11

Ground Wiring

There is a screw on the rear panel labeled Chassis
Ground. This is to connect the chassis of the
inverter to ground. The ground terminal in the AC
outlet on the right side panel of the inverter is
connected to the chassis.

The Chassis Ground screw must be connected to
a grounding point, which will vary depending on
where the unit is installed. Use a #8 AWG copper
wire (preferably with green/yellow insulation) to
connect the chassis ground screw to the ground-
ing point.

• In a vehicle, connect the Chassis Ground to the

chassis of the vehicle.

• In a boat, connect to the boat grounding 

system.

• In a fixed location, connect the Chassis Ground

screw to earth ground by connecting to a
ground rod (a metal rod pounded  into the
earth) or other proper service entrance
ground.

Ground
Wiring

Warning:

Do not operate the

inverter without connecting it

to ground. Electrical shock

hazard may result.

Ground Wiring

10

If the cable has too much voltage drop, the
inverter may shut down when drawing higher
currents because voltage at the inverter may
drop below 10 volts. If you must use longer
cables choose thicker cables, such as #2 AWG,
and trim the ends of the cable to fit the terminals.

Strip back the insulation about 1/2 inch (1.25cm)
on the end of the cable that connects to the
inverter, exposing the bare cooper conductor.
The other end of the cable that connects to bat-
tery must be terminated with a battery terminal
that clamps to the post on the battery.

CAUTION:

Electrical installa-

tions must meet local and

national wiring codes, and

should be performed by a

qualified electrician.

CAUTION:

Do not connect the

inverter and another AC source

(such as a generator or utility

power) to the AC wiring at the

same time. The inverter will be

damaged if its output is con-

nected to AC voltage from

another source. Damage can

even occur if the inverter is

switched Off.

CAUTION:

Do not connect the

inverter to an AC branch circuit

that has high-power  con-

sumption loads. It will not

operate electric heaters, air

conditioners, stoves, and other

electrical appliances that con-

sume more than 1000 watts.

Cables 

Содержание High Gear HG-PI1000

Страница 1: ...Operating Instructions for Your High Gear by Cobra 1000 Watt Power Inverter Nothing comes close to a CobraTM HG PI1000...

Страница 2: ...our automobile or other low voltage power supplies and CONVERT it to standard 115 Volt AC Alternating Current power like the current you have in your home This conversion process thereby allows you to...

Страница 3: ...to the manual you still need help call Cobra Customer Service at 773 889 3087 Cobra Customer Service Live operators are avail able M F 8 00 am 6 00 pm CST at 773 889 3087 Automated Technical Assistanc...

Страница 4: ...ables 9 Ground Wiring 11 DC Wiring 12 Controls and Indicators 14 Operating Limits 15 Troubleshooting Guide 16 Maintenance 17 Specifications 18 Warranty 19 If You Think You Need Service Back Cover Feat...

Страница 5: ...at it produces a low voltage AC or DC output less that 30 volts the inverter will have no problem powering it safely Caution Rechargeable Appliances 2 To make the most of this inverter it must be inst...

Страница 6: ...tallation Be sure to have the fol lowing on hand A 12 volt DC power source such as a vehicle battery A set of cables to connect the power source to the inverter A test load that can be plugged into th...

Страница 7: ...nds of the cables into the terminals and tighten the screws to clamp the wires safely 3 Connect the cable from the negative black terminal of inverter to the negative terminal of the power source Make...

Страница 8: ...an electric shock WARNING 115Volt AC power is potentially lethal Do not work on AC wiring when it is connect ed to the inverter even if it is switched off unless the DC power source is physically dis...

Страница 9: ...drop the inverter may shut down when drawing higher currents because voltage at the inverter may drop below 10 volts If you must use longer cables choose thicker cables such as 2 AWG and trim the ends...

Страница 10: ...ear panel of the inverter The red terminal is positive and the black terminal is negative Insert the bare ends of the cables into the terminals and tighten the screws to clamp the wires securely 3 Con...

Страница 11: ...ter against excessive input voltage Although the inverter has protection against over voltage it may still be damaged if the input voltage were to exceeds 16 volts Operating Limits 14 ON OFF Switch Tu...

Страница 12: ...ng Guide Troubleshooting Guide 17 Problem Symptom Possible Causes Solution Low battery alarm on Poor DC wiring Use proper cable all the time poor battery make solid voltage indicator condition connect...

Страница 13: ...To extend the life of the fan it will stop when there is no load The speed of the fan increases as the load increases The unit is completely insulat ed in input and output for added safety Equipment...

Страница 14: ...y Exclusions This limited warranty does not apply 1 to any product damaged by accident 2 in the event of misuse or abuse of the product or as a result of unauthorized alter ations or repairs 3 if the...

Страница 15: ...de some form of proof of purchase such as a mechanical reproduction or carbon or a sales receipt If you send the original receipt it cannot be returned 2 Send the entire product 3 Enclose a descriptio...

Отзывы: