Mounting

Installation Requirements 

The inverter must be installed in an area that meets all  

of the following requirements:
A.  Dry  

Do not place in an area where water can drip  

or splash on the inverter.

B.  Cool 

Ambient air temperature should be between 30°F  

and 105°F (0°C and 40°C). The cooler the better.

C.  Ventilate 

Allow at least one inch (three cm) of clearance around 

the inverter for proper airflow. Make sure that ventilation 

openings on the ends of the unit are not obstructed.

D. Safe 

Do not install the inverter in the same compartment  

as a battery or in any compartment that contains  

flammable liquids such as gasoline.

E.  Close to Battery 

Install unit as close to battery as possible (without 

being in the same compartment) to minimize the  

length of cable required to connect the inverter to  

the battery. It is better and cheaper to run longer  

AC wires than longer DC wires (cables).

CAUTION To avoid fire, do not cover or  

obstruct ventilation openings. Do not install inverter 

in a zero-clearance compartment. Overheating may 

result.
CAUTION The inverter must only be connected to 

batteries with a nominal output voltage of 12 volts.  

It will not work with a 6 volt battery, and will be 

damaged if it is connected to a 16 volt battery.

WARNING This unit contains components  

which can produce arcs or sparks. To prevent  

fire or explosion, do not install in compartments 

containing a battery or flammable materials,  

or in a location which requires ignition  

protected equipment.
WARNING This unit is suitable for installation  

in negative ground applications only. Do not 

attempt to install to a positive ground application.

Mounting 

To mount your inverter:
1.
  Place the inverter on a flat surface with the  

mounting bracket against the mounting surface.

2.  Mount to secure surface using mounting hardware  

that is corrosion resistant (not included).

The inverter can be mounted horizontally or vertically. 

If mounted vertically, neither end of the unit should be at 

the top (to avoid foreign material from falling or settling 

into the unit).

Intro

Operation

Customer

Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Installation

Installation Requirements

Intro

Operation

Customer

Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Installation

Mounting Hardware

Mounting Brackets

CPI2590_MANL.indd   6-7

12/5/14   2:11 PM

Содержание CPI2590

Страница 1: ...owner s manual If you require further assistance after reading this manual Cobra Electronics offers the following customer assistance services For Assistance in the U S A Automated Help Desk English o...

Страница 2: ...Notes Notice Main Icons Secondary Icons Caution Warning Installation Contents Introduction Our Thanks to You A1 Customer Assistance A1 Product Features A2 Important Safety Information 1 Quick Evaluat...

Страница 3: ...g and using it Special attention must be paid to the CAUTION and WARNING statements in the manual CAUTION Statements specify conditions which could cause damage to the unit or other equipment WARNING...

Страница 4: ...nd night lights that can be plugged directly into an AC receptacle to recharge 2 Certain battery chargers for battery packs used in hand power tools These chargers have a WARNING label stating that da...

Страница 5: ...es for a full 2500 Watt load 3 A test load that can be plugged into the AC receptacle on the inverter for short term testing at a low power level The following cables are recommended for testing low p...

Страница 6: ...ce compartment Overheating may result CAUTION The inverter must only be connected to batteries with a nominal output voltage of 12 volts It will not work with a 6 volt battery and will be damaged if i...

Страница 7: ...n on the inverter to the off position If the power source is a DC power supply switch it off as well 2 Connect cables to the Power Input Terminals on input end of the inverter The red terminal is posi...

Страница 8: ...m the Positive Red Terminal of the inverter to the Positive Terminal of the power source the battery s main fuse or the battery selector switch if you are using one Make a secure connection NOTE Pleas...

Страница 9: ...dary Icons Caution Warning Installation Installation Intro Operation Customer Assistance Warranty Notes Notice Main Icons Secondary Icons Caution Warning Installation Installation Laptop 100 watts x 2...

Страница 10: ...the unit s power status and alarms for conditions that could cause it to shut down Power on The Voltage Input and Power Output indicators automatically toggle between input and output values at three...

Страница 11: ...wn to indicate Over Voltage Protection and an alarm will sound To restore normal operation return the DC input voltage to less than 15V The inverter will automatically return to normal operation High...

Страница 12: ...the input voltage exceeds 12V 0 3V The inverter will also shut down if the input voltage exceeds 15 5V 0 5V This protects the inverter against excessive input voltage Although the inverter has protect...

Страница 13: ...ivery to the Cobra Factory Service department accompanied by proof of the date of first consumer purchase such as a duplicated copy of a sales receipt You must pay any initial shipping charges require...

Страница 14: ...ransit to Cobra Factory Service Cobra Electronics Corporation 6500 West Cortland Street Chicago Illinois 60707 USA 6 If the power inverter is in warranty upon receipt of your power inverter it will ei...

Страница 15: ...24 Notes...

Отзывы: