SAFETY & CLEARANCE
NOTE:
In all cases, the
Chimenea
must:
•
be installed onto load bearing material ONLY;
•
be installed in low traffic areas to avoid injury to persons moving around and to avoid the
Chimenea
being bumped which may cause fuel to spill.
•
have all gas connections or pipelines near
Chimenea
installation must be disconnected and
made safe by an appropriately qualified professional prior to installation;
•
be installed onto a load bearing, level and secure position before filling, lighting and
operating;
•
be installed in a position that limits relocation requirements to eliminate the risk of accidents
caused by fuel spillage. This
Chimenea
is designed to be relocated but
Combustion Chamber
must be removed from the
Main Body
before relocating to avoid fuel spillage;
•
NOT be installed directly beside or near wallpaper, laminate, veneer or any surface that has
not been fire rated and considered combustible.
•
A minimum of 102 cm radius to any combustible material.
•
NOT be within the reach of any objects that are not fixed in position and can be moved by
the wind or bumped over easily i.e. curtains, blankets, newspapers etc.
KEEP HANDY A CLASS ABE FIRE EXTINGUISHER!
USE CORRECT FUEL
–
BIOETHANOL
FUEL IS TO BE STORED IN A FIRE SAFE AREA AND IS TO BE DONE IN ACCORDANCE WITH NATIONAL AND/OR
REGIONAL REGULATIONS.
WARNING:
In a house of typical construction, that is, one that is not of unusually tight
construction due to heavy insulation and tight seals against air infiltration, an
adequate supply of air for combustion and ventilation is provided through
infiltration. However, if the unvented decorative appliance is used in a small
room where less than 200 cubic feet (5,7 m
³
) of air space is provided for each
1000 Btu per hour of unvented decorative appliance rating (considering the
maximum burner adjustment), the door(s) to adjacent room(s) should be kept
open or a window to the outside should be opened at least 1 inch (2,4 cm) to
guard against potential build-up of indoor air pollution. Do not use the
unvented decorative appliance in a bathroom, a room(s) where sleeping
accommodation is provided or any other small room(s).
MINIMUM ROOM SIZE 60m3