Important: Always read and follow operating instructions.
• 27
Maintenance
Standard Maintenance
Routine maintenance according to the following instructions is of crucial importance to ensure the correct
operation and lasting life of the Tire Changer.
Unplug the unit from electrical power source and compressed air supply before servicing it.
Release the compressed air from the circuit by pressing the deflation button
14
for a few seconds.
On daily basis, keep the machine clean of any dirt to ensure the smooth movement of slides,
carriages, and tools and to ensure the correct functioning of clamping chuck and locking systems.
On daily basis, check for worn or damaged plastic mounting tool inserts and plastic and rubber
protections in order to protect alloy rims.
In case of wear or damage, replace them with new inserts and new protections.
On periodical basis, clean the sliding guides of the bead loosener carriage with naphtha and lube them with oil
or proper grease. Perform the same cleaning and lubricating actions on every junction and mechanical slide.
On periodical basis, check the tensioning of clamping chuck rotation driving belt. If necessary, use a 13mm
wrench to loosen the mounting bolts of the motor support plate, then adjust the belt tension by turning the
tensioning screw and retighten the mounting bolts.
Every 2-3 days, check the oil
dropping into the cup (1 drop
every 4-5 activations of the bead
pressing arm or of the bead
loosening system). If necessary,
turn the screw on the top of the
cup with a screwdriver.
For long lasting correct
functioning of the pressure
limiter device, check on
regular basis and discharge
the condensation when
needed.
Periodically check the oil lev-
el which should be kept above
the container trasparent part.
If necessary, unscrew the cup
and topoff by adding oil for
pneumatic systems.
(Chevron Regal
®
R&O 32)
If necessary, drain the
condensation by turning the
drain tap clockwise (keep
the pneumatic supply ON to
perform this adjustment).
On monthly basis, unplug
the machine from pneu-
matic supply and remove
the filter cup to clean it of
possible solid impurities.