<<16>>
•
For continuous operation, do not exceed the
rated out-put power of generator.
•
Do not make parallel connection with other
generators.
•
Do not connect an extension to the exhaust pipe.
•
When an extension cable is required, be sure to
use a tough rubber sheathed flexible cable
(according to IEC245 or equivalent standards).
The maxmim length of the
2
extension cable: 60m for cable of 1.5mm ;
2
100m for cable of 2.5mm .
•
Keep away from other electric cables or wires.
WARNING
NOTE
•
The
DC
receptacle can be used while the
AC
power is in use. If both are used at the same
time, be sure not to exceed the total power for
AC
and
•
(AC:2.6kVA, DC:5A)
•
Most of motor appliances
require more than
their rated wattage, when starting.
6.1) DC Application
The
DC receptacle, 15-30V
under
no
load
condition,
may be used for charging 12V battery only.
NOTE
In
DC
operation, turn
the
ECON
SW
to
the
“OFF” ( ) position.
6.1.1)
Disconnect the
vehicle
battery
ground
cable
from
the
negative
battery
terminals.
6.1.2)
Connect the DC terminals to battery
terminals
with the
charging cable
CAUTION
Connect
red
lead
to
positive
battery
terminal
and
black
lead
to
negative
battery terminal.
6.1.3) Turn
ECON
SW
to “OFF” ( )
position
and
then
start
engine
Содержание IG32ESI
Страница 1: ...4 Stroke Engine INVERTER GENERATOR USER MANUAL Model IG32ESI...
Страница 2: ......
Страница 4: ......
Страница 7: ...05 SAFETY LABEL...
Страница 8: ...06 2 SAFETY LABEL LOCATIONS...
Страница 12: ...10 Oil Capacity 0 6L...
Страница 40: ...Cobra Garden Machinery Henton and Chattell Ltd London Road Nottingham NG2 3HW UK...