1
BBG-1002-UDX-FS Functional Description
1-14
BBG-1002-UDX-FS PRODUCT MANUAL
BBG-1002-UDX-FS-OM (V1.0)
GPO Interface
Two independent phototransistor non-referenced (floating) contact pairs
(
GPO 1/1
and
GPO 2/2
) are available. A GPO can be invoked by setting a GPO
to be enabled when a preset is in turn applied (i.e., when a preset is invoked
(either manually or via event-based loading), the GPO is correspondingly also
activated.
Serial (COMM) Ports
The BBG-1002-UDX-FS is equipped with two, 3-wire serial ports (
COM 1 -
Serial Port 1
,
COM 2 - Serial Port 2
). The ports provide for SMPTE 2020
de-embedding to an output port, and provide RS-485 LTC I/O (when licensed
with option
+LTC
). Either port can be configured as RS-232 Tx/Rx or
RS-4585 non-duplexed Tx or Rx.
+SCTE104 Insertion
Note:
Option +SCTE104 is available only for Path1.
SCTE104 provides generation and insertion of SCTE 104 messages
into baseband SDI. Message send can be triggered from automation GPI or
other event action modes. The option can also execute actions based on SCTE
104 messages received, as well as send triggered SCTE 104 packets to other
downstream systems.
The user interface is based on common SCTE 104 operations: Splice Start
Normal, Splice Start Intermediate, Splice End Normal, Splice End
Intermediate, and Splice Cancel (splice_request_data variants), offering full
control of splice start, end, and cancel as well as pre-roll and break duration
offsets. (A Manual Supplement is planned for this option. Please check
product web page.)
Alarm Function
The unit can be set to monitor input video/audio for input errors such as input
LOS, frozen or black frame, loss of reference, closed captioning ancillary data
loss, and/or per-channel audio absences. These alarms can be propagated as a
general error or warning message, and can be downloaded as basic .txt logs or
via a Syslog function.
User setup tables configure the alarm severity escalation as well as trigger
holdoff/release and other thresholds as applicable.
User Control Interface
BBG-1002-UDX-FS uses an HTML5 internal web server for control/
monitoring communication, which allows control via a web interface with no
special or unique application on the client device. Connection to the device to
the network media connection is via a standard 10/100/1000 RJ-45 Ethernet
connection. The device can also be controlled using DashBoard™ remote
control, where it appears as a frame connection.