background image

5

!

PLEASE READ YOUR ENTIRE OWNER’S MANUAL BEFORE SPA OPERATION

Basic Information 

Water Care 

IMPORTANT: 

Caring  for  your  water  by  ensuring  proper 

chemical usage is the single most important  thing  you 

can do to keep your 

Patio

 Spa in good condition. 

WARNING

: Improper chemical usage and maintenance will 

quickly  lead  to  severe  issues  with  your  spa  and  can  effect 
the spa equipment, jets, pumps, and all other components in 
contact with the spa water. 

All Patio Spas are susceptible 

to damage from unbalanced spa water. 

Always  maintain  your  water  chemistry  within  the  following 

parameters. 

pH 

7.2 - 7.8 

Chlorine 

1.0 - 3.0 ppm 

Bromine 

2.0 - 5.0 ppm 

Total Alkalinity 

100 - 120 ppm 

Calcium Hardness 

150 - 250 ppm 

Electrical 

All self contained spas use 120VAC or 240VAC electrical spa packs. 

120VAC: 

requires  an  isolated  15  Amp  circuit  breaker, an 

isolated  circuit  with  no  other  appliances  or  lights  on  the 

circuit  at  any  time.  Extension  cords  are  not  to  be  used  in 

conjunction  with  the  operations  of  the  spa.  Low  voltage 

damage could result and this is not covered under warranty.

IMPORTANT: 

Patio

  Spas  with  110V  means  that  the 

jets and heater will not work at the same time. 

NOTE:  All  components  must  be  120V.  No  240V 
components allowable. 

240VAC: 

Depending  on  the  model  of  the  spa,  it  will 

require  either  a  40,  50,  or  60  Amp  dedicated  circuit 

breaker with the proper wire size (gauge) based on the 

length of the run.

 

The electrical circuit must be installed by a certified 

electrician and approved by a local building or electrical 

inspector. 

Surface 

Transport 

Your new spa has left the factory cleaned and polished  and ready to begin operation  after passing our many  quality and operational 
tests. However, depending on your location in the world, your spa may have spen

t

 days or even weeks in transit before arriving at your 

home.  Please  ensure  that  before  filling  or  operating  your 

Patio

  Spa  that  you  check  all  electrical  and  plumbing  connections are 

securely connected in the equipment area as they might have loosened during shipping. If any dirt has accumulated, you will want to 
remove with a clean cloth or sponge using warm water.

Your new portable spa must be placed on a firm, flat, and level surface, so that the weight is supported uniformly. We recommend no 

less than a 3” (93 mm) thick concrete slab. Wood decking or balconies must be constructed to support 150 pounds per square foot 

(730 kg/m

2

). Refer to the local and current building codes in your area. Should your new spa need to go through the gate or space  –

restricted area, ensure you’ve communicated those limitations with your dealer to avoid delivery complications.

NOTE: 

Damage caused by alternate decking methods  may avoid the spa warranty. Contact your dealer if you have any questions 

regarding spa location and placement.

!

!

OWNER’S MANUAL

 

OWNER’S MANUAL 

2022

 

PATIO

 S

ERIES

Содержание Patio Element Bench

Страница 1: ...2022 PATIO SERIES Coast Spas Manufacturing 6315 202 Street Langley BC Canada 604 514 8111 info coastspas com www coastspas com OMEGA ELEMENT ...

Страница 2: ...OWNER S MANUAL 2022 2 PATIO SERIES ...

Страница 3: ...ained professionals who can assist you with spa parts setup operations maintenance and technical support DISCLAIMER At the time of print this manual is accurate in its information Coast Spas reserves all the rights to change modify any spa designs and or features without notification To check on updates or for other information please visit www coastspas com CONGRATULATIONS YOU RE ALMOST READY TO ...

Страница 4: ...e 16 17 Patio Spa Maintenance Procedures Page 17 19 Water Clarity Troubleshooting Page 20 Troubleshooting Guide Page 21 22 Draining Winterizing Page 23 Patio Spa Controls Page 24 25 Patio Spa Jet Operations Page 26 31 Patio Spa Specifications Page 32 Balboa Wi Fi module Page 33 Del Ozone operation Page 34 Patio Spa Service Log Page 35 36 IMPORTANT GFCI INFORMATION Based on the testing conducted by...

Страница 5: ...ated circuit breaker with the proper wire size gauge based on the length of the run The electrical circuit must be installed by a certified electrician and approved by a local building or electrical inspector Surface Transport Your new spa has left the factory cleaned and polished and ready to begin operation after passing our many quality and operational tests However depending on your location i...

Страница 6: ...er exceed 104 F 40 C Water temperatures between 100 F 38 C and 104 F 40 C are considered safe for a healthy adult Lower water temperatures are recommended for young children and when Patio Spa use exceeds 10 minutes Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should limit Patio Spa water ...

Страница 7: ...Patio Spa and keep the Patio Spa cover secure in high wind conditions There is no representation that the cover clip tie downs or actual locks will prevent access to the Patio Spa CAUTION For exercise the water should not exceed 90 F 32 C AIR CONTROL Mounted generally on the lip of the spa it induces warm air from the equipment enclosure into the jet stream through venturi action WATER DIVERTER Th...

Страница 8: ...t jet designed for foot and leg massage LAMINAR FLOW A thin stream of water that arcs from the spa lip PREPARATION SET UP AND LOCATION FOR YOUR NEW SPA You want to keep in mind how you intend to use the spa and plan the location accordingly How close is the spa from the exit or entrance to your house consider the cold weather Is the path to your spa clean of debris sand grass so as not to track in...

Страница 9: ...er Jets 8 Neck Jets 9 Control Panel 10 Volcano Jet 11 Spa Drain 12 Spa Lights 13 Suction 14 3 Spa Light 15 Skimmer 10 12 13 DISCLAIMER At the time of print this manual is accurate in its information Coast Spas reserves all the rights to change modify any spa designs and or features without notification To check on updates or for other information please visit www coastspas com OWNER S MANUAL 2022 ...

Страница 10: ...ation Coast Spas reserves all the rights to change modify any spa designs and or features without notification To check on updates or for other information please visit www coastspas com Patio Omega Bench Patio Omega Bench ULP Patio Omega Lounge Patio Omega Lounge ULP OWNER S MANUAL 2022 PATIO SERIES ...

Страница 11: ...ccurate in its information Coast Spas reserves all the rights to change modify any spa designs and or features without notification To check on updates or for other information please visit www coastspas com Patio Element Bench Patio Element Lounge OWNER S MANUAL 2022 PATIO SERIES ...

Страница 12: ...he tension in your muscles Plug and Tub Powered by 110v Household Outlet North America Plug your Hot Tub into a standard household 110V outlet in North America Built in GFCI Ground Fault Circuit Interrupter No need to install dedicated wiring simply fill with water plug in and turn on Portable and perfect for areas that no other spa can go SPA COMFORTS Plush Headrests Beverage Holders Anti Slip Te...

Страница 13: ... when filling FILLING YOUR SPA DO NOT USEHOT WATERTO FILL YOUR SPA DO NOT USEWATER FROM A WATER SOFTENER Place fill hose into open filter canister When filled allmassage jets andfill hot tub until water is2 3 of the way up the skimmer opening excluding neck jets should be under water POWERING UP YOUR SPA Turnpower onatthemainbreaker press twice PUMPl Turn pump 1 on high speed for 20 secondsby pres...

Страница 14: ...stall the pillow you will align the pillow plug with the receptacle Press hit the front side of the pillow firmly which will insert the plug back into the receptacle Proper water chemistry must be maintained Your Patio Spa pillows are easily and quickly damaged when exposed to unbalanced spa water If you suspect that your chemicals may be unbalanced remove your pillows immediately until the water ...

Страница 15: ...internal sewn reinforcing and careful workmanship can only go so far against the ravages of Mother Nature See the specific Warranty card enclosed with your cover for further details When you shock your spa you need to remove the cover for a minimum of 30 minutes to ensure that the chemical gas off can escape from the spa You are required to keep the spa covered at all time when not in use to prote...

Страница 16: ...ents must be 120V No 240V components allowable 240VAC Depending on the model of spa it will require either a 40 Amp 50 Amp or 60 Amp dedicated circuit breaker GFCI with the proper wire size based on the length of the run The electrical circuit must be installed by a certified electrician and approved by a local building or electrical inspector Use minimum 6AWG copper conductors only Torque field c...

Страница 17: ...D FILTERS Turn power OFF at the breaker Loosen air relief valve then remove retainer ring Pull filter lid straight up to remove Do not twist or pull the filter lid up on an angle This could cause damage to the filter canister especially in freezing conditions Remove filter cartridge and clean with a garden hose and a high pressure nozzle Periodically you may need to soak your filter in a cartridge...

Страница 18: ...hloric acids or Muriatic acid to balance the pH as it could severely damage the spa shell Sanitizer Chlorine or Bromine To destroy bacteria and organic compounds in the Patio Spa water by breaking them down into non harmful levels which get filtered out A sanitizer must be used regularly either chlorine or bromine Sanitizing your spa water is the most important spa maintenance you can do for yours...

Страница 19: ...g It is the responsibility of the customer to regularly perform the maintenance procedures To clean and maintain optimum jet functions follow the maintenance instructions below LAMINAR FLOW JET MAINTENANCE INSTRUCTIONS 1 Rotate counter clock wise and pull out the jet body Picture 1a and 1b 2 Using clean piece of cloth remove the dust particles or debris Picture 2 3 Remove the unreachable debris wi...

Страница 20: ...H is too low High metal content in water Adjust alkalinity Adjust pH Use stain and scale product Cloudy Water Poor filtration pH is too high Hardness is too high Total alkalinity is too high Suspended particles Clean filter cartridge Adjust pH Adjust hardness Adjust total alkalinity Drain and refill spa water Algae Growth pH is too high Sanitizer is too low Adjust pH Shock spa with sanitizer Adjus...

Страница 21: ...l not turn off Filter cycle set to 24 hours Problem with the circuit board Turn off 24 hour filtration Turn power off at GFCI and contact your Dealer Pump will not turn on GFCI tripped Motor has overheated Not plugged in Damaged plug Seized motor Blown fuse Motor vent is blocked Reset the GFCI Let cool for 1 hour Plug in to the board Contact your Dealer Contact your Dealer Check fuse or contact yo...

Страница 22: ...ther cold wind Hot tub is wired for 110V and jets are on Put cover back onto hot tub and allow for heat to regenerate Call your dealer if temperature does not increase Hot tubs wired for 110V only have enough power to heat or operate pumps Turn off jets to power heater PUMPS WILL NOT PRIME PROBABLE CAUSE RECOMMENDED ACTION Pump on but no water flow Air trapped in pump No water in the pump Closed v...

Страница 23: ...edures if you are not completely comfortable with them Ensure that you have fully drained the spa Refer to the DRAINING YOUR SPA section After draining your spa may still have water remaining in the equipment and plumbing fittings Disconnect the hand tightened union fittings going to and from the jet pumps Be careful not to lose the O rings between the unions and pump housing Leave drain valve in ...

Страница 24: ...from the panel however you will still be able to control the high speed setting The ozone generator if installed will activate anytime low speed is running AUX PUMP 2 If an additional pump or blower is installed Press Aux to turn the device on If your additional device is a dual speed pump pressing Aux again will activate the pumps high speed Pressing Aux again will turn off the device pump LIGHT ...

Страница 25: ...on If flashing by itself spa is shut down If the problem persists contact your dealer or service organization HL A significant difference between temperature sensors has been detected This could indicate a flow problem If the water level is normal make sure all pumps have been primed If problem persists contact your dealer or service organization LF Persistent low flow problems Displays on the fif...

Страница 26: ...To check on updates or for other information please visit www coastspas com 3 7 2 SPA JET OPERATIONS 3 7 2 OMEGA BENCH JETS PUMP 1 Air Control General Note ON OFF BLUE ORANGE JET Note Ø R 2K 2KV C J Cluster Jet Poly Jet Storm Jet Volcano Jet Carousel Jet Optional L F Shutoff C C Shutoff ON OFF BLUE ORANGE OWNER S MANUAL 2022 Orange Right Blue Left Wall Diverter Control PATIO SERIES ...

Страница 27: ...atures without notification To check on updates or for other information please visit www coastspas com 3 7 2 SPA JET OPERATIONS 3 7 2 OMEGA BENCH JETS ULTRA LOW PRO PUMP 1 Orange Right Blue Left Wall Diverter Control Air Control General Note ON OFF BLUE ORANGE JET Note Ø R 2K 2KV Cluster Jet Poly Jet Storm Jet Volcano Jet Optional L F Shutoff ON OFF BLUE ORANGE PATIO SERIES ...

Страница 28: ... check on updates or for other information please visit www coastspas com PATIO SPA JET OPERATIONS PATIO OMEGA LOUNGE 21 JETS OWNER S MANUAL 2022 PUMP 1 Orange Right Blue Left Wall Diverter Control Air Control General Note ON OFF BLUE ORANGE Optional L F Shutoff C C Shutoff ON OFF BLUE ORANGE JET Note Ø R 2K 2KV C J Cluster Jet Poly Jet Storm Jet Volcano Jet Carousel Jet PATIO SERIES ...

Страница 29: ...ation To check on updates or for other information please visit www coastspas com PATIO SPA JET OPERATIONS PATIO OMEGA LOUNGE 21 JETS ULTRA LOW PRO OWNER S MANUAL 2022 PUMP 1 Orange Right Blue Left Wall Diverter Control Air Control General Note ON OFF BLUE ORANGE Optional L F Shutoff ON OFF BLUE ORANGE JET Note Ø R 2K 2KV Cluster Jet Poly Jet Storm Jet Volcano Jet PATIO SERIES ...

Страница 30: ...ation To check on updates or for other information please visit www coastspas com OWNER S MANUAL 2022 PATIO SPA JET OPERATIONS PATIO ELEMENT BENCH 21 JETS PUMP 1 Orange Right Blue Left Diverter Control JET Note Ø R 2K 2KV C J Cluster Jet Poly Jet Storm Jet Volcano Jet Carousel Jet Optional C C Shutoff ON OFF BLUE ORANGE Air Control General Note ON OFF BLUE ORANGE PATIO SERIES ...

Страница 31: ...ation To check on updates or for other information please visit www coastspas com OWNER S MANUAL 2022 PATIO SPA JET OPERATIONS PATIO ELEMENT LOUNGE 21 JETS Blue Right Orange Left Diverter Control Air Control General Note ON OFF BLUE ORANGE JET Note Ø R 2K 2KV C J Cluster Jet Poly Jet Storm Jet Volcano Jet Carousel Jet Optional C C Shutoff ON OFF BLUE ORANGE PUMP 1 PATIO SERIES ...

Страница 32: ...lbs Patio Element Lounge 5 212 X 212 X 101 5 83 5 X 83 5 X 40 1210 320 420 925 1630 3594 Patio Omega Lounge 4 168 X 212 X 92 66 X 83 5 X 36 890 235 294 647 1184 2610 Patio ULP Omega Lounge 4 167 5 X 212 X 77 66 X 83 5 X 30 845 224 280 617 1125 2480 Series Model Seat Dims cm Dims in Capacity l Capacity us gal Dry Wt kg Dry Wt lbs Wet Weight kg Wet Weight lbs Patio Element Bench 6 212 X 212 X 92 83 ...

Страница 33: ...tings will open the settings menu While connected to the spa will be able to set the temperature change the degrees between F or C alter the heat mode Ready Rest select the temperature range low or high set the time of day input filter cycles time start and duration and have access to the advanced menu For more information on the various settings please refer to the selection in the owner s manual...

Страница 34: ...ycles and pump 1 operation Verify that the green light on the Ozone turns on when activated Check the spa drain at the bottom of the spa to verify that small ozone bubbles are coming out Verify that one way check valve is installed on the ozone tubing and it is working as intended PATIO SERIES ...

Страница 35: ..._________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ ________________________________________________...

Страница 36: ..._________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ ________________________________________________...

Страница 37: ...WORLD S BEST BUILT SPAS ...

Отзывы: