Cobra High Gear HG-PI1000 Скачать руководство пользователя страница 6

5

Testing

Test Load Power

Minimum Cable Size

100 w

#16 AWG copper

250 w

#12 AWG copper

500 w

# 8  AWG copper

The end of the cable that connects to the invert-
er must have its insulation stripped off for about
1/2 inch (1.25cm) back from the end, exposing
the bare copper.

The other end of the cable, which connects to

the power source, must be terminated with a lug
or other connector that provides a secure, low
resistance connection.

For example, if the power source is a battery, the
cable must be terminated with a battery terminal
that clamps to the post on the battery.

Connection

1. Turn the ON/OFF switch on the inverter to 

the OFF position.
If the power source is a DC power supply,
switch it off as well.

Testing/Connection

4

Quick Checkout

This section provides you with basic information
about the inverter and how to check its perfor-
mance before installation. Be sure to have the fol-
lowing on hand:

A 12 volt DC power source (such as a vehicle battery)

A set of cables to connect the power source to the inverter

A test load that can be plugged into the AC receptacle 
on the inverter

Power Source

The power source must provide between 11 and 15
volts DC and be able to supply enough current to
run the test load. As a rough guide, divide the
wattage of the test load by 10 to get the current (in
amperes) the power source must deliver.

Cables 

(included)

The cables must be as short and thick as possible
in order to reduce the voltage drop between the
power source and the inverter when it is drawing
current from the power source.

If the cable suffers an excessive voltage drop, the
inverter may shut down when drawing higher cur-
rents because the voltage at the inverter dropped
below 10 volts.

#4 AWG stranded copper cable is recommended. It
should be no longer than 1.5 meters (4 ft.). For
short term testing at a low power level, the 
following is recommended:

Quick
Checkout

Quick Checkout

Testing

Connection

Содержание High Gear HG-PI1000

Страница 1: ...Operating Instructions for Your High Gear by Cobra 1000 Watt Power Inverter Nothing comes close to a CobraTM HG PI1000...

Страница 2: ...our automobile or other low voltage power supplies and CONVERT it to standard 115 Volt AC Alternating Current power like the current you have in your home This conversion process thereby allows you to...

Страница 3: ...to the manual you still need help call Cobra Customer Service at 773 889 3087 Cobra Customer Service Live operators are avail able M F 8 00 am 6 00 pm CST at 773 889 3087 Automated Technical Assistanc...

Страница 4: ...ables 9 Ground Wiring 11 DC Wiring 12 Controls and Indicators 14 Operating Limits 15 Troubleshooting Guide 16 Maintenance 17 Specifications 18 Warranty 19 If You Think You Need Service Back Cover Feat...

Страница 5: ...at it produces a low voltage AC or DC output less that 30 volts the inverter will have no problem powering it safely Caution Rechargeable Appliances 2 To make the most of this inverter it must be inst...

Страница 6: ...tallation Be sure to have the fol lowing on hand A 12 volt DC power source such as a vehicle battery A set of cables to connect the power source to the inverter A test load that can be plugged into th...

Страница 7: ...nds of the cables into the terminals and tighten the screws to clamp the wires safely 3 Connect the cable from the negative black terminal of inverter to the negative terminal of the power source Make...

Страница 8: ...an electric shock WARNING 115Volt AC power is potentially lethal Do not work on AC wiring when it is connect ed to the inverter even if it is switched off unless the DC power source is physically dis...

Страница 9: ...drop the inverter may shut down when drawing higher currents because voltage at the inverter may drop below 10 volts If you must use longer cables choose thicker cables such as 2 AWG and trim the ends...

Страница 10: ...ear panel of the inverter The red terminal is positive and the black terminal is negative Insert the bare ends of the cables into the terminals and tighten the screws to clamp the wires securely 3 Con...

Страница 11: ...ter against excessive input voltage Although the inverter has protection against over voltage it may still be damaged if the input voltage were to exceeds 16 volts Operating Limits 14 ON OFF Switch Tu...

Страница 12: ...ng Guide Troubleshooting Guide 17 Problem Symptom Possible Causes Solution Low battery alarm on Poor DC wiring Use proper cable all the time poor battery make solid voltage indicator condition connect...

Страница 13: ...To extend the life of the fan it will stop when there is no load The speed of the fan increases as the load increases The unit is completely insulat ed in input and output for added safety Equipment...

Страница 14: ...y Exclusions This limited warranty does not apply 1 to any product damaged by accident 2 in the event of misuse or abuse of the product or as a result of unauthorized alter ations or repairs 3 if the...

Страница 15: ...de some form of proof of purchase such as a mechanical reproduction or carbon or a sales receipt If you send the original receipt it cannot be returned 2 Send the entire product 3 Enclose a descriptio...

Отзывы: