auxiliary A through F supplies power to the load through the connector pins labeled A thru F. Auxiliary G and H supplies power with a 

positive or ground voltage to the load through the connector pins labeled G and H.

3-Level Switch - 

The Control Head provides a 3-Level switch for changing the emergency warning mode. The 3-Level switch is located in the top left 

corner of the control head. When the 3-Level switch is switched to the far left position, the unit is off. When the 3-Level switch is in the first position 

from the left, the level 1 configuration of the lights is turned on. When the 3-Level switch is in the second position from the left, the level 1 & 2 con-

figuration of lights are turned on. When the 3-Level switch is in the third position from the left, the level 1, 2, & 3 configuration of the lights are turned 

on. Level 1, 2, & 3 activate the LightAlert if supplied. These default settings can be altered using the   Siren Configuration Software. The 3-Level 

switch may be overridden by other push-buttons. If the push-buttons are programmed to a higher level than the position of the 3-Level switch, the 

push-buttons will take precedence. If the push-buttons are programmed to a lower level than the position of the 3-Level switch, the 3-Level switch will 

take precedence. The lighting can be set to various levels for the WAIL, YELP, ALT TONE, MANUAL, and AUX push-buttons. Visit these sections in 

the configuration software to set these preferences.

3-Color Status LED - 

Three LEDs are visible on the front of the remote siren amplifier. When the 3-Level switch is set to Level 1 the green LED 

lights. When the siren is set to Level 2 both the green and yellow LEDs light. When the siren is set to Level 3 the green, yellow, and red LEDs light. 

These LEDs indicate the level of the siren and controls. These Levels are configurable in the   Siren Configuration Software User Manual.

Hands-Free -

 Hands-Free mode is directly linked to the Auxiliary push-buttons. By default, the Hands-Free mode is disabled. When an Auxiliary 

push-button is configured for Hands-Free and that Auxiliary push-button has been turned on, the Hands-Free mode is active but waiting for an initial 

press of the horn ring to activate the WAIL push-button. A second press of the horn ring will activate the YELP push-button. Pressing the horn ring a 

third time will activate the ALT TONE push-button. A fourth press of the horn ring will return to the WAIL push-button. This type of scrolling will con-

tinue until the user deactivates the Hands-Free Scroll. Pressing the Auxiliary push-button turns off the sound and deactivates the Hands-Free Scroll. 

Pressing and holding the horn ring will turn off the sound but leave Hands-Free Scroll in the active mode. The Remote input and Manual push-button 

can also be configured for multiple functions during Hands-Free mode. Please refer to Z3 Siren Configuration Manual for details. See Table on page 

6 for factory settings.

Horn Ring -

 The siren accepts either a positive or a ground signal into the Horn Ring input on the Amplifier. The Horn Ring signal is disconnected 

from the vehicle and connected to the Horn Ring input of the Amplifier. The Horn Relay wire is then run from the Amplifier to the horn of the vehicle. 

This allows the Horn Ring to execute some of the user selectable functions of the   Siren. The Horn Ring can be configured to multiple functions in 

the Siren Active and Siren Inactive modes of operation. The Horn Ring is set to Scroll in the Hands-Free mode and cannot be changed. Please see 

the   Siren Configuration Software User’s Manual for details.

Horn Ring Transfer -

 The Horn Ring Transfer allows the Horn Ring to be disabled from the vehicle horn and the controls transferred to control other 

siren tones. The Horn Ring Transfer can be set to occur at Level 1, Level 2, Level 3, or any combination of the three.

Remote -

 The siren accepts either a positive or a ground signal into the Remote Input wire on the Amplifier. This Remote Input wire is usually con-

nected to a user supplied switch. The siren is factory set for a ground signal. The Remote input can be configured to multiple functions in the Siren 

Active, Siren Inactive, and Hands-Free modes of operation. Please refer to the   Siren Configuration Software User’s Manual for details. See Table 

on page 6 for factory settings.

Hit-N-Go -

 Hit-N-Go only works when a siren tone is active. Once a siren tone is active, Hit-N-Go is activated simply by pressing the Horn Ring 

(Vehicle Horn Control) or pressing the Remote input. It will go to the Override tone for 8 seconds and then return to the primary tone. The actual tone 

for the Hit-N-Go depends on which push-button is active. If the WAIL push-button is active then the Hit-N-Go (Override) tone is the Yelp tone. If the 

YELP push-button is active then the Hit-N-Go tone is the Hyper-Yelp 1 tone, and if the ALT TONE push-button is active then the Hit-N-Go tone is the 

Hyper-Lo 1 tone. These Override tones are user configurable in the Configuration Software. The siren can also be configured so the MANUAL push-

button is Hit-N-Go activator.

Scroll -

 Scroll only works when a siren tone is active. Once a siren tone is active, Scroll is activated simply by pressing the Horn Ring (Vehicle Horn 

Control) or pressing the Remote input. The Scroll Mode will cause the siren to cycle through the WAIL, YELP and ALT TONE push-buttons. For 

example, if the WAIL push-button is active and the Horn Ring (configured to scroll) is pressed, the YELP push-button will become active. Another 

press of the Horn Ring will activate the ALT TONE push-button. Another press of the Horn Ring will return to activate the original WAIL push-button.  

The siren can also be configured so the MANUAL push-button activates the Scroll. NOTE: Pressing and holding the Horn Ring for more than a half 

second will cause the   Siren to generate the Air Horn tone.

Scroll On/Off -

 The Scroll On/Off mode works like the Scroll mode except the   Siren will scroll the primary tones through an off state. The   Siren 

will scroll from Wail to Yelp to Alt Tone to off and then back to Wail. The Remote input can be configured to activate Scroll On/Off. NOTE: Pressing 

Содержание Z3 Series

Страница 1: ... the siren sound outside of vehicle Contents Introduction 2 Standard Features 2 Control Head Configurable In Vehicle 3 Computer Configurable 3 Not Configurable 5 Unpacking Pre installation 7 Installation Mounting 7 Amplifier Connections 8 Amplifier Power Distribution 9 Control Head Connections 9 Conventional ArrowStik Connections 10 Troubleshooting 12 Siren Wiring Diagram 14 Siren Specifications 1...

Страница 2: ...the operator so that he can operate the system without losing eye contact with the roadway Emergency warning devices often require high electrical voltages and or currents Properly protect and use caution around live electrical connections Grounding or shorting of electrical connections can cause high current arcing which can cause personal injury and or severe vehicle damage including fire PROPER...

Страница 3: ... Push Button This push button produces the Wail tone when pressed By default it also turns on the Level 3 lights but this is configurable to Level 2 Level 1 or no lights The override tone is also configurable for this feature Pressing the push button a second time turns this feature off Operation of this feature is affected by SirenLock 3 Level Switch and Park Kill features See these sections for ...

Страница 4: ...nput and Manual push button can also be configured for multiple functions during Hands Free mode Please refer to Z3 Siren Configuration Manual for details See Table on page 6 for factory settings Horn Ring The siren accepts either a positive or a ground signal into the Horn Ring input on the Amplifier The Horn Ring signal is disconnected from the vehicle and connected to the Horn Ring input of the...

Страница 5: ...oft ware It can be enabled during configuration of the siren This feature requires user provided current sense module for the lights SirenLock By default the SirenLock feature is disabled With SirenLock disabled the Siren will be in a Siren Active mode of operation and this will disable the Siren Inactive Function for the Horn Ring input Remote input and Manual push button In the Siren Configurati...

Страница 6: ...y 1 Minute 3 Level Switch Off Auxiliary Push Buttons Off ArrowStik Off LoadMGR Off Group 2 Voltage Fault Threshold 11 00 Volts Dropout Delay 1 Minute 3 Level Switch Off Auxiliary Push Buttons Off ArrowStik Off LoadMGR Off Group 3 Voltage Fault Threshold 10 50 Volts Dropout Delay 1 Minute 3 Level Switch Off Auxiliary Push Buttons Off ArrowStik Off LoadMGR Off Overvoltage Protection Enabled SirenLoc...

Страница 7: ... in SAE Standard J1849 For example electronics designed for interior mounting should not be placed underhood etc Controls should be placed within convenient reach of the driver or if intended for two person operation the driver and or passenger In some vehicles multiple control switches and or using methods such as horn ring transfer which utilizes the vehicle horn switch to toggle between siren t...

Страница 8: ...the manufacturer and be protected from moving parts and hot surfaces Looms grommets cable ties and similar installation hardware should be used to anchor and protect all wiring Particular attention should be paid to the location and method of making electrical connections and splices to protect these points from corrosion and loss of conductivity Ground terminations should only be made to substant...

Страница 9: ...0 Amp fuse installed inside the Amplifier Fuses may be accessed through the panel on top of the Amplifier The Auxiliary outputs A B C and D can supply a maximum of 5 amps each Auxiliary outputs E F G and H can supply a maximum of 10 amps each The combined total for all Auxiliary outputs is 50 Amps Auxiliary outputs A B C and D have 7 5 amp fuses and Auxiliary outputs E F G and H have 15 amp fuses ...

Страница 10: ...range Brown The Right Arrow travels from Blue to Brown The Left Arrow travels from Brown to Blue 6 HEAD HARNESS CONNECTIONS When viewing the vehicle from the rear the ArrowStik harness is connected in the following order from Driver side to Passenger side Yellow Gray Green Violet Tan Orange The Right Arrow travels from Yellow to Orange The Left Arrow travels from Orange to Yellow If the Siren Arro...

Страница 11: ...11 Figure 6 Figure 7 NON CC WIRING CONNECTIONS Figure 8 CC WIRING CONNECTION ...

Страница 12: ...ES A THERE IS A SHORT IN THE WIRING OR THE LOAD IS GREATER THAN 1 AMP A CHECK FOR SHORTS INSTALL INTER CLEAR BOOSTER KIT PART INTBS P A VOLUME LOW OR NO P A AT ALL A INCREASE P A VOLUME B MICROPHONE NOT COMPLETELY PLUGGED IN C DEFECTIVE MICROPHONE D COMMON MICROPHONE CIRCUIT NOT PROPERLY WIRED E INCORRECT MICROPHONE A REFER TO SETUP AND ADJUSTMENT SECTION B PLUG MICROPHONE IN SECURELY C REPLACE MI...

Страница 13: ...MPLIFIER AND THE AUXIL IARY DEVICES IF IN LEVEL 3 AND THE VEHICLE IS IN PARK THE RED LEVEL INDICATOR ON THE CONTROL HEAD IS BLINKING AT A SLOW RATE A THIS IS NORMAL THIS IS COMMUNICAT ING THAT THE LEVEL 3A OR THE LEVEL 3B LIGHTS ARE IN STANDBY TURNED OFF B LOAD MANAGER HAS SENSED LOW INPUT AND TURNED OFF 3A OR 3B A PUT THE VEHICLE BACK INTO DRIVE B CHECK VEHICLE BATTERY VOLTAGE PA ONLY FUNCTIONS F...

Страница 14: ...14 Siren Wiring Diagram ...

Страница 15: ...rrent 100W 8 Amps 13 6V with 11 ohm load 100 Watt Speaker 12V units 200W 14 Amps 13 6V with 5 5 ohm load 2 100 Watt Speakers 12V units NOTE There is no 58 Watt speaker connection available Standby Current Ignition On 10mA Ignition Off 1mA Cycle Rate Wail 11 cycles minute Yelp 200 cycles minute Voltage Output 66 Vpp Audio Section Audio Response 3 dB down points 500 to 3000 Hz 1000 Hz 0 dB reference...

Страница 16: ...um Each Aux 20 Amp Maximum Total AUX E thru H 10 Amp Maximum Each Aux 30 Amp Maximum Total ArrowStik 8 Output not internally fused Ground Switching 5A Per Output DIM Output 12VDC 1 5A Internally Protected System Weight Amplifier 4 2 lbs 1 9 Kg Control Head 1 1 lbs 0 5 Kg Microphone Boxed Unit 9 5 lbs 4 3 Kg Size Amplifier 9 750 L x 6 832 W x 3 936 H Control Head 6 80 L x 3 30 H x 1 07 D Switch wil...

Страница 17: ...17 Siren Control Head Exploded View ...

Страница 18: ...Assembly T56634 1 8 4 40 X 3 8 Phil Pan HD T06937 2 9 Control HD PCB T11858 1 10 Molded Keypad T15285 1 11 Molded Control Housing T15281 1 12 Moulded Switch Knob T15286 1 13 Part of Amp Box Wiring Label T11863 1 To order a complete Siren Control Head order part number S39284M The Siren Control Head will not function without a Siren Amplifier To order a complete Siren Cable Harness bag order part n...

Страница 19: ...19 Siren Amplifier Exploded View ...

Страница 20: ...Amplifier Cover T15307 1 10 Amplifier Fuse Cover T15310 1 11 8 32 X 250 Phil Pan HD TRS T09751 2 12 Warning Label T09937 1 13 Wiring Label Fuse Map T11861 1 14 Wiring Label Amp Box Top T11863 1 15 6 32 X 2 250 Phil Pan HD MS T15328 3 16 Washer Int Tooth 6 T00150 1 17 6 32 X 1 500 Phil Pan HD MS T01332 1 18 Wiring Label Terminal Side T11863 1 To order a complete Siren Amplifier order part number S3...

Страница 21: ...rness T56631 1 6 CAT5 Cable Min 20 FT T56649 1 7 Input Output Harness T56636 1 8 Amplifier Power Harness T56637 1 9 Aux E H Harness T56638 1 10 USB A Male to A Male Cable T56639 1 11 Mic w Modular Plug T11856 1 To order a complete Siren Amplifier order part number S39285M To order a complete Siren Cable Harness bag order part number T56641 To order a complete Siren Manuals Legends bag order part n...

Страница 22: ...22 NOTES ...

Страница 23: ...23 NOTES ...

Страница 24: ...KES NO OTHER EXPRESS OR IMPLIED WARRANTY INCLUDING WITHOUT LIMITATION WARRANTIES OF FITNESS OR MERCHANTABILITY WITH RESPECT TO THIS PRODUCT PRODUCT RETURNS If a product must be returned for repair or replacement please contact our factory to obtain a Return GoodsAuthorization Number RGA number before you ship the product to Code 3 Inc Write the RGA number clearly on the package near the mailing la...

Отзывы: