OWNER’S MANUAL
2021
24
SYMPTOM
PROBABLE CAUSE
RECOMMENDED ACTION
Noisy/Loud motor
•
Air trapped in the pump
•
Low water level
•
Worn pump seal
•
Defective pump
>
Open bleed valve in the
skimmer
>
Add water to the spa
>
Contact your Dealer
>
Contact your Dealer
Pumps power down on their own
•
Set temperature has been reached
•
Filtration cycle has ended
•
Automatic time out
•
Overheat safety protection
>
No problem
>
No problem
>
Pumps are set to run for a predetermined time
while the spa is in use (15-20 Mins)
>
The pumps have a thermal overload which will
prevent them from running for extended periods
of time. Wait until pumps have cooled down (1+
hrs). If problem persists, contact your Dealer.
Pump running constantly, will not
turn off
•
Filter cycle set to 24 hours
•
Problem with the circuit board
>
Turn off 24 hour filtration
>
Turn power off at GFCI and contact your Dealer
Pump will not turn on
•
GFCI tripped
•
Motor has overheated
•
Not plugged in
•
Damaged plug
•
Seized motor
•
Blown fuse
•
Motor vent is blocked
>
Reset the GFCI
>
Let cool for 1+ hour
>
Plug in to the board
>
Contact your Dealer
>
Contact your Dealer
>
Check fuse or contact your
Dealer
>
Clear debris from the vent
SYMPTOM
PROBABLE CAUSE
RECOMMENDED ACTION
Spa does not work
•
Power is turned off
>
Reset GFCI
No display on the control panel
•
Power is turned off
•
Defective topside control
>
Reset GFCI
>
Contact your Dealer
Letters on the control panel
•
An error has been found
>
Refer to the Reference Card for your control panel
to verify the error. Contact your Dealer for service
SPA SYSTEM
PUMP PROBLEMS
TROUBLESHOOTING GUIDE
TRADITIONAL SPAS
Содержание TRADITIONAL APEX
Страница 2: ...OWNER S MANUAL 2021 2 TRADITIONAL SPAS ...
Страница 66: ...WORLD S BEST BUILT SPAS ...