background image

 

 

 

 

 

 

 

 

 

Chlorine Generating Device for Spas 

 

EcoClean 

Coast Spas 

Manufacturing Inc. 

6315 - 202 Street • Langley, BC • V2Y 1N1 

 

DOMESTIC

 

Installation / Operation Manual 

 

PLEASE RETAIN OWNER'S MANUAL FOR FUTURE REFERENCE 

 REGISTRATION NUMBER 27899.02 PEST CONTROL PRODUCTS ACT

Maximum output equivalent to 15 grams of free available chlorine per day.   One  

EcoClean  unit can treat a maximum of 1500 Litres of spa water.  Controls Bacteria 

in Spa Water. 

  EcoClean 

 

 

us

C

 

 

 

Co
as

t S
p

as

 Ma
nuf
act
ur

in

g I
n

c.

 E

co

C

lean
  E
n

gl

is

h

 Ma
nu
al O

ct

 2

0

08 

 IMPORTANT 

READ THE LABEL AND THE INSTALLATION/OPERATION MANUAL BEFORE USING 

Coast Spas Manufacturing Inc. • 6315 - 202 Street • Langley, BC • V2Y 1N1 

Tel: (604) 514-8111 

Содержание EcoClean

Страница 1: ...CTS ACT This cell must only be used on this model of chlorine generating device Read the Label and the Installation and Operation Manual of the chlorine generating device Coast Spas EcoClean unit before using Coast Spas Manufacturing Inc 6315 202 Street Langley BC V2Y 1N1 PHONE 604 514 8111 EcoClean Cell Label ENGLISH Oct 2008 13 DEC 2010 2010 5304 ...

Страница 2: ...uivalent to 15 grams of free available chlorine per day Controls Bacteria in Spa Water Always maintain 3 5 ppm of free available chlorine or bromine in your spa water DOMESTIC READ THE LABEL AND THE INSTRUCTION MANUAL BEFORE USING KEEP OUT OF REACH OF CHILDREN Warning Operating the EcoClean without water flow through the cell can cause a build up of flammable gases which can result in FIRE or EXPL...

Страница 3: ...PEST CONTROL PRODUCTS ACT Maximum output equivalent to 15 grams of free available chlorine per day One EcoClean unit can treat a maximum of 1500 Litres of spa water Controls Bacteria in Spa Water EcoClean us C Coast Spas Manufacturing Inc EcoClean English Manual Oct 2008 IMPORTANT READ THE LABEL AND THE INSTALLATION OPERATION MANUAL BEFORE USING Coast Spas Manufacturing Inc 6315 202 Street Langley...

Страница 4: ...n 1 a System Sizing 3 4 1 b Spa Water Preparation Monitoring 5 6 Section 2 Installation Requirements 2a Power Supply Cell Installation 7 8 2b Equipment Dimensions 9 Section 3 Start Up Operation 3a Power Supply Functions 10 11 3b Start Up Sequence 11 Section 4 Trouble Shooting 4a Trouble Shooting the EcoClean 12 Appendix Service Information 13 ...

Страница 5: ...ectrical outlet 110VAC ONLY 4 WARNING Do not use spas or hot tubs unless all suction grates are installed to prevent body and hair entrapment 5 DANGER To reduce the risk of drowning from hair and body entrapment install suction fittings with a marked flow rate that equals or exceeds the flow rate on the equipment assembly 6 WARNING Install blower no less than 30cm 1 foot above the maximum water le...

Страница 6: ...t use extension cords to connect unit to electric supply provide a properly located outlet 5 Do not bury cord Locate cord to minimize abuse from lawn mowers hedge trimmers and other equipment 6 Warning Operating the EcoClean without water flow through the cell can cause a build up of flammable gases which can result in FIRE or EXPLOSION General Use 1 WARNING To reduce the risk of injury do not per...

Страница 7: ...g 9 Obese persons and persons with a history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a spa hot tub 10 Persons using medication should consult a physician before using a spa or hot tub since some medication may induce drowsiness while other medication may affect heart rate blood pressure and circulation 11 Do not us...

Страница 8: ...l Maximum output equivalent to 15 grams of free available chlorine per 24 hours max dial setting of 100 Reverse Polarity Function The Reverse Polarity Function is designed to automatically clean the cell blades maximizing the cell s ability to manufacture chlorine or bromine This feature is only enabled when the AC power is on and the L E D light displays a solid GREEN color The unit reverses pola...

Страница 9: ...o protect your equipment from excessive levels of sanitizers 3 Cyanuric acid level maintained This chemical when added to your outdoor spa water significantly inhibits sanitizer depletion from exposure to sunlight Cyanuric acid also inhibits corrosion if your spa is equipped with any metal components Minimum levels or better must be maintained to ensure that the sanitizer being produced is protect...

Страница 10: ...on This amount of chlorine could satisfy up to 1 500 L 400 U S gallons of spa water depending on the 8 demand variables for sanitizer NOTE Residual salt levels must be maintained above 2800 ppm and below 3200 ppm Do not exceed 3200 ppm salt residual if you object to salty tasting water Normal System Sizing Guide The sizing criteria below reflects normal conditions based on field experience and pro...

Страница 11: ...n the next page Before adding salt to a spa hot tub for the first time turn your EcoClean unit OFF then pour salt around the perimeter of the spa NOTE Homeowners with water softening treatment equipment which utilize salt may already have sub stantial levels of salt in their drinking water So before adding this water to your spa test the level of salt then determine the amount of salt still needed...

Страница 12: ... to add Note Indoor or bromine spas do not require the addition of CYA Cyanuric Acid Needed for 75 PPM Section 1 b 6 POUNDS OF SALT NEEDED FOR 3000 PPM RESIDUAL Salt Level Tub Volume in U S Gallons Before Addition 100 200 300 400 0 ppm 2 5 5 0 7 5 10 0 300 ppm 2 3 4 5 6 8 9 0 600 ppm 2 0 4 0 6 0 8 0 900 ppm 1 7 3 5 5 3 7 0 1200 ppm 1 5 3 0 4 5 6 0 1600 ppm 1 2 2 4 3 5 4 7 1900 ppm 93 1 9 2 8 3 7 2...

Страница 13: ... the wall installation The cell should be placed into the footwell of the spa Diagram 1 Where the EcoClean unit is a factory installed option the cell will be mounted into a standard spa fitting and installed directly into the wall of the spa The in wall model includes a DC cell cord with spade connectors to allow for future servicing of the power supply Diagram 2 7 UNIT WITH CELL ATTACHED FOR OVE...

Страница 14: ...Section 2 a Power Supply and Cell Installation Continued Diagram 2 SPADE CONNECTORS TO DC CABLE CELL BLADES SPA WALL Model C1 IW Cell UNIT WITH IN WALL FACTORY INSTALLED CELL 8 ...

Страница 15: ...Dimensions Power Supply and Cell AC PLUG ALWAYS PLUG INTO GFCI RECEPTACLE DC CELL CABLE L E D INDICATOR FEED RATE DIAL 0 100 END CAPS BODY COVER CELL BLADES POWER SUPPLY C E L L Section 2 b 9 ...

Страница 16: ...ent problem or failure For further explanation of this indicator please refer to the Trouble Shooting Guide beginning on page 12 Output Control The Output Control Dial is a percentage timer that regulates the amount of on time the system requires to maintain the chlorine bromine residuals as indicated on page 4 of this manual The output is regulated according to the setting of this dial Remember t...

Страница 17: ...ion 3 a EcoClean Power Supply Functions Cont d Equipment Start up Sequence Before operating the EcoClean System perform the following steps to ensure proper installation and opera tion A Turn ON all circuit breakers to the spa equipment Turn on jet pump Add required type s and amount of salt to spa Broadcast over the surface and allow salt to COMPLETELY dissolve 15 20 minutes Place the cell in the...

Страница 18: ...Calculate Langelier s Index to assure balanced water See page 5 alkalinity and calcium hardness Adjust the water chemistry and mix 1 part muriatic acid to 4 parts water Allow the cell to soak in this solution for no longer than 15 minutes Repeat if necessary Rinse with fresh water and re install Dilute spa water with fresh water if necessary 2 Scale build up within the cell E Low salt E Check the ...

Страница 19: ...urchase Warranty service cannot be performed without this documentation WHEN CALLING FOR SERVICE Please have the following information ready 1 Power Supply Model _________________________________________ 2 Chlorine Cell Serial Number ___________________________________ Located on top of cell stamped in plastic 3 Installation Date MM ___________DD _________YY ______________ 4 Warranty Registration ...

Страница 20: ...formation This service and this information do not replace the official hard copy label The PMRA does not provide any guarantee or assurance that the information obtained through this service is accurate current or correct and is therefore not liable for any loss resulting directly or indirectly from reliance upon this service ...

Отзывы: