5. HANGING THE FAN

REMEMBER to turn off the power. Follow the 
steps below to hang your fan properly:

Step 1. Remove the decorative canopy 
bottom cover from the canopy by turning the 
cover counter clockwise. (Fig. 5)

Step 2.  Remove the hanger bracket from the 
canopy by loosening the non-slotted screw 
on the bottom of the hanging bracket a half 
turn from the screw head and removing the 
slotted one, and then turn the canopy counter 
clockwise. (Fig. 5)

Step 3. Pass the 120-volt supply wires 
through the center hole in the ceiling hanger 
bracket as shown in Fig. 6.

Step 4. Secure the hanger bracket to the 
ceiling outlet box with the screws and 
washers provided with your outlet box.

Step 5. Remove the hanger pin, lock pin and 
set screws from the top of the motor 
assembly.

Step 6. Route wires exiting from the top of 
the fan motor through the coupling cover, 
canopy cover, canopy and then through the 
ball/ downrod. (Fig. 7)

Step 7. Align the holes at the bottom of the 
downrod with the holes in the collar on top of 
the motor housing (Fig. 7). Carefully insert 
the hitch pin through the holes in the collar 
and downrod. Be careful not to jam the pin 
against the wiring inside the downrod. Insert 
the locking pin through the hole near the end 
of the hitch pin until it snaps into its locked 
position. 

Step 8. Tighten two set screws on top of the 
fan motor firmly. (Fig. 7)

Step 9. Place the downrod ball into the 
hanger bracket socket. (Fig. 8)

Figure 6

Figure 5

Tab

Mounting screws
(supplied with
electrical box)

UL Listed
electrical
box

Hanger bracket

Hanger bracket

Ceiling 
canopy

Canopy
cover 

Ball/downrod
assembly

Ceiling canopy

Motor wires

Coupling cover

Locking pin

Hanger pin

Tighten screws
firmly

Canopy cover

Figure 8

Figure 7

Registration slot

Содержание CF-A-GR

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS GRAHAM CEILING FAN INSTALLATION AND OPERATION INSTRUCTION FAN RATING AC 120V 60Hz UL LISTED MODEL AC 552RM52B MODEL CF A GR ...

Страница 2: ...cover h Glass shade i 40 Watt candelabra bulbs 3 j Receiver k Transmitter holder 2 mounting screws l 9 Volts battery m Package hardware 1 Mounting hardware screws 2 lock washers 2 star washers 2 wire nuts 3 wood screws 2 washers 2 2 Blade attachment hardware screws 13 fiber washers 13 3 Balance kit Philips screwdriver Blade screwdriver 11 mm wrench Step ladder Wire cutter 1 TOOLS AND MATERIALS REQ...

Страница 3: ...when working around or cleaning the fan 10 Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable for most cleaning 11 After marking electrical connections spliced conductors should be turned upward and pushed carefully up into outlet box The wires should be spread apart with the grounded conductor and the equipment grounding ...

Страница 4: ...he moving weight of the fan at least 50 lbs Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling Fig 3 To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 4...

Страница 5: ...y Step 6 Route wires exiting from the top of the fan motor through the coupling cover canopy cover canopy and then through the ball downrod Fig 7 Step 7 Align the holes at the bottom of the downrod with the holes in the collar on top of the motor housing Fig 7 Carefully insert the hitch pin through the holes in the collar and downrod Be careful not to jam the pin against the wiring inside the down...

Страница 6: ...eiver to House Supply Wires Electrical Connections Connect the black hot wire from the ceiling to the black wire marked AC in L from the receiver Connect the white neutral wire from the ceiling to the white wire marked AC in N from the Receiver Secure the wire connections with the plastic wire nuts provided Step 4 Fig 11 If your outlet box has a ground wire green or bare copper connect it to the f...

Страница 7: ...ws as necessary until the canopy and canopy cover are snug Warning Make sure tab at bottom of hanger bracket is properly seated in groove of hanger ball before attaching canopy to bracket Failure to properly seat tab in groove could cause damage to electrical wiring Outlet box Hanger bracket Canopy Canopy cover Screws 8 ATTACHING THE FAN BLADES Step 1 Insert the blade through the blade slot in the...

Страница 8: ...ht kit until it locks in place at the narrow section of the key holes secure the light plate by tightening the 2 screws previously loosened and the one previously removed Step 3 Proceed the wire connections Connect the white wire connectors from the light kit and fan Follow the same procedure with the black wire connectors Step 4 Carefully push all wires back into the concave inside the light plat...

Страница 9: ...se at fuse box Turning power off using the fan switch is not sufficient to prevent electric shock Step 1 Install 3 x 40W candelabra bulbs included Fig 16 Step 2 Raise glass shade up against the light plate and secure it by turning clockwise until snug Do not over tighten Step 3 Restore power and your light kit is ready for operation 8 Light plate Glass shade Bulbs ...

Страница 10: ...he button to set the desired brightness The light key has an auto resume it will stay at the same brightness as the last time it was turned off The REV button is used to set the fan forward or reverse Speed settings for warm or cool weather depend on factors such as the room size Ceiling height number of fans and so on NOTE To operate the reverse function on this fan press the reverse button while...

Страница 11: ...to remove fan from ceiling 2 Clean your fan periodically to help maintain its new appearance over the years Use only a soft brush or lint free cloth to avoid scratching the finish The plating is sealed with a lacquer to minimize discoloration or tarnishing Do not use water when cleaning This could damage the motor or the wood or possibly cause an electrical shock 3 You can apply a light coat of fu...

Страница 12: ... touch the ceiling 1 Do not connect the fan with wall mounted variable speed control s 2 Make sure the dip switches are set correctly 1 This unit is equipped with a wattage limiting device Lamping in excess of 190 watts will disable your ceiling fan s light kit To reset your light kit you must turn the power off and re lamp keeping the wattage under 190 watts Restore power to your ceiling fan and ...

Отзывы: