background image

920-0655-00 Rev B

Page  5  of  8      

PURSUIT SIREN

TROUBLESHOOTING:

All products are thoroughly tested prior to shipment. However, should you encounter a problem during installation 

or during the life of the product, follow the guide below for troubleshooting and repair information.  If the problem 

cannot be rectified using the solutions given below, additional information may be obtained from the manufacturer 

– contact details are at the end of this document.

PROBLEM

POSSIBLE CAUSE

SOLUTION

Fuse Blows 

¹

Wires short circuit

Check power and ground for short circuits

Faulty unit

If fuse continues to blow after checking the 

wiring replace the product

Unstable operation

HazCAN wiring fault

Check wire colours match the label positions on 

siren unit

¹

 

Note: Always replace the fuse with the same value as shown on the wiring diagram

Содержание Pursuit Siren

Страница 1: ...turer s recommendations may result in property damage serious bodily personal injury and or death to you and those you are seeking to protect SPECIFICATIONS Input Voltage Range 10 30 VDC Current Draw Standby Typ 10 mA Current Draw 200W 18A 12V 9A 24V Speaker Voltage 33Vrms Dimensions H x W x D mm 65 x 121 x 37 Ambient Operating Temperature 30 to 65 C Features 8 configurable I O 3 fixed position in...

Страница 2: ...aximised and the controls are placed within convenient reach of the operator so that s he can operate the system without losing eye contact with the roadway 5 It is the responsibility of the vehicle operator to ensure during use that all features of this product work correctly In use the vehicle operator should ensure the projection of the warning signal is not blocked by vehicle components i e op...

Страница 3: ...and 25A for 200W variants Do not connect this power wire until all other connections have been made to the unit GND Connect to 4 5mm 10 AWG automotive wire to a good chassis ground point or the battery negative terminal using the shortest possible wire length NETWORK B Connect the Blue wire from the HazCAN device s Y Connect the Yellow wire from the HazCAN device s SPKRS 1 Connect Speaker 1 here 2...

Страница 4: ...NA H Power 10 30V Ground Do Not Connect C3 DNA CONNECTOR COLOUR KEY HID 500 25A C1 HID 400 25A PURSUIT LIGHTBAR optional HID 300 White Flash OUTPUT Alley Left OUTPUT Park Light INPUT Sign Light OUTPUT HRT INPUT Primary OUTPUT C1 IO1 IO3 IO5 IO7 IN9 IN11 N C RAD IO2 IO4 IO6 IO8 IN10 N C SYNC RAD 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 Alley Right OUTPUT Secondary OUTPUT Takedown OUTPUT Low Freq Enab...

Страница 5: ... using the solutions given below additional information may be obtained from the manufacturer contact details are at the end of this document PROBLEM POSSIBLE CAUSE SOLUTION Fuse Blows Wires short circuit Check power and ground for short circuits Faulty unit If fuse continues to blow after checking the wiring replace the product Unstable operation HazCAN wiring fault Check wire colours match the l...

Страница 6: ...920 0655 00 Rev B Page 6 of 8 PURSUIT SIREN NOTES ...

Страница 7: ...920 0655 00 Rev B Page 7 of 8 PURSUIT SIREN NOTES ...

Страница 8: ...SS OR IMPLIED THE IMPLIED WARRANTIES FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY EXCLUDED AND SHALL NOT APPLY TO THE PRODUCT BUYER S SOLE AND EXCLUSIVE REMEDY IN CONTRACT TORT OR UNDER ANY OTHER THEORY AGAINST MANUFACTURER REGARDING THE PRODUCT AND ITS USE SHALL BE THE REPLACEMENT OR REPAIR OF THE PRODUCT AS DESCRIBED ABOVE Limitation of Liability IN THE EVENT OF LIABILITY F...

Отзывы: