Cobra CPI1500W Скачать руководство пользователя страница 22

22 | 

P a g e

 

 

OPERATING INDICATORS 

Indicators on the power inverter show the unit’s power status and alarms for conditions that could cause it to 

shut down. 

 

 

 

 

 

Power on – 

The Voltage Input and Power Output indicators automatically toggle between 

input and output values at three-second intervals. The three LEDs indicate the mode the 

meter is in and the three digits indicate the voltage or power value. 

 

Current Overload Protection – 

If the inverter is overloaded, it will shut down to protect 

itself. The meter will flash as shown to indicate Overload Protect. 

 

To restore normal operation, disconnect the excessive load and turn the unit 

Off 

and 

On 

again using the 

Power Button

Short Circuit Protection – 

If the AC output of the inverter is short-circuited for one second 

or more, it will shut down to protect itself. The meter will flash as shown to indicate Short 

Circuit Protect and an alarm will sound. To restore normal operation, disconnect the short 

circuit and turn the unit 

Off 

and 

On 

again using the 

Power Button

 

Low Voltage Protection - 

If the DC input voltage drops below the alarm threshold of 11.3V 

the meter will flash as shown to indicate Low Voltage Protection, but the unit will continue 

to operate. If the input voltage drops to 10.0V or less, the inverter will shut down to 

protect itself, the meter will continue to flash as shown, and an alarm will sound. To 

restore normal operation, return the DC input voltage to at least 12V. The inverter will 

automatically return to normal operation. 

High Voltage Protection - 

If the DC input voltage rises above 15.0V, the inverter will shut 

down to protect itself, the meter will flash as shown to indicate Over Voltage Protection, 

and an alarm will sound. To restore normal operation, return the DC input voltage to less 

than 15V. The inverter will automatically return to normal operation. 

Over Temperature Protection – 

If the internal inverter temperature rises above the alarm 

threshold, the meter will flash as shown, an alarm will sound to indicate Over Temperature 

Protect, and the unit will continue to operate. If the internal temperature rises to 40ºC 

(104ºF), the inverter will shut down to protect itself, the meter will flash as shown and the 

alarm will continue to sound. 

 

GFI Tripped Indicator – 

if the power inverter detects a ground fault then the AC output is 

disabled, an alarm will sound then you will get the following display. To restore to normal 

inverter operation, first unplug faulty appliance. Then, manually reset the power inverter 

by turning it OFF then ON.  

 

NOTE: 

Internal inverter temperature can rise due to being operated in a high heat environment or due to the 

fan or vents being blocked during operation (even in relatively cool outside air). To restore normal operation, 

turn the unit 

Off 

and allow it to cool. The inverter will automatically return to normal operation after it has 

cooled. 

Содержание CPI1500W

Страница 1: ...1 P a g e 2020 Cobra Electronics Corporation Version A...

Страница 2: ...ALLATION REQUIREMENTS 12 CONNECTING TO A VEHICLE BATTERY 12 PRO 1500W INSTALLATION INSTRUCTIONS 13 PRO 2500W 3000W INSTALLATION INSTRUCTIONS 16 TURNING YOUR INVERTER ON AND OFF 19 CHANGING THE LOW VOL...

Страница 3: ...where else with a 12 Volt battery PRODUCT SERVICE AND SUPPORT For any questions about operating or installing this new Cobra product PLEASE CONTACT COBRA FIRST do not return this product to the retail...

Страница 4: ...4 P a g e CONTROLS AND CONNECTIONS PRO 1500W Features...

Страница 5: ...LED Output Power Indicator When active output power is in Watts W G 4 GFCI Protected AC Outlets H Digital Display showing Battery Voltage V Power in kilowatts kW Power in Watts W and Error Codes I USB...

Страница 6: ...6 P a g e PRO 2500W and 3000W Features...

Страница 7: ...hen active output power is in Watts W G 4 GFCI Protected AC Outlets H Digital Display showing Battery Voltage V Power in kilowatts kW Power in Watts W and Error Codes I USB C Fast Charge port 5V 9V 15...

Страница 8: ...the ventilation openings 5 Do not install the inverter in zero clearance compartment 6 Do not allow water or liquids in contact with the power inverter 7 Do not use appliances with damaged or wet cord...

Страница 9: ...safely Cobra PRO Output Waveform Some very sensitive electronic equipment may not operate satisfactory on the output waveform referred to as modified sine wave which this inverter is designed It is a...

Страница 10: ...the power inverter you must determine the battery s reserve capacity how long the battery can deliver a specific amount of current in automotive batteries usually 25 ampere or ampere hour capacity a m...

Страница 11: ...he battery bank MOUNTING THE INVERTER Do not mount the power inverter under the hood of any vehicle Choose a cool dry and well ventilated area inside the vehicle as close to the battery as possible Pl...

Страница 12: ...ipment WARNING This unit is suitable for installation in negative ground applications only Do not attempt to install to a positive ground application CONNECTING TO A VEHICLE BATTERY Power wire and wir...

Страница 13: ...verter to your battery use a wire gauge that is appropriate for your installation 4 For safety reasons install a properly rated fuse not included on the red cable as close to the positive red battery...

Страница 14: ...voltage drop and may cause over heated wires and melted insulation CAUTION Reverse polarity connections positive to negative will blow internal fuses in the inverter and may permanently damage the un...

Страница 15: ...15 P a g e PRO 1500W INSTALLATION...

Страница 16: ...er to the battery If a longer cable is required to connect your inverter to your battery use a wire gauge that is appropriate for your installation 4 For safety reasons install a properly rated fuse n...

Страница 17: ...y cause over heated wires and melted insulation CAUTION Reverse polarity connections positive to negative will blow internal fuses in the inverter and may permanently damage the unit Such damage is no...

Страница 18: ...18 P a g e PRO 2500W AND 3000W INSTALLATION...

Страница 19: ...IC OPERATION 1 Press the POWER button to turn on your inverter 2 When powered on the Input Voltage LED is green PRO 3000W POWER INVERTER BASIC OPERATION 1 Connect the Remote On Off Controller in the R...

Страница 20: ...ttery at this rate depending on the age of the battery CHANGING THE LOW VOLTAGE ALARM SETTING Cobra Pro Power Inverters are equipped with 2 settings to accommodate battery run times for both professio...

Страница 21: ...r compatibility with the Cobra Remote On Off Controller with Fast Charge USB to allow you to conveniently turn the inverter ON and OFF from anywhere inside your vehicle as well fast charge your device...

Страница 22: ...ash as shown and an alarm will sound To restore normal operation return the DC input voltage to at least 12V The inverter will automatically return to normal operation High Voltage Protection If the D...

Страница 23: ...lts Optimum performance will occur when the voltage is between 12 volts and 14 volts If the voltage drops below 11 5V 0 3V an audible low battery warning will sound Your inverter comes equipped with 2...

Страница 24: ...n la on openings in the inverter are not obstructed Reduce ambient temperature No output voltage Protect indicator lighted High input voltage Make sure the inverter is connected to 12V ba ery Check re...

Страница 25: ...11 5V DC Default 10 5V Selectable Option Low Battery Shutdown 10 5V DC Default 9 5V DC Selectable Option 10 5V DC Default 9 5V DC Selectable Option 10 5V DC Default 9 5V DC Selectable Option USB A Out...

Страница 26: ...t on Cobra for Power Where You Need It Works with Cobra Power Inverters CPI400PSW CPI500W CPI1500W CPI2500W and CPI3000W Cobra Remote On Off Controller with Fast Charge USB Model CPIALCDG1 Cobra and t...

Страница 27: ...ast Charge USB C D Fast Charge USB A E Flush Mounts F Clip Mount for Clip Mounting Option G Keyhole Mount H RJ 45 Remote Control Cable Jack I RJ 45 Remote Control Cable J Clip Mont K M3 5 Screws Fast...

Страница 28: ...hether you own a standard vehicle RV Professional Truck or Camper Cobra gives you 4 Mounting options to remotely turn your inverter on and off as well as charge your devices from anywhere in your vehi...

Страница 29: ...29 P a g e...

Страница 30: ...range This is considered a fault When this happens both the inverter and remote alarms will sound and if the fault is not addressed the inverter will shut down and the remote will display a fault mess...

Страница 31: ...ut down when the AC output is shorted AC Output Overload Inverter Over Temperature The alarm will sound and the inverter will shut down The alarm will sound and the inverter will AC output exceeds the...