![COBHAM 407006D-00500 Скачать руководство пользователя страница 91](http://html1.mh-extra.com/html/cobham/407006d-00500/407006d-00500_installation-and-operation-manual_2629886091.webp)
Software update
98-166784-A
Chapter 8: Service
8-9
8888
Serv
ice
Software recovery procedure (SAFE MODE)
To recover from a failed software upload, turn off the ACU and turn it on again. Then repeat
the upload procedure as described in
on page 8-8. If this does not help
use the following recovery procedure:
1. Switch off the ACU.
2. Press and hold down the arrow keys
and
on the keypad.
3. Switch the ACU on and wait for the display to show with a small font size
SAFE MODE
in the top left corner.
4. Release the arrow keys
and
.
5. Connect a PC to LAN port 3 of the ACU.
6. Set the IP address of the PC to static: IP:192.168.0.2, Subnet: 255.255.255.0
7. Open an Internet browser and type http://192.168.0.1 (Default IP address of the ACU)
8. Click
Browse...
and locate the software file.
9. Click
Upload
.
The upload procedure takes a couple of minutes. When done, the ACU automatically
restarts with the new software version.
Figure 8-5: Recovery procedure after failed software upload
Figure 8-6: Upload software to terminal (Safe mode)
Important
Do not browse away from the upload page. This will terminate the
upload process. Wait for the browser to reload automatically.