background image

Heater  Voltage  (Feature  not  used  on  CE  rated 
systems.) 

Displays the operating voltage configured for the heater. 

Heater Wattage as Configured in Software  

Displays a heater kilowatt rating as programmed into the 
control system software (1-3 or 3-6). 

H _ (Heater Type)

 

Displays a heater type ID number. 

SW _ (Dip Switch Settings) 

Displays  a  number  that  represents  the  DIP  switch 
positions of S1 on the main circuit board. 

PANL (Panel Version) 

Displays  a  number  of  the  software  in  the  topside  control 
panel. 

Additional  Utilities, 

While  “INFO  is  on  the  LCD  press 

the Light button and GFCI should appear on the screen. 
You  can  use  the  Warm  or  Cool  button  to  toggle  the 
selection on the screen or the Light button to move to the 
next menu option, option are listed below. When finished 
use the light button to save your selection. 

GFCI (GFCI Test) 

GFCI Test is not always enabled, so it may not appear. 

A / B (A/B Sensor Temperatures) 

When  this  is  set  to  On,  the  temperature  display  will 
alternate  to  display  temperature  from  Sensor  A  and 
Sensor B in the heater. 

FALT LOG (Fault Log) 

The Fault Log is a record of the last 24 faults that can be 
reviewed by a service tech. 

DEMO (Demo Mode) 

Demo Mode is not always enabled, so it may not appear. 

Patio—6 Button Topside Upgrade 

2021 

Содержание Patio

Страница 1: ...e on The device will turn off after 15 minutes If the secondary device on your hot tub is an additional Jet Pump when you press the button to activate the pump it will be on Low Speed Press the button again to activate High Speed Press once again to turn Off Light Press Light to operate the spa light Turns off after 4 hours If your hot tub is equipped with a multicolor lighting package then pressi...

Страница 2: ...ay is not actually programmed due to a power cycle SET TIME will appear in the menu instead of just TIME Flip Invert Display To set press the Warm or Cool button While the Temperature is still flashing press Light repeatedly until FLIP appears in the LCD Once FLIP is on the screen use the Warm or Cool buttons to change the screen Press the Light button to save the selected option Restricting Opera...

Страница 3: ...on When set to 0 no addressing is used Use this setting for a Dolphin Remote which is factory set for no address by default When set between 1 and 7 the number is the address See the Dolphin manual for details Utilities and Information To enter Utilities and Information press the Warm or Cool button While the Temperature is still flashing press Light repeatedly until UTIL appears in the LCD Use th...

Страница 4: ...INFO is on the LCD press the Light button and GFCI should appear on the screen You can use the Warm or Cool button to toggle the selection on the screen or the Light button to move to the next menu option option are listed below When finished use the light button to save your selection GFCI GFCI Test GFCI Test is not always enabled so it may not appear A B A B Sensor Temperatures When this is set ...

Отзывы: