Chapter 3: Connect the system
34
Connect power
3.4.2.2 SAILOR 6194
The SAILOR 6194, like the SAILOR 3027, connects to power through the
CAN interface, which in the SAILOR 6194 is a group of spring-loaded
terminals (X2). Refer to
SAILOR 6194 Terminal Control Unit, Installation
Do not connect the shield of the CAN cable to the SAILOR 6194.
3.4.3 Under-voltage protection (UVP)
If the power source is a battery, you must configure the SAILOR 3027 and
the SAILOR 6194 to the correct under-voltage protection.
Configure the under-voltage protection as follows:
1. Connect a computer to the SAILOR 6194 and start a terminal program
as described in
2. At the
tt6194:/$
prompt, type in the relevant command
depending on the voltage of the battery.
• Disable UVP: Type
avr_uvp 0
• 24 V: Type
avr_uvp 1
• 12 V: Type
avr_uvp 2
• CAN voltage: Type
avr_uvp 3
3. Type
minic
to access the SAILOR 3027.
4. At the
Can0:/$
prompt, type
SU SYSADM
and enter the password.
5. Type in the relevant command from step 2, depending of the voltage of
the battery.
Caution!
The battery may be damaged if the correct under-
voltage protection is not applied!
Содержание SAILOR 6120
Страница 1: ...SAILOR 6120 30 40 50 Installation manual...
Страница 2: ......
Страница 3: ...i SAILOR 6120 30 40 50 Installation manual Document number 98 154541 A Release date November 15 2017...
Страница 12: ...List of tables x...
Страница 31: ...Chapter 2 Install the system Install the SAILOR 3027 19 2222 Install the system Vertical pole Horizontal pole...
Страница 96: ...Chapter 5 Installation check and test 84 Test the system with SAILOR 6018...
Страница 116: ...98 154541 A www cobham com satcom...