Gauge Mode Alarm
The dive computer will sound its five-chirp alarm just prior to entering Gauge
Mode. It will re-issue this five-chirp alarm if the CTU is powered up within 24
hours after entering Gauge Mode.
The computer will enter the Gauge Mode if:
•
More than five minutes has elapsed with the depth less than the
ceiling, or
•
A ceiling depth of greater than 90 feet is required, or
•
The maximum functional operating depth of 327 feet is exceeded.
Oxygen Tolerance Units (OTU) Dose Warning
Should you reach 75 percent of the allowable Mission OTU dosage, your dive
computer will issue a one-time audible warning consisting of short, double-beeps
that sound for five seconds. The WARNING legend will appear and flash and the
TEMPerature digits
will be replaced with the current calculated OTU toxicity
percentage. This visual warning will continue until the calculated toxicity
percentage is less than 75 percent.
Central Nervous System (CNS) Oxygen Toxicity Warning
Should you reach 75 percent of the associated maximum limit, your dive
computer will issue a one-time audible warning consisting of short, double-beeps
that sound for five seconds. The WARNING legend will appear and flash and the
TEMPerature digits will be replaced with the current calculated CNS Oxygen
Toxicity percentage. This visual warning will continue until the calculated toxicity
percentage is less than 75 percent.
NOTE: If both CNS and OTU levels are greater than 75 percent, the more
critical of the two percentages will be displayed.
Maximum PO
2
Alarm
This alarm, settable via the Analyst interface, allows you to set a desired
maximum level from 0.5 to 1.6 ATA. Should you exceed this setting, the TU will
issue the double chirp toxicity alarm once per minute. The factory setting for this
alarm is 1.6 ATA.
Minimum PO
2
Alarm
This alarm, settable via the Analyst interface, allows you to set a desired
minimum level from 0.2 to .40 ATA. Should you exceed this setting, the TU will
issue the double chirp alarm once per minute. The factory setting for this alarm
is .2 ATA.