background image

Page 3 of 8

Wiring Instructions:

IMPORTANT! This unit is a safety device and it must be connected to its own separate, fused power point to assure its continued operation 

should any other electrical accessory fail.  Do not wire in parallel with any other accessory.

Notes: 

• 

Larger wires and tight connections will provide longer service life for components.  For high current wires it is highly recommended 

that terminal blocks or soldered connections be used with shrink tubing to protect the connections.  Do not use insulation displace

-

ment connectors (e.g., 3M Scotchlock type connectors).

• 

Route wiring using grommets and sealant when passing through compartment walls.  Minimize the number of splices to reduce volt

-

age drop.  High ambient temperatures (e.g., under-hood) will significantly reduce the current carrying capacity of wires, fuses, and 

circuit breakers. All wiring should conform to the minimum wire size and other recommendations of the manufacturer and be pro

-

tected from moving parts and hot surfaces.  Looms, grommets, cable ties, and similar installation hardware should be used to anchor 

and protect all wiring.

• 

Fuses or circuit breakers should be located as close to the power takeoff points as possible and properly sized to protect the wiring 

and devices.

• 

Particular attention should be paid to the location and method of making electrical connections and splices to protect these points 

from corrosion and loss of conductivity.

• 

Ground termination should only be made to substantial chassis components, preferably directly to the vehicle battery.

• 

Circuit breakers are very sensitive to high temperatures and will “false trip” when mounted in hot environments or operated close to 

their capacity.

Caution: 

Disconnect the battery before wiring up the product, to prevent accidental shorting, arcing and/or electrical shock.

Connect the red (power) and black (ground) wires from the Matrix

®

 enabled Thin WingMan to a nominal 12-24 VDC supply, along with a 

customer supplied in-line, 10A slow blow ATC style fuse. 

Please note that the fuse holder selected by the customer must also be rated 

by its manufacturer to meet or exceed the corresponding fuse ampacity.

  See Figure 1 for details.  

The Matrix

®

 enabled Thin WingMan must also connect back to a central node, such as the Serial Interface Box or Z3 Serial Siren, to 

establish serial communication with the larger network. Please note, for CAT5 connections the PRI-1 port must always be utilized first, before 

additional devices can be connected to the SEC-2 port.  See Figure 1 for details.

Figure 1

BLACK

10A

BLACK

10A

RED

RED

Matrix

®

 enabled

Thin Wingman

Matrix

®

 enabled

Thin SuperVisor

CENTRAL NODE

PRI-1

SEC-2

B    Y

Содержание Thin WingMan MATRIX Series

Страница 1: ...ent reach of the operator so that they can operate the system without losing eye contact with the roadway 5 Do not install this product or route any wires in the deployment area of an air bag Equipmen...

Страница 2: ...Brackets These brackets can be bolted to the Outer Panel of the Thin WingMan and modified as needed to mount the unit The Thin WingMan must be hard mounted to the sheet metal of the vehicle to preven...

Страница 3: ...to protect the wiring and devices Particular attention should be paid to the location and method of making electrical connections and splices to protect these points from corrosion and loss of conduct...

Страница 4: ...Arrow Tertiary Right Building Fast Center Out Tertiary Center Out Building Fast Arrow Flash Tertiary Simultaneous Fast Flash Matrix Thin WingMan Flash Pattern Compliance Chart No Description FPM SAE J...

Страница 5: ...low the maximum limit in order to resume normal operation Blown fuse The product may have blown an upstream fuse Check and replace fuse if necessary No Communication Ignition input An ignition wire in...

Страница 6: ...Page 6 of 8 Notes...

Страница 7: ...Page 7 of 8 Notes...

Страница 8: ...SCLAIMED EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW ORAL STATEMENTS OR REPRESENTATIONS ABOUT THE PRODUCT DO NOT CONSTITUTE WARRANTIES Remedies and Limitation of Liability MANUFACTURER S SOLE LI...

Страница 9: ...en reducir su eficacia o convertirse en un proyectil que podr a causar lesiones personales graves o la muerte Consulte el manual del propietario del veh culo para ver el rea de despliegue de la bolsa...

Страница 10: ...al incluye 2 soportes de montaje universales de 90 grados Estos soportes se pueden atornillar al panel exterior de Thin WingMan y modificar seg n sea necesario para montar la unidad Thin Wingman debe...

Страница 11: ...proteger el cableado y los dispositivos Se debe prestar especial atenci n a la ubicaci n y el m todo para realizar conexiones y empalmes el ctricos para proteger estos puntos de la corrosi n y de la p...

Страница 12: ...o con aumento r pido Del centro hacia afuera Terciario central externo con aumento r pido Destello de flecha Terciario de destello r pido simult neo Tabla de cumplimiento del patr n de destello para T...

Страница 13: ...rma temporal para reanudar el funcionamiento normal Fusible fundido Es posible que el producto haya fundido un fusible anterior en el circuito Revise y sustituya el fusible si es necesario Sin comunic...

Страница 14: ...P gina 6 de 8 Notas...

Страница 15: ...P gina 7 de 8 Notas...

Страница 16: ...LA PRESENTE EXCLUIDAS Y NO SE APLICAR N AL PRODUCTO SALVO EN LA MEDIDA EN QUE EST PROHIBIDO POR LA LEY VIGENTE LAS DECLARACIONES O DESCRIPCIONES ORALES SOBRE EL PRODUCTO NO CORRESPONDEN A GARANT AS So...

Отзывы: