Nothing comes close to a Cobra

®

Specifications

Operation

Specifications

Continuous output power (1 hour) . . . . . . . . . . . 2500W
Surge rating (0.1 second) . . . . . . . . . . . . . . . . . . 5000W
Peak efficiency (12V – 1⁄2 load) . . . . . . . . . . . . . . > 88%
Efficiency (full load, 12V) . . . . . . . . . . . . . . . . . . . > 83%
No load current draw . . . . . . . . . . . . . . . . < 0.5A (12.6V)
Output waveform (resistive load) . . . Modified sine wave
Output frequency . . . . . . . . . . . . . . . . . . . . 58HZ – 62HZ
Output voltage . . . . . . . . . . . . . . . . . . . . . . 109V – 120V
Input voltage . . . . . . . . . . . . . . . . . . 10.4VDC – 14.4VDC
Alarm voltage (unload) . . . . . . . . . . . . . . .10.2V – 10.8V
Shutdown voltage (unload) . . . . . . . . . . . . . 9.2V – 9.8V
Operating temperature range . . . . . . . . . . . . 0°C – 40°C

(32°F – 104°F)

Storage temperature range . . . . . . . . . . . . -40°C – 85°C

(-40°F – 185°F)

Protection . . . . . . . . . .Overload, short-circuit, overtemp,

reverse polarity, under/over voltage

Notes

All protection is automatically recovered.

To protect the battery, if the unit needs to be restarted
after low voltage protection, the voltage of DC input
should be above 12V.

To extend the life of the fan, it will stop when there is no
load. The speed of the fan increases as the load increases.

The unit is completely insulated in input and output for
added safety.

18 English

Troubleshooting Guide

Operation

Problem/Symptom

Low output voltage

No output voltage

No output voltage
after prolonged use

No output voltage,
“Protect” indicator
lighted

No output voltage

No output voltage

Low battery alarm
on all the time

Possible Causes

Overload

Low input voltage

Thermal
shutdown

High input
voltage

Short circuit

Inverter
switched off

No power
to inverter

Reverse
DC polarity

Poor DC wiring

Poor battery
condition

Solution

Reduce the load.

Recharge battery.
Check connections
and cable.

Allow inverter
to cool off.

Reduce load,
continuous
operation input
current required.

Improve ventilation;
Make sure ventilation
openings in the
inverter are not
obstructed.

Reduce ambient
temperature.

Make sure
the inverter is
connected to
12V battery.

Check regulation
of charging system.

Check load for
proper operation.

Turn inverter on.

Check wiring
to inverter.

Observe
correct polarity.

Check
connections.

Make sure battery
is fully charged.

Troubleshooting Guide

All manuals and user guides at all-guides.com

Содержание CPI 2550

Страница 1: ...Help Desk English only 24 hours a day 7 days a week 773 889 3087 phone Customer Assistance Operators English and Spanish 8 00 a m to 6 00 p m CT Monday through Friday except holidays 773 889 3087 phon...

Страница 2: ...tomer Assistance A1 Product Features A2 Important Safety Information 1 Quick Evaluation Before Installation 4 Installation Installation Requirements 6 Mounting 7 Connecting Cables 8 Power Consumption...

Страница 3: ...ipment WARNING Statements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compartment where gas and battery...

Страница 4: ...d power tools These chargers have a WARNING label stating that dangerous voltages are present at the battery terminals This problem does not occur with the vast majority of battery operated equipment...

Страница 5: ...he inverter when drawing current from the power source If the cable suffers an excessive voltage drop the inverter may shut down when drawing higher currents because the voltage at the inverter droppe...

Страница 6: ...requirements A Dry Do not place in an area where water can drip or splash on the inverter B Cool Ambient air temperature should be between 30 F and 105 F 0 C and 40 C The cooler the better C Ventilate...

Страница 7: ...Use only copper wire Aluminum wire has about one third more resistance than copper wire of the same size plus it is difficult to make good low resistance connections to aluminum wire We recommend two...

Страница 8: ...inverter and another AC source such as a generator or utility power to the AC wiring at the same time The inverter will be damaged if its output is connected to AC voltage from another source Damage...

Страница 9: ...power source such as a generator or the utility line WARNING You may observe a spark when making the connection because current can flow to charge the capacitors in the inverter Do not make this conne...

Страница 10: ...piece of equipment will be running between battery charging cycles 3 Calculate the total watt hours of energy consumption power x operating time using the average power consumption and the total estim...

Страница 11: ...power inverter off 1 On the left side panel switch the On Off Switch to off NOTE The On Off Switch turns the control circuit in the inverter on and off It does not disconnect power from the inverter...

Страница 12: ...ncreases The unit is completely insulated in input and output for added safety 18 English Troubleshooting Guide Operation Problem Symptom Low output voltage No output voltage No output voltage after p...

Страница 13: ...mited Two Year Warranty For Products Purchased in the U S A Cobra Electronics Corporation warrants that its Cobra power inverter and the component parts thereof will be free of defects in workmanship...

Страница 14: ...onics Attn Accessories Dept 6500 West Cortland Street Chicago IL 60707 USA To order online please visit our website www cobra com Amount Shipping Handling 10 00 or less 3 00 10 01 25 00 5 50 25 01 50...

Страница 15: ...25 Nothing comes close to a Cobra 24 English All manuals and user guides at all guides com...

Отзывы: