5
TROUBLESHOOTINg
Problem
Probable Cause
Remedy
Mini-Bar does not light
a. No power to unit
a. Check wire for loose connection
b. Power input wire reversed
b. Reverse power wires
c. Damaged or shorted cabling
c. Check cables for damage
d. Defective Mini-Bar
d. Contact Service Dept.
Flash Pattern does not change
a. Not pressing Pattern Change
Switch (Mag Mount)
b. Not applying Power to Pattern
Change Wire (Perm Mount)
a. Use Pattern Change Switch
b. Apply Power to Pattern Change
Wire
LED module housings may become hot with extended use. Allow modules to cool completely
before attempting to remove.
WARNING!
Maintenance:
The Shield™ LED Mini-Bar is designed to be weather proof and maintenance free under normal operating con-
ditions. Refer to the guide below for help with troubleshooting. Should the unit be diagnosed as malfunctioning,