MBF-40 SMR900 PS REPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
Cobham Wireless
–
Coverage
Date: 31-May-18
www.cobham.com/wireless
Doc. No. 00141UM
Rev. 1.0
Page |
36
3.3.3 RF Balancing
The MBF-40 RF Balancing procedure can be performed manually (the automatic option specified in section
3.3.3.2 will be available in the future) via the OMU II web interface.
3.3.3.1 Manual RF Balancing
NOTE: If connected locally, enter the MBF-40 Home screen and skip to step 2.
The manual balancing procedure consists of the following steps:
•
Verifying the DL RF output level is maximized by setting the required DL attenuation of the signal.
•
Setting the UL attenuation according to the DL.
•
In case of noise, adjusting the UL attenuation to reduce noise
To balance the MBF-40 UL and DL outputs
1. Access the MBF-40 Configuration window:
•
Click on the Nodes button. The below pane appears
•
Click Control next to the node to be balanced.
Figure 3-8. OMU Node Screen
Содержание MBF-40 Americas