Continuous output power (1 hour)  . . . . . . . . . . . . 400w
Surge rating (0.1 second)  . . . . . . . . . . . . . . . . . . . 800w
Peak efficiency (12V – 1⁄2 load) . . . . . . . . . . . . . . > 88%
Efficiency (full load, 12V)  . . . . . . . . . . . . . . . . . . . > 83%
No load current draw . . . . . . . . . . . . . . . . < 0.5A (12.6V)
Output waveform (resistive load)  . . . Modified sine wave
Output frequency  . . . . . . . . . . . . . . . . . . . . 58HZ – 62HZ
Output voltage  . . . . . . . . . . . . . . . . . . . . . . 109V – 120V
Input voltage . . . . . . . . . . . . . . . . . . 10.4VDC – 14.4VDC
Alarm voltage (unload)  . . . . . . . . . . . . . . .10.2V – 10.8V
Shutdown voltage (unload)  . . . . . . . . . . . . . 9.2V – 9.8V
Operating temperature range  . . . . . . . . . . . . 0°C – 40°C 

(32°F – 104°F)

Storage temperature range  . . . . . . . . . . . . -40°C – 85°C 

(-40°F – 185°F)

Protection  . . . . . . . . . .Overload, short-circuit, overtemp,

reverse polarity, under/over voltage 

Notes

All protection is automatically recovered.

To protect the battery, if the unit needs to be restarted
after low voltage protection, the voltage of DC input
should be above 12V. 

To extend the life of the fan, it will stop when there is no
load. The speed of the fan increases as the load increases.

The unit is completely insulated in input and output for
added safety.

Problem/Symptom

Low output voltage 

No output voltage 

No output voltage
after prolonged use

No output voltage,
“Protect” indicator
lighted

No output voltage

No power to
inverter 

Low battery alarm
on all the time

Possible Causes

Overload 

Low input voltage

Thermal 
shutdown

High input 
voltage

Short circuit

Blown fuse

Poor DC wiring

Poor battery
condition

Solution

Reduce the load.

Recharge battery.
Check connections
and cable.

Allow inverter 
to cool off.

Reduce load,
continuous
operation input
current required.

Improve ventilation;
Make sure ventilation
openings in the
inverter are not
obstructed.

Reduce ambient
temperature.

Make sure 
the inverter is
connected to 
12V battery.

Check regulation 
of charging system.

Check load for
proper operation.

Replace fuse.

Check
connections.

Make sure battery 
is fully charged.

Troubleshooting Guide

Содержание CPI 400

Страница 1: ... Assistance Should you encounter any problems with this product or not understand its many features please refer to this owner s manual If you require further assistance after reading this manual Cobra Electronics offers the following customer assistance services For Assistance In the U S A Automated Help Desk English only 24 hours a day 7 days a week 773 889 3087 phone Customer Assistance Operato...

Страница 2: ...rmation 1 Quick Evaluation Before Installation 4 Installation Installation Requirements 6 Mounting 7 Connecting Cables 8 Power Consumption 10 Operation Turning Your Inverter On or Off 11 Power and Protection Indicators 12 Operating Limits 13 Troubleshooting Guide 14 Specifications 15 Warranty Warranty 16 Customer Assistance Maintenance 17 Product Service 17 Accessories and Order Form 18 Protection...

Страница 3: ...o the unit or other equipment WARNING Statements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compartment where gas and battery fumes are present 2 Do not operate the inverter if it has been dropped or damaged in any way 3 Do not open the inverter it contains no user serviceable parts Attempting to serv...

Страница 4: ...ashlights razors and night lights that can be plugged directly into an AC receptacle to recharge 2 Certain battery chargers for battery packs used in hand power tools These chargers have a WARNING label stating that dangerous voltages are present at the battery terminals This problem does not occur with the vast majority of battery operated equipment Most use a separate charger or transformer that...

Страница 5: ...er cable for loads higher than 150 watts When connecting loads larger than 150 watts please connect the inverter directly to the battery A test load that can be plugged into the AC receptacle on the inverter for short term testing at a low power level To Check Your Inverter s Performance Before Installation 1 Turn the inverter Off see page 11 for details If the power source is a DC power supply sw...

Страница 6: ...mpartment Overheating may result CAUTION The inverter must only be connected to batteries with a nominal output voltage of 12 volts It will not work with a 6 volt battery and will be damaged if it is connected to a 16 volt battery WARNING This unit contains components which can produce arcs or sparks To prevent fire or explosion do not install in compartments containing a battery or flammable mate...

Страница 7: ... to your vehicle s cigarette lighter socket NOTE If the inverter is to be used at levels above 150 watts for extended periods of time a direct connection to the battery is recommended Do not use the cigarette cord for loads higher than 150 watts Please contact your local dealer or customer assistance for the proper cord for direct to battery connections CAUTION Reverse polarity connections positiv...

Страница 8: ...tt hours of energy consumption power x operating time using the average power consumption and the total estimated running time in hours Power x Operating Time Watt Hours 4 Divide the watt hours by ten 10 to determine how many power supply s 12 volt ampere hours will be consumed 11 Nothing comes close to a Cobra 10 English Turning Your Inverter On or Off Be sure to have your power inverter properly...

Страница 9: ...mentarily then the inverter will shutdown The inverter will continue to check for appropriate temperature levels while trying to restart the load NOTE A momentary sound of the internal alarm and or flash of the red light is normal at start up Power Protection Indicators Operation Operating Limits Operation Operating Limits Power Output The inverter can deliver 400 watts for about 60 minutes The in...

Страница 10: ...ove 12V To extend the life of the fan it will stop when there is no load The speed of the fan increases as the load increases The unit is completely insulated in input and output for added safety Problem Symptom Low output voltage No output voltage No output voltage after prolonged use No output voltage Protect indicator lighted No output voltage No power to inverter Low battery alarm on all the t...

Страница 11: ...tact your local dealer for warranty information Maintenance Very little maintenance is required to keep the inverter operating properly The exterior of the unit should be cleaned periodically with a damp cloth to prevent accumulation of dust and dirt At the same time tighten the screws on the DC input terminals Be sure vents and fans are free of dust or debris Product Service If you have any quest...

Страница 12: ...s Radar Laser Detectors Safety Alert Traffic Warning Systems Accessories GPS Global Positioning System HighGear Accessories Name Address No P O Boxes City State Province Zip Country Telephone Credit Card Number Type Visa Mastercard Discover Exp Date Customer Signature Item U S Cost Each Qty Amount U S Subtotal Tax if Applicable Shipping Handling Total Amount Shipping Handling 10 00 or less 3 00 10...

Отзывы: