REMOTE DISPLAY MESSAGING
Standby Mode
When you plug in the
Remote On/Off Controller with Fast Charge USB
and press the power button to
ON, the display will show AC Output (Watts being used) and the DC Input (Battery Volts). The images
below show the messaging on the LCD display when the remote is turned ON or OFF.
Inverter ON Inverter OFF
NOTE:
Backlight turns off after 5 seconds from pressing the POWER
…………………………………………………………………………………………………………………………………………………………………..
Fault Messaging
Your inverter and remote are equipped to sound an alarm to alert you when power requirements or
battery voltage is not in range. This is considered a "fault". When this happens, both the inverter and
remote alarms will sound, and if the fault is not addressed, the inverter will shut down and the remote
will display a fault message. Below is a list of "faults" and the messaging that will appear on the LCD
display when these faults occur.
DC Input Low Voltage Alarm (Default Setting)
DC Input Low Voltage Cutoff (Default Setting)
The alarm will sound when the battery is at 11.5V
The alarm will sound and the inverter will shut down
when the battery is at 10.5V.
……………………………………………………………………………………………………………………………………………………..
DC Input Low Voltage Alarm (Alternate Setting) DC Input Low Voltage Cutoff (Alternate Setting)
The alarm will sound when the battery is at 10.5V. The alarm will sound and the inverter will shut
down when the battery is at 9.5V.
Содержание CPI1500W
Страница 1: ...1 P a g e 2020 Cobra Electronics Corporation Version A...
Страница 4: ...4 P a g e CONTROLS AND CONNECTIONS PRO 1500W Features...
Страница 6: ...6 P a g e PRO 2500W and 3000W Features...
Страница 15: ...15 P a g e PRO 1500W INSTALLATION...
Страница 18: ...18 P a g e PRO 2500W AND 3000W INSTALLATION...
Страница 29: ...29 P a g e...